Wireless Temperature Monitoring Infrastructure

Transcription

Wireless Temperature Monitoring Infrastructure
Wireless Temperature Monitoring Infrastructure
Cold chain management—the process of monitoring temperature-sensitive products moving from
one partner or location to another—is a complex endeavor with many variables that can adversely affect
quality, freshness and safety. When a load is exposed to various methods of transportation, multiple
handoffs between receivers, and time spent in staging and/or storage, quality can be compromised
through excursions in time and temperature. Electronic monitoring technology gives receivers
a snapshot of a delivery’s cold chain history, but requires labor to retrieve, download and interpret the data.
Wireless temperature monitoring automates the data collection and download process, delivering accurate
and comprehensive data for every trip.
Sensitech has taken the mystery out of wireless technology. The ColdStream® RF Infrastructure operates in
a mesh-networking environment. The Infrastructure integrates the data collection and communication
technologies necessary to automate the process of collecting and managing comprehensive time, temperature
and location information in a reliable and cost-effective manner.
Benefits of Wireless Technology
• Wireless downloads automate data collection
and communication for increased operational
efficiencies—no monitor retrieval or data
conditioning required.
• Comprehensive time, temperature and location
information deliver a broader picture of the
cold chain process.
www.sensitech.com
• Secure, validated, centralized data
management allows information to
be shared among partners.
• Automated alarming and alerting improves
quality, reduces waste and enables receivers
to prioritize and focus resources appropriately.
• Tailored robust reporting facilitates sound
decision making.
Infrastructure Components
HARDWARE
TTRF Specifications
TempTale® RF (TTRF) temperature monitors are part of
Sensitech’s family of precision devices designed to track and
collect time and temperature data about temperature-sensitive
shipments. These highly reliable, wireless monitors collect and
store temperatures for a wide array of in-transit and storage
applications. TTRF is designed with configurable time and
temperature limits to trigger time-out-of-range alerts, along
with an easy-to-read LCD screen for immediate shipment
evaluation. Use our monitors to:
Monitor specification
Single use, ambient
Read Range
up to 100 meters (328 feet) line of sight
Frequency Bands
915 or 868 MHz
Temperature
Measurement Range
-22ºF to +158ºF
(-30ºC to +70ºC)
• Start or stop data collection using the front
panel buttons
Battery Life
up to one year
Temperature Accuracy
±2ºF from -22ºF to 0ºF
(±1.1ºC from -30ºC to -18ºC)
±1ºF from 0ºF to +122ºF
(±0.55ºC from -18ºC to +50ºC)
±2ºF from +122ºF to +158ºF
(±1.1ºC from +50ºC to +70ºC)
• Store and record location information when other
ColdStream RF Infrastructure components are detected
Memory Capacity
1,920 data points (2K)
Programmable
Temperature Alarms
Single and cumulative
time-out-of-range events
Display Current
Temperature Readings
LCD factory-programmable option
Start-Up Delay
Configurable
Water Resistant
Housing
NEMA 4; IP64 rated
Start & Stop Buttons
Color-coded, finger buttons for
easy execution
Dimensions
4.25” L x 2.25” W x 0.86” H
(10.80 cm x 5.72 cm x 2.18 cm)
Weight
3.1 ounces (88 grams)
Programmable
Measurement Interval
Selectable
Primary Sensor
Resolution
0.1º (1/10º) over full operational
temperature range
www.sensitech.com
• Measure and store ambient temperature data at
set intervals
• Set alarm limits
• Read information via LCD display
• Operate within the 915 MHz or 868 MHz ISM band
for efficient transmission in high water content
product situations
• Leverage reader-talk-first mode—monitors will never
transmit until they are in the vicinity of an active
ColdStream Infrastructure component (i.e., an operational
TTRF Gateway and/or TTRF Repeater); this mode is
required for air transit
TempTale RF Gateway is an AC powered reader that is
attached to the network via an Ethernet connection. The
TTRF Gateway wirelessly communicates with TTRF monitors
directly or through TTRF Repeaters. When a TTRF Gateway
is shipped, its operating frequency band is set by country.
The TTRF Gateway automatically chooses a channel within the
band based on the current signal-to-noise ratio measured in
each channel. The TTRF Gateway contains a firmware-based
Ethernet controller that is assigned an IP address.
TempTale RF Repeater is an AC powered unit used to extend
the area that is covered by the network. TTRF Repeaters pass
signals between the TTRF monitors, other TTRF Repeaters and
the TTRF Gateway. When a TTRF Repeater is first installed, it
searches for the presence of a TTRF Gateway and establishes
communication on the same channel as the TTRF Gateway.
TempTale RF Signpost is used at locations where it is
not necessary to read data from the TTRF monitors. TTRF
Signposts transmit a location ID and are typically used to mark
the monitor’s arrival and departure times at particular locations.
SOFTWARE
Remote Site Server (RSS) is a Windows®-based software
agent that manages the activity of the hardware components
to ensure that new TTRF monitors are read and downloaded
when they are detected in the network. RSS forwards the
downloaded data files via high-speed Internet connection to
Sensitech’s secure central data repository—ColdStream.
RSS Requirements
Operating Systems
• Windows® 7 Enterprise
• Windows® XP Professional
• Windows® 2003 Server
ColdStream is a validated, hosted and secure relational
database application easily accessible via the Internet for query,
reporting and analysis of stored data. ColdStream enables
receivers to share critical data efficiently through password
protected, selective access—across their own organization or
with selected trading partners.
Internet Connection
• High Speed Required
Languages
• U.S. – English
Framework
• MS .NET Framework 3.5
Communication
to ColdStream
• http, https via ports 80 and 443
Communication
to TTRF Gateway
• TCP/IP via ports 4900-4904
How the ColdStream Wireless Infrastructure Works
Every receiving site is unique. For optimal performance, our
experienced technical field teams conduct site surveys, which
include receiving site layouts and sophisticated transmission
testing to ensure high-quality read rates.
Outfitting small areas would likely consist of one TTRF
Gateway. Larger areas, such as a distribution center with
dozens of dock doors, would also include several TTRF
Repeaters. For any location that is not transmitting data,
a TTRF Signpost would be used to merely mark the monitor
data with its location identifier.
When a TTRF monitor detects the presence of a TTRF
Gateway, TTRF Repeater, or stand alone TTRF Signpost,
the monitor records the facility’s location identifier associated
with that network, thereby providing time, temperature and
location information.
ColdStream
SECURITY
Your System Is Secure
Data is Safe from Tampering
• Data is in binary format
• Data is encrypted via TEA (Tiny Encryption Algorithm)
Infrastructure is Safe from Tampering
• ColdStream RF Infrastructure only accepts valid
data packets
• TTRF monitors only communicate when asked, and
only respond to a set list of ColdStream commands
Infrastructure Protects Your Systems from Interference
• Communicates only with other ColdStream components
• Can co-exist on wireless networks without interfering
• Has very low bandwidth requirements and will not
overload your networks
Data within the ColdStream RF Infrastructure is safe from
tampering. Monitor data is encrypted at the source with
a TEA (Tiny Encryption Algorithm) and decrypted at the
destination (on the TTRF Gateway). This algorithm provides
basic protection from inadvertent viewing or hacking.
In addition, the data downloaded from a TTRF monitor is in
binary format which is not human readable. This provides an
additional level of security from unauthorized data access.
Security has been integrated into the infrastructure level.
ColdStream RF Infrastructure is designed to accept only valid
packets with a known destination. In addition, TTRF monitors
will only communicate with the ColdStream RF Infrastructure
when asked and will only respond to a set list of commands.
The ColdStream RF Infrastructure is designed to not interfere
with any of your existing systems. It cannot communicate with
any devices other than ColdStream devices. The bandwidth
requirement is very low and will not overload your networks.
ColdStream RF Infrastructure is installed to ensure that it can
co-exist with your wireless networks without causing any
interference issues.
As the world’s leading provider of cold chain visibility solutions, Sensitech Inc. enables global leaders in the food, pharmaceutical, and industrial markets to track and monitor assets across the supply chain in
order to protect the integrity of temperature-sensitive products. Sensitech is an ISO 9001:2008 company based in Beverly, Mass., with offices in Amsterdam, Calgary, Melbourne, Mumbai, Redmond, Santiago,
and Shanghai, and additional service and distribution locations around the world. Sensitech is a wholly owned subsidiary of Farmington, Conn.-based Carrier Corp., the world’s leader in high technology heating,
air-conditioning and refrigeration solutions with operations in 172 countries. Carrier Corp. is a unit of United Technologies Corp. (NYSE:UTX), a Hartford, Conn.-based provider of a broad range of high technology
products and support services to the aerospace and building systems industries worldwide. For additional information, please call +1-978-927-7033 or visit www.sensitech.com. © 2011. Sensitech Inc.
All Rights Reserved. Unless otherwise indicated, all trademarks and service marks are the property of Sensitech Inc. Windows is a registered trademark of Microsoft Corporation in the United States and
other countries.
A Carrier Corp. Subsidiary
Amsterdam
Boston
Calgary
Melbourne
1/11 1500
Mumbai
Redmond
Santiago
Shanghai
Sensitech Inc. • 800 Cummings Center • Suite 258X • Beverly, MA 01915-6197 • 1-800-843-8367 • +1-978-927-7033 • Fax: +1-978-921-2112 • www.sensitech.com