Ozone Products
Transcription
Ozone Products
PCI-WEDECO Environmental technologies Ozone Products Municipal and Industrial Ozone System PDO/PDA Systems Type PDO/PDA High Capacity Ozone Generators Ozone System PDO/PDA Ozone generators for large-scale oxidation applications PCI-WEDECO PDO/PDA ozone generators are the overwhelming choice of design engineers and end-users worldwide who require dependable, efficient production of large quantities of ozone to meet their process needs. This is because PDO/PDA series generators have been engineered from the ground up with customer requirements in mind. The result is the most compact, cost-effective and reliable ozone generation system available. ozone generator with unmatched reliability, production flexibility and efficiency, all in a compact package that minimizes space requirements and associated facility construction costs. PDO/PDA ozone generators are also unique in that they are the only large-scale ozone generators available that are factory pre-assembled and fully performance tested prior to delivery. This provides our customers with the peace of mind that their ozone plant will start up on time and perform according to design, every time! For individual unit ozone capacities beginning at 400 pounds per day (ca. 7500 grams/hour) and continuing to more than 6000 PPD (113 kg/hr), there is a standard PDO/ PDA model to meet your needs. In addition, custom generators can be manufactured to produce larger quantities of ozone if required. Whether the challenge involves drinking water treatment, chemical oxidation, bleaching or pollution control, PDO/PDA series generators can provide the solution. PDO/PDA Ozone Generators: Unique design. Unique performance. Two key features separate PDO/PDA generators from all others. These include PCI-WEDECO’s exclusive use of TM patented Effizon HP electrode/dielectric technology and proprietary high performance variable frequency power supply technology. These features combine to produce an 18 16 WEDECO EFFIZON HP-Ozone generator Ozone concentration [wt%] 14 12 WEDECO Standard Ozone generator 10 8 Traditional Ozone generator 6 4 60 80 100 120 140 160 180 Rel.energy consumption [%] at constant oxygen throughput 200 PDO-7000 Ozone Generator Assembly Ozone System PDO/PDA TM Effizon HP dielectric technology – The heart of the ozone generator The environment inside an ozone generator is an unforgiving one both chemically and electrically. High electrical voltages combined with aggressive oxidant gases require that an ozone generator be designed using suitable materials of construction as well as high breakdown safety factors to ensure long-term, reliable performance in the TM field. PCI-WEDECO’s patented Effizon HP electrode/ dielectric assembly accomplishes this like no other system. While some systems utilize unreliable enamels or similar TM dielectric materials, all Effizon HP component materials are impervious to the harsh chemical environment in the TM generator. And Effizon HP dielectrics have a 10:1 electrical breakdown factor of safety, versus typical values of less than 2.0:1 for other generator manufacturers. The result is clear: PDO/PDA generators have eliminated the problem of dielectric failures, as well as the down time and maintenance costs associated with them. GUARANTEED! TM Effizon HP Dielectric Assembly Glass Dielectric Tube (open both ends) ↑ Stainless Steel Ground Electrode ↑ Effizon Mesh Oxygen/Air Stainless Steel HV-Electrode PDO/PDA self-contained power supply, mounted on fully assembled skid for easy installation. PCI-WEDECO is the only major ozone system supplier to use high performance variable frequency electronic power supplies in all large-scale ozone generators. PDO-16000 Ozone Generator Variable Frequency Power Supply Units – Maximum control flexibility and efficiency The performance of any ozone generator is dependant not only on the dielectric assembly, but also on optimum power delivery to the ozone generator cells. PCI-WEDECO’s proprietary variable frequency power supply units (PSU) deliver power smoothly, reliably and flexibly for maximum performance and efficiency. By using frequency to adjust the ozone concentration and output, PDO/PDA series PSU’s exhibit precise, linear ozone output control as well as a very wide turndown range (up to 100:1). In contrast to variable voltage PSU designs, the voltage is held constant throughout the range. As a result, the ozone output turndown remains linear all the way to the bottom. In addition, our variable frequency PSU’s maintain a very high power factor (>0.98) throughout their operating range. This eliminates the significant efficiency losses on turndown associated with power factor erosion, that is common on variable voltage PSU designs. PDO/PDA variable frequency PSU’s include the following major components: • • • • • AC to DC Input Converter Variable, Medium Frequency DC to AC Inverter High Voltage Transformer Closed to Open Loop Inverter Recooling Unit Integrated PLC control system Each PSU major component section is located within a segregated PSU cabinet compartment with separate access doors for maximum electrical safety and maintenance convenience. Ozone System PDO/PDA In addition, our exclusive use of the closed to open loop Inverter Recooling Unit ensures that the PSU power electronics will last and eliminates the risks associated with direct water cooled PSU configurations. Designed specifically to operate together, PCI-WEDECO’s TM Effizon HP dielectric assembly and variable frequency PSU represent the perfect pair for high concentration, high capacity ozone production! PDO/PDA Series Advantages: • • • • • • • • • • • TM Effizon HP dielectric technology for unmatched reliability! Guaranteed! Variable frequency PSU for maximum efficiency, turndown and control High ozone concentration (to 16% by weight) capability reduces oxygen costs Very low specific energy consumption Safe, logical PSU design with segregated electrical compartments and specially designed inverter recooling unit Sophisticated PLC control High quality construction by experienced staff at our USA and Germany facilities Attractive, compact design reduces plant construction costs Factory pre-assembly and skid mounting significantly lowers field assembly, installation time and cost Full production performance testing of every unit in our factory prior to shipment! No one else offers this benefit! Eliminates any uncertainty of ozone system performance during plant start-up! Insist upon it! PCI-WEDECO Factory Factory Assembly and Performance Testing All PDO/PDA series ozone generators are factory preassembled and fully performance tested prior to delivery. This is possible in part because of PCI-WEDECO’s fully integrated engineering, manufacturing and test facility in West Caldwell, New Jersey, USA, as well as our unique TM technology. Effizon HP dielectrics configuration enable them to be installed, tested and shipped within our generators directly to the project site, eliminating the need to deliver them separately in special packaging and install them on site. Following assembly in our factory, each ozone generator is rigorously tested to full output, through its design operating range and for conformance with any specific project requirements or guarantees. Often, customers join this testing to gain confidence with the unit and receive preliminary training on its operation. Advantages: • • PDO 8000 Ozone Generator Experienced factory assemblers prevent mistakes that can occur using contract labor on site that most likely has never seen an ozone system. Factory pre-assembly is faster, and minimizes site installation time due to the simple connection requirements. This can result in significant project cost savings due to the shortened project schedule and reduced labor costs. Ozone System PDO/PDA PDO/PDA Models and Capacities Ozone Production - PPD (Pounds Per Day) Air Feed Model PDO/PDA 1000 PDO/PDA 2000 PDO/PDA 3000 PDO/PDA 4000 PDO/PDA 5000 PDO/PDA 6000 PDO/PDA 7000 PDO/PDA 8000 PDO/PDA 9000 PDO/PDA 10000 PDO/PDA 11000 PDO/PDA 12000 PDO/PDA 13000 PDO/PDA 14000 PDO/PDA 15000 PDO/PDA 16000 PDO/PDA 17000 2.7% wt. 132 216 279 340 420 513 650 777 882 1075 1200 1375 1600 1950 2275 2550 3000 Oxygen Feed 6% wt. 371 606 782 952 1176 1437 1815 2177 2471 3010 3353 3850 4480 5460 6370 7140 8330 8% wt. 10% wt. 12% wt. 318 519 670 816 1008 1232 1556 1866 2118 2580 2874 3300 3840 4680 5460 6120 7140 265 433 559 680 840 1027 1300 1555 1765 2150 2400 2750 3200 3900 4550 5100 6000 212 346 447 544 672 821 1037 1244 1412 1720 1916 2200 2560 3120 3640 4080 4760 *ppd=pounds per day 3 Calculated Ozone Gas Flow scfm (Nm /h) Ozone Gas Flow - SCFM Air Feed Model PDO/PDA 1000 PDO/PDA 2000 PDO/PDA 3000 PDO/PDA 4000 PDO/PDA 5000 PDO/PDA 6000 PDO/PDA 7000 PDO/PDA 8000 PDO/PDA 9000 PDO/PDA 10000 PDO/PDA 11000 PDO/PDA 12000 PDO/PDA 13000 PDO/PDA 14000 PDO/PDA 15000 PDO/PDA 16000 PDO/PDA 17000 Oxygen Feed 2.7% wt. 6% wt. 8% wt. 40.7 66.5 85.9 104.5 129.1 157.8 199.8 239.0 271.2 330.4 368.8 422.6 491.8 599.4 699.3 783.8 922.2 50.5 82.6 106.6 129.7 160.2 195.9 247.4 296.6 336.6 410.1 456.8 524.5 610.4 743.9 867.9 972.8 1135.0 32.5 53.1 68.5 83.3 103.0 125.9 159.0 190.6 216.4 263.6 293.7 337.2 392.4 478.2 557.9 625.4 729.6 10% wt. 21.6 35.4 45.7 55.5 68.6 83.9 106.2 127.1 144.3 175.7 196.2 224.8 261.6 318.8 371.9 416.9 490.5 12% wt. 14.4 23.6 30.4 37.0 45.7 55.9 70.6 84.7 96.2 117.1 130.5 149.8 174.4 212.5 247.9 277.9 324.2 Ozone System PDO/PDA High Capacity Ozone Applications n Drinking Water Treatment ♦ ♦ n Chemical Oxidation and Synthesis ♦ ♦ n Organic synthesis (ozonolysis) Coating surface preparation Pollution Control ♦ ♦ ♦ n Preoxidation of organic or inorganic constituents Disinfection COD reduction and cracking for improved biodegradation Color and odor elimination NOx reduction in offgas streams Bleaching ♦ ♦ The PCI-WEDECO facility in New Jersey, USA Paper pulp Kaolin clay Other PCI-WEDECO Products and Services n Ozone Measurement and Safety Monitors ♦ ♦ ♦ n n ♦ ♦ ♦ ♦ ♦ ♦ n Catalytic destruct units Coating surface preparation Custom thermal destruct units ♦ n Liquid oxygen (LOX) tanks and evaporators PSA oxygen generators VSA oxygen generators Air preparation and nitrogen boost systems Comprehensive Control Solutions ♦ Venturi injectors Injection/degassing systems Diffusion systems Residual Ozone Destruct Units Feed Gas Supply Systems ♦ High Concentration ozone production monitors Ozone offgas residual monitors Ambient ozone leak detection monitors Ozone Contacting and Reaction Systems ♦ ♦ ♦ n Ozone system master controls Plant-wide SCADA systems Laboratory Testing and Pilot Plant Services ♦ ♦ Treatability testing and analysis On-site pilot plant testing PCI-WEDECO Environmental Technologies Inc. 1 Fairfield Crescent, West Caldwell, NJ USA 07006 * Tel. 973-575-7052 * Fax. 973-575-8941 www.pci-wedeco.com * munsales@pci-wedeco.com