Definitions n Flow Cytometry u n Measuring properties of cells in flow Flow Sorting u u Sorting (separating) cells based on properties measured in flow Also called Fluorescence-Activated Cell Sorting (FACS) Basics of Flow Cytometry •Cells in suspension Fluidics •flow in single-file through •an illuminated volume where they Optics •scatter light and emit fluorescence •that is collected, filtered and Electronics •converted to digital values •that are stored on a computer Flow Cell Injector Tip Sheath fluid Fluorescence signals Focused laser beam Purdue University Cytometry Laboratories Forward Angle Light Scatter Laser FALS Sensor Purdue University Cytometry Laboratories 90 Degree Light Scatter Laser FALS Sensor 90LS Sensor Optics - Fluorescence Channels n n The fluorescence emitted by each fluorochrome is usually detected in a unique fluorescence channel The specificity of detection is controlled by the wavelength selectivity of optical filters and mirrors Fluorescence Detectors Laser Freq FALS Sensor Fluorescence Fluorescence detector (PMT3, PMT4 etc.) Common Laser Lines 350 300 nm 457 488 514 400 nm 500 nm 610 632 600 nm 700 nm PE-TR Conj. Texas Red PI Ethidium PE FITC cis-Parinaric acid Example Channel Layout for PMT Laser-based Flow Cytometry 4 Flow cell PMT Dichroic Filters 3 PMT 2 Bandpass Filters PMT 1 Laser Fluorescence Activated Cell Sorting 488 nm laser FALS Sensor Fluorescence detector Charged Plates Single cells sorted into test tubes - + Emocromo, determinazione con tecniche manuali e automatizzate Blood Components: Cells Blood Components: "Blood Count" – % of Each Component Figure 16-2: The blood count Manual Hematocrit • “PCV”, “HCT”, manual HCT, "spun crit“ • Centrifugation, chart reading as % Manual hematocrit • Advantages: - “Gold standard” in animals? - Examine plasma for color changes - Plasma for protein/fibrinogen assays • Errors: - Falsely increased: trapped plasma between RBCs - Falsely decreased: shrinkage induced by excess EDTA - Transcription to report Calculated Hematocrit • Calculated hematocrit = MCV x RBC count / 10 • No plasma trapping, no RBC shrinkage • Accurate if cell counter validated for veterinary species (modified human instruments) Hemoglobin • Colorimetric assay following lysis of erythrocytes • Falsely increased by interference with Hb assay: plasma change? cell debris? - Lipemia - Marked leukocytosis ( > 50,000/µL) EMOCROMO Erictrociti: (RBC) -Diluizione 1/100 con fisiologica - si contano RBC in 10 rettangoli di 1/1000 mm3 - il risultato x 10.000 = RBCx106/mm3 Leucociti (WBC) - diluizione 1/10 con soluzione di lisi (liquido di Türk: ac. acetico 4% + violetto di genziana 1% - si contano WBC in 1 quadrato di 1/10 mm3 - il risultato x 100 = WBCx103/mm3 Piastrine (PLT) - Diluizione 1/20 con soluz. di lisi - si contano PLT in 20 rettangoli di 1/1000 mm3 - il risultato x 1000 = PLTx103/mm3 VCS Technology