Instructions to adjust
Denester set 6100100421
Ovologic/Twinpack Tray
for PSPC
01-07--2015 EtP
The Ovologic tray is slightly different from the Twinpack tray. Picture below shows the
side were the PSPC topgrippers separate the trays. The opening of Ovologic trays is more
to the centre than the Twinpack tray. With the standard denester set this is causing
problems (double trays or no tray is coming out of the denester) We added a new part to
the existing denester set and this manual shows how to install and adjust.
01-07--2015 EtP
1) Remove the safety covers from the denester.(2x)
2) Remove the existing top grippers (4x)
01-07--2015 EtP
3) Bolt the 4 topgrippers to the adapter plate with the original bolts and nuts. The white
nylon spacer rings are not needed anymore.
4) Use the added bolts and nuts to mount the adapter plate in the denester.
4x 3000305043 adapter plate Ovologic PSPC
8x 5000200314 Bolt M6x20
8x 5000300034 ring M6
8x 5000100010 lock nut M6
01-07--2015 EtP
5) Be sure that the outside pins are grainded off (A) and that the space between the top
grippers and the vertical shaft is 2 mm (B)
01-07--2015 EtP
6) Top gripper plate must be adjusted maximum out.
01-07--2015 EtP
7) Rough height adjustment of topgrippers is 85 mm.
(in normal stop position)
8) Rough height adjustment of down grippers is 4 mm.
01-07--2015 EtP
9) Rough adjustment of the down gripper in normal (maximum down) stop position
from plastic block to the tip of gripper is 28 mm.
10) Fine tune or re-adjust the denester when needed, by using the manual tip switch on
the conveyor.
01-07--2015 EtP
11) Lubricate all moving parts of the denester weekly, follow the lubrication instructions in
the user manual. (chapter 5 – Preventive Maintenance)
12) Put the safety covers (2x) back on the denester.
13) In case of any questions, contact your local dealer.