apex Elemental Scientific High Efficiency Sample Inlet System
Transcription
apex Elemental Scientific High Efficiency Sample Inlet System
Elemental Scientific apex High Efficiency Sample Inlet System The apex enhances sensitivity by increasing sample transport efficiency and improving the quality of aerosol introduced to the ICP instrument. Liquid samples are nebulized with the PFA MicroFlow nebulizer into a heated cyclonic spray chamber and desolvated by a Peltier cooled condenser. This gives unsurpassed stability and sensitivity. Increases sensitivity up to 10x, depending upon sample flow rate Quartz or PFA Teflon flow path Uses PFA MicroFlow Nebulizers from 10 to 700 µL/min Improves transport efficiency Enhances signal stablility 60000000 Optional membrane desolvation 50000000 Rapid rinse out, over 6 orders of magnitude rinse out of 238U in 60 seconds Intensity Fast rinse-out 40000000 30000000 20000000 10000000 10ppb 238U Rinse out 0 Li 7 Std. Inlet 100µL/min 3 orders in 20s 5 orders in 60s 10ppq Background Elemental Scientific Inc. 2440 Cuming St. Omaha, NE 68131 USA www.elementalscientific.com Phone: 402.991.7800 Fax: 402.991.7799 Email: esi@icpms.com Co 59 In 115 Ce 140 Apex 100µL/min U 238 Ba 138 Apex 480µL/min The apex Q is over 90% efficient at transporting the sample analyte to the plasma There are 4 apex models: apex E – Low cost unit designed primarily for ICP Emission systems. apex Q – An o-ring-free Quartz flow path gives high sensitivity and low background. apex IR – An additional mixing chamber enhances signal stability for Isotope Ratio analysis. apex HF – A high-purity PFA Teflon flow path gives resistance to HydroFluoric acid. Performance Arsenic Lead Wavelength scans from a radial ICP-OES of 10ppm solution of Arsenic and Lead introduced with both standard cyclonic spray chamber and the apex E sample inlet system. Standard Error (abs.) x 10-6 Sr Ratios SIS/PFA-50 (NBS 987) apex IR/PFA-100 200 ppb 10 ppb 100 ppb 84 Sr/86Sr* 15.3 25.8 2.8 87 Sr/86Sr* 3.9 7.8 2.7 123 111 49.8 88 Sr/86Sr *Ratio normalized to 88Sr/86Sr Thermo Neptune Sensitivity comparison (1µg/L) apex HF vs. Crossflow Nebulizer Elan DRC II CrossFlow apex HF Mg (24) In (115) Ba (138) Ce (140) Pb (208) 10091 27470 26366 21499 12885 207329 265083 302756 246960 Optional Membrane Desolvation The addition of the ACM or Spiro can further dramatically reduce the amount of water vapor in the aerosol, reducing oxide interferences. Reduced Oxides 4 1 0.5 ACM Module Elemental Scientific Inc. 2440 Cuming St. Omaha, NE 68131 USA www.elementalscientific.com Phone: 402.991.7800 Fax: 402.991.7799 Email: esi@icpms.com Standard Scott Apex Apex + ACM Apex + Spiro 3.5 3 2.5 2 1.5 Spiro TMD Module 3.5 0.8 0.06 0 CeO+/Ce+ (%) 0.03 183914
Similar documents
Coding the Clouds: Building Enterprise Apps Using Force.com and Other Cloud Services
More information
ENGLISH COMPREHENSION: Amcat Question Paper by APEX STORY - www.apexstory.com Sample Questions
More information
Wooden Safety Matches Manufacturers and Exporters from apexmatch.com
Apex Match Consortium India Private Limited - http://www.apexmatch.com/wooden-safety-matches.php - is a Manufacturers and exporters of Wooden Stick Matches, Wooden Safety Matches from India.
More information