PDF - Visual Optics Institute
Transcription
PDF - Visual Optics Institute
Ocular Wavefront Error Representation (ANSI Standard) Jim Schwiegerling, PhD Ophthalmology & Vision Sciences Optical Sciences University of Arizona People • Ray Applegate, David Atchison, Arthur Bradley, Charlie Campbell, Larry Horowitz, David Loshin, Scott MacRae, Susana Marcos, Dan Neal, Austin Roorda, Tom Salmon, Jim Schwiegerling, Larry Thibos, Rob Webb, David Williams and others… Reasons for Standardization • Zernike polynomials have traditionally been used to represent wavefronts in optical systems with circular pupils. • First developed by Fritz Zernike in the 1930s for phase contrast microscopy. Multiple ways of scaling, orienting and ordering the basic polynomials have evolved, which can lead to confusion. • The standard helps to remove ambiguity to facilitate clarity and exchange between all users. • Lessons learned from Corneal Topography standards in the 1990s. References • Applegate RA, Thibos LN, et al. Reference Axis Selection: Subcommittee report of the OSA working group to establish standards for measurement and reporting of optical aberrations of the eye. J Refract Surg 16; S656-S658:2000. • Thibos LN, Applegate RA et al. Standards for reporting the optical aberrations of eyes. J Refract Surg 18; S652-S660:2002. • Appendix 1 of both Customized Corneal Ablation: The Quest for Supervision. Ed. MacRae SM, Krueger RR, Applegate RA (Slack, Thorofare, NJ, 2001) and Wavefront Customized Visual Correction: the Quest for Supervision II. Ed. Krueger RR, Applegate RA, MacRae SM (Slack, Thorofare, NJ, 2001). • ANSI Z80.28-2004 Methods for Reporting Optical Aberrations of Eyes. • ISO/DIS 24157 (Draft currently being voted on 2007) Wavefront Error Measurement Coordinate System y Polar Coordinates: r θ x rmax r ranges from [0, rmax] θ ranges from [0°, 360°] Normalized Coordinate System ANSI STANDARD y Normalized Polar Coordinates: ρ θ x 1 ρ ranges from [0, 1] θ ranges from [0°, 360°] Another Coordinate System NON-STANDARD y Normalized Polar Coordinates: φ ρ x 1 ρ ranges from [0, 1] θ ranges from [-180°, 180°] The Third Dimension The z-axis is perpendicular the and x and y-axes and coincides with the Line of Sight. The Line of Sight connects the point of fixation to the center of the entrance pupil, which in turn connects the center of the exit pupil to the fovea. Radial Polynomial, ρ Zernike Polynomials Azimuthal Frequency, θ Complex Wavefront In general, wavefronts can take on a complex shape and we need a way of breaking down this complexity into more simpler components. Zernike Decomposition -0.003 x = Spherical Refractive Error + 0.002 x Cylindrical Refractive Error + 0.001 x Coma Wavefront Error Representation • The wavefront error can be represented by n = 0, 1, 2… ; m = -n, -n +2 … n-2, n Generalized Zernike Polynomials Double Index n is radial order m is azimuthal frequency Radial Component Normalization Azimuthal Component ANSI Standard Zernikes constant that depends on n & m Kronecker delta function e.g. ANSI Standard Zernikes only depends on |m| (i.e. same for both sine & cosine terms Constant that depends on n and m Powers of ρ Factorial Function - a! = a (a-1) (a-2) … (3) (2) (1) e.g. Example Zernike Polynomial Oblique Trefoil Zernike Polynomials - Single Index Radial Polynomial, ρ ANSI STANDARD Starts at 0 Left-to-Right Top-to-Bottom Z0 Z1 Z3 Z11 Z5 Z4 Z7 Z6 Z10 Z2 Z8 Z12 Azimuthal Frequency, θ Z9 Z13 Z14 Other Single Index Schemes NON-STANDARD Z1 Z2 Z3 Z4 Z5 Z7 Z11 Starts at 1 cosines are even terms sines are odd terms Z6 Z8 Z9 Z12 Z13 Z10 Z14 Z15 Noll, RJ. Zernike polynomials and atmospheric turbulence. J Opt Soc Am 66; 207-211 (1976). Also Zemax “Standard Zernike Coefficients” Other Single Index Schemes NON-STANDARD Z1 Z2 Z3 Z4 Z5 Z7 Z9 Starts at 1 increases along diagonal cosine terms first 35 terms plus two extra spherical aberration terms. No Normalization!!! Z6 Z8 Z10 Z12 Z13 Z11 Z17 Z18 Zemax “Zernike Fringe Coefficients” Also, Air Force or University of Arizona Other Single Index Schemes • Born & Wolf NON-STANDARD • Malacara • Others??? Plus mixtures of non-normalized, coordinate systems. Use two indices n, m to unambiguously define polynomials. Use a single standard index if needed to avoid confusion. Examples 4mm Example 1: 4m 0.25 D of myopia for a 4 mm pupil (rmax = 2 mm) Examples Example 2: 2mm 1m 1.00 D of myopia for a 2 mm pupil (rmax = 1 mm) Same Zernike Expansion as Example 1, but different rmax. Always need to give pupil size with Zernike coefficients!! Radial Polynomial, ρ Orders of Zernike Polynomials Low Order Higher Order Azimuthal Frequency, θ Summary • Use the two-index scheme n, m to unambiguously define the Zernike polynomials whenever possible. • If needed, use the standard single index top-to-bottom, left-to-right notation. • Always include the size of the pupil with the Zernike coefficients. • Be aware that other schemes exists in the literature and in other fields of optics.
Similar documents
Pupil matching of Zernike aberrations
Zernike aberrations of low radial order, with a high optical quality [8]. For both measurement systems, a reference wavefront is measured by simply removing the plate. The plates have some marks th...
More information