Preliminary Evaluation of C1 Implants

Transcription

Preliminary Evaluation of C1 Implants
30
News No. 30 October 2012
Preliminary Evaluation
of C1 Implants
®
MAKE
IT
SIMPLE
2
News 30, News 30, October 2012
Preliminary Evaluation of C1 Implants
Jorge Arango; 2 Leonardo Calvache; 2 Miguel Ferrigno
1
Introduction
The Center of Oral Implantology at the
Colombian School of Dentistr y has
evaluated a new implant system made by
MIS Technologies LTD.
The C1 Implants are conical, self-tapping
implants with three parallel micro rings at
the coronal area. The surface treatment is a
combination of sandblasting and acid etching. Its
conical connection features platform switching
as well as an internal anti-rotation mechanism.
The implants are color-coded based on their
restorative platform.
We selected five patients who needed one
to four implants as part of their restorative
treatment plan. In four cases implants were
placed in the mandible. In these cases, the
bone was classified as type I and type II
bone. The fifth case required placement of
an implant at anterior maxilla. Bone type was
classified as type III.
Altogether, our surgeons: Dr. Calvache and
Dr. Ferrigno used twelve implants. Eight
were 3.75 diameter implants; four 10mm
long and four 11.5mm long, and four were
4.2 diameter impalnts; one 10 mm long and
three 11.5mm long. None of the implants were
immediately loaded.
The following parameters were evaluated
during the surgical phase: drilling sequence,
delivery to site, insertion, stability, cover screw or
healing cap handling and an overall evaluation.
Conclusions
Based on this preliminary evaluation of twelve
C1 implants, our surgeons concluded the
following:
▪ The surgical kit's arrangement is logical,
ergonomic, and non-complex. Following the
correct sequence was easy.
▪ The double packing system ensures
sterilization and safety of the implants.
▪ The conical root-shaped body of the implants ,
their thread design and the self-tapping property,
as well as their ability to mildly compress bone,
enhance implants' primary stability.
▪ The micro rings on implant’s neck and the
dual thread design improve bone to implant
contact at the cervical zone.
▪ The conical connection offers better seal
and minimizes micro-movements, ensuring
preservation of bone.
▪ The color coding of the platforms, visible
both within the internal connection and on the
various components really is a great advantage.
▪ The full range of pilot drills, each with a builtin stopper, helps to determine the correct
length, enhance safety and overall facilitates
the surgical procedure.
▪ The final drills, which are packed with each
implant, easily cuts through bone.
▪ The direction indicator tools facilitates the
identification of the three dimensional position
of the implants and its connection.
▪ The insertion system is very convenient and
minimizes the overall number of tools.
This initial evaluation presents positive results.
However, it is necessary to develop research
studies that will be able to present supportive
conclusions, based upon scientific evidencebased data.
Patient Report
Case
1
Name
C.G
Age
46
2
J.L
25
3
O.C
78
4
O.S
36
5
L.P
47
Implants
Implants
Diameter(mm)
Length (mm)
46
4.2
11.5
47
4.2
11.5
34
41
46
47
34
3.75
3.75
3.75
3.75
3.75
10
10
10
10
11.5
44
4.2
10
45
4.2
10
47
3.75
11.5
22
3.75
11.5
12
3.75
11.5
UNICOC (Institucion universitaria colegio
odontologo Colombiano) is a leading institute
for Odontological studies in Colombia.
It was established by Prof. Jorge Rene Arango
Tamayo and received its recognition as an
academic institute by the national ministry of
education in 1975. It acts as an active member of
the Colombian Association of dentistry faculties
(ACFO) since 1981, and as a founding member
of the Colombian association of private university
institutions (ACIUP) since 1988.
UNICOC 's vision is to become a world leader
through extensive research activities, through
broad scientific educational and training
programs, through innovation, and through
social responsibility.
1
Prosthodontist, Postgraduate Professor, Oral Implantology Center Colegio Odontologico, Institución Universitaria Colegios de Colombia UNICOC.
2
Oral and maxillofacial surgeon, Postgraduate Professor, Oral Implantology Center Colegio Odontologico, Institución Universitaria Colegios de Colombia UNICOC.
3
News 30, October 2012
CT Scan and X Rays
Pre Surgical
Post Surgical
Case 1
Fig. 2
Case 2
Case 3
Case 4
Case 5
MIS’s Quality System complies with international quality
control standards: ISO 13485:2003 - Quality Management
System for Medical Devices, ISO 9001: 2008 – Quality
Management System and CE Directive for Medical Devices
93/42/EEC. MIS’s products are cleared for marketing in the
USA and CE approved.
© MIS Corporation. All rights Reserved
MC-N3012 Rev.2
www.mis-implants.com
®
MIS Implants Technologies Ltd.
www.mis-implants.com

Similar documents

Preliminary Evaluation of C1 Implants

Preliminary Evaluation of C1 Implants contact at the crestal zone. This initial evaluation presents positive results. However, it is necessary to develop research studies to come to stronger conclusions based upon scientific evidence.

More information