ACONCEPT

Transcription

ACONCEPT
PERFORMANCE, FREEDOM, SIMPLICITY
A
CONCEPT
G C B
The new dimension
2
anthogyr
A: 1 GLOBAL CONCEPT, 1 TRULY COMPR
An ergonomically designed and exhaustive range that offers the best solution for
D
E
F
* ISO 5832-2 standard « Implants for surgery – Metallic materials» - part 2, ISO 5832-3 standard «Implants for surgery –
Metallic materials» - part 3
** As per recommended protocol
*** Data on file at Anthogyr
3
ACONCEPT,THE
N E W
D I M E N S I O N
EHENSIVE RANGE, 3 COMPLEMENTARY OPTIONS
EVERY clinical indication
CONICAL, STRONG AND TIGHT SEAL
CONNECTION
w
w
w
w
w
Morse tapered connection.
Even distribution of mechanical stresses.
No micromotions: no bacterial infiltration.
Preservation of alveolar bone.
Subcrestal positioning for an aesthetic result.
« PLATFORM-SWITCHING »
w Preservation of cortical bone.
w Optimized biomechanical behavior.
w BCP®-treated neck and platform for enhanced
osteoconduction.
w Higher mechanical strength than Grade IV titanium,
and reduced risk of breakage (860 MPa vs 550 MPa)*.
w Less invasive: smaller diameter implant used in the
same site.**
w Proven biocompatibility.
EFFECTIVE STIMULATION OF BONE
w Optimized use of the threaded surface area.
w Minimal stress concentration at tip threads.
w Optimal conversion of occlusal loads into compressive
forces which stimulate bone formation.
E
w Optimized bone anchorage.
GRADE V TITANIUM
(FDA APPROVED, ASTM B34808)
w Preservation of the biological space.
w Gingival management, mucous
«O-Ring».
w Epithelial preservation.
w Preservation of alveolar crest
bone height.
F
SANDBLASTED THREADED NECK
BCP® (BIPHASIC CALCIUM PHOSPHATE)
OSTEOCONDUCTIVE SURFACE
BCP® grit-blasted surfaces
w High biocompatibility: fast and effective osseointegration without
any contamination of the adjacent tissue.
w Optimal surface roughness: enhancement of cell attachment
promotes implant stability and ensures rapid osseointegration.
w Successful osseointegration is achieved in more than 99% of
the cases***: superior cell adhesion and proliferation abilities.
SEM observations
of Anthogyr BCP®
implant surfaces
D
x 1000
4
anthogyr
G E, ONE CONCEPT FOR EVEN
COMMON RANGE OF DENTAL RESTORATIONS FOR
BOTH AXIOM® REG AND PX IMPLANTS
NEW
!*
DESIGN
WIDE CHOICE OF EMERGENCE PROFILES
0.75
mm
1.5
mm
2.5
mm
3.5
mm
4.5
mm
Ø 3.4 mm
5 hauteurs gingivales
Ø 4.0 mm
Ø 5.0 mm
Ø 6.0 mm
4 diamètres d’émergence
CONSTANT EMERGENCE PROFILE
Constant emergence profile from healing screw to final abutment:
w No undue tension on soft tissue.
WIDE SELECTION OF PROSTHETIC SOLUTIONS
w Cement-retained, screw-retained, single-unit and multiple-unit
restorations, and full-arch restorations.
w Stabilization of complete denture.
STERILE components for immediate, permanent placement:
w Preservation of periodontal attachment.
w Preservation of biological width.
w Minimal disturbance of soft tissue.
* Availability to be confirmed
5
ACONCEPT,THE
N E W
D I M E N S I O N
MORE FREEDOM!
SINGLE SURGICAL KIT FOR
AXIOM® REG AND PX IMPLANTS
COMMON CONNECTION FOR
AXIOM® REG AND PX IMPLANTS
w Common instrumentation: simple and user-friendly.
Intuitive conical connection thanks to a tri-lobe
indexation:
w Accurate, controlled abutment placement.
w Strong, stable connection even at high torque values.
w Simple drilling protocol: specific to each
Axiom® REG and Axiom® PX implant.
w High intraoperative flexibility: the implant is chosen
according to the clinical situation.
Common connection for all implant diameters:
w Whatever the prosthetic component chosen.
w The prosthetic diameter is chosen independently from
the implant diameter.
w Less restrictions, more flexibility!
w Compact, ergonomic kit.
COMMON
CONNECTION
A
E
simeda
®
customized
&
solutions
YOUR CAD-CAM SOLUTION!
> Implant-supported restorations:
• Cement-retained, screw-retained, single-unit and multiple-unit restorations, and full-arch restorations.
• Free downloadable implant library for all popular implant systems.
> Tooth-supported restorations.
> A large selection of materials to fit all types of restoration: Titanium, Cobalt chromium, IPS e.max® CAD*,
Zirconia, PMMA and PEEK.
*IPS e.max® CAD is a registered trademark of Ivoclar Vivadent.
6
anthogyr
G,
SIMPLY PERFORMING!
Designed for most clinical indications and most
practitioners, whether beginners or experts.
CONICAL CONNECTION
w Sealed morse connection with a 6° half angle.
STRAIGHT THREADED NECK
w Optimized anchorage.
w Retentive neck with bone compaction effect.
CYLINDRICAL-CONICAL SHAPE
w Implant with controlled and guided insertion.
w Simple and intuitive drilling protocol.
PROGRESSIVE ASYMMETRICAL
THREADING
w Self-tapping.
w Gradual bone compaction is achieved during threading.
w Excellent initial stability.
ATRAUMATIC APEX
w Well suited for sinus lift procedures.
w Apical thread design fits any type of bone.
7
ACONCEPT,THE
N E W
D I M E N S I O N
IMPLANTS AVAILABLE FOR EVERY SITUATION
Short implants (6.5 mm or 8.0 mm):
w For placement in anterior and posterior regions
with limited bone height.
Long implants (16 mm or 18 mm) for 3.4 and 4.0 mm
diameters:
w Prostheses are fixed onto a small number and
angled implants placed in the posterior region to
obtain optimal anchorage.
Ø 3.4 mm
Ø 4.0 mm
(1)
(1)
8 mm
10 mm
12 mm
14 mm
16 mm
18 mm
Ø 4.6 mm
(1)
6.5 mm
8 mm
10 mm
12 mm
14 mm
16 mm
18 mm
6.5 mm
8 mm
10 mm
12 mm
14 mm
Ø 5.2 mm
(1)
6.5 mm
6.5 mm 8 mm
8 mm10 mm
10 mm12 mm
12 mm14 mm
14 mm
(1) ID color codes repeated on instruments and labels.
A SIMPLE DRILLING PROTOCOL
Ø 4.0 x 10 mm
w Any type of bone.
w Simple, logical drilling sequence: same color code
for implant and drill.
w Step drills for centered drilling.
w Tapping is recommended in D1 bone type.
w Depth gauges available: 1 per drill diameter.
w Easy to grip, no need for an implant holder: less handling!
w Reference markings: for proper orientation of the tri-lobe
feature and vertical positioning of the implant.
w Subcrestal positioning of the implant for an aesthetic result.
Ø 2.0
Drill
GUIDED SURGERY
TION
INNOVA
Ø 3.0
Drill
Ø 3.6
Drill
Ø 4.0
Tap
(optional)
ANTHOGYR Guiding System
> Compatible with Axiom® REG*.
> Simplant PRO® software: a universal planning system
with a user-friendly interface.
> Compact surgical kit: includes a unique, small-size
centering sleeve.
*For 3.4 mm, 4.0 mm and 4.6 mm diameters.
8
anthogyr
C, PROMISE OF EXPERTISE
In cases of immediate postextraction implant placement, and
insertion in low-density bone. Reserved for experienced
practitioners. Optimal primary anchorage!
CONICAL CONNECTION
w Sealed morse connection with a 6° half angle.
REVERSE CONICAL NECK
w Preservation of cortical bone.
w Promotes alveolar bone remodeling.
CONICAL SHAPE
w Gradual bone condensing effect.
w Enhanced initial stability in low-density bone.
w Protocol designed for sub-drilling procedure.
DEEP, SHARP THREADS
w Self-drilling, self-tapping.
SYMMETRICAL DOUBLE-THREADS
w Threads with controlled and guided insertion in
low-density bone.
w Easy insertion.
FAST PENETRATION APEX
w Quick insertion into the bone.
w Optimal anchorage on the apical portion.
9
ACONCEPT,THE
N E W
D I M E N S I O N
IMPLANTS AVAILABLE FOR EVERY SITUATION
Short implants (6.5 mm) for 4.6 and 5.2 mm diameters:
Ø 3.4 mm
w For placement in posterior regions with limited bone
height and wide alveolars.
Ø 4.0 mm
(1)
8 mm
10 mm
12 mm
14 mm
16 mm
18 mm
Implant lengths up to 18 mm for 3.4 and 4.0 mm
diameters:
w Prostheses are fixed onto a small number and angled
implants placed in the posterior region to obtain optimal
anchorage.
Ø 4.6 mm
(1)
Ø 5.2 mm
(1)
(1)
6.5 mm
8 mm
10 mm
12 mm
14 mm
8 mm
10 mm
12 mm
14 mm
16 mm
18 mm
6.5 mm
8 mm
10 mm
12 mm
(1) ID color codes repeated on instruments and labels.
SPECIFIC DRILLING PROTOCOLS
Ø 2.0
Initial
drill
Ø 3.0
Drill
INSERTION TORQUE COMPARISON
Material with similar properties to low-density bone
Comparative insertion torque tests were performed.
Different implants with proven performance were
inserted into a synthetic material with similar
properties to low-density bone.
Results showed the superiority of the Axiom® PX
implant: the effective insertion torque value was more
rapidly reached, and a higher torque was in the
low-density material.
30
25
Torque (N.cm)
INSERTION TORQUE
TESTS
Ø 4.0 x 12 mm
w Low and medium-density bone.
w Slight sub-drilling is recommended.
w Logical drilling sequence.
w Step drills for centered drilling.
w No tapping.
w Depth gauges available: 1 per drill diameter.
w Easy to grip, no need for an implant holder: less handling!
w Reference markings: for proper orientation of the tri-lobe
feature end vertical positioning of the implant.
w Subcrestal positioning of the implant for an aesthetic result.
20
C
15
Ø 3.4 x 12 mm
G
Ø 3.4 x 12 mm
10
Brand A
Ø 3.5 mm
5
0
Brand B
Ø 3.5 mm
0
2
4
6
8
10
Insertion depth (mm)
12
14
10
anthogyr
B, AN INNOVATIVE CONCEPT
FULLY CONTROLLED
SOLUTION
DEDICATED SURGICAL KIT
w Easy, practical and logical layout.
w Orange color code for the Axiom® 2.8 implant.
w Fully controlled and reproducible
impaction using the SafeLock® calibrated
instrument.
w No adverse effects for the patient!
w Can be used at chair side: connects
directly to a micromotor.
w Innovative and reliable
technique.
w Several tips are available for
straight/angled abutments and
crowns.
w Ergonomic design.
A RELIABLE PROCEDURE
5 impactions are necessary and sufficient to guarantee full seating of the abutment.
0.3
0.25
Insertion (in mm)
Vertical positioning of the
definitive abutment according
to the number of impaction.
0.2
0.15
Recommended number
of impactions
0.1
0.05
0
0
2
4
5
6
Number of impactions
8
11
ACONCEPT,THE
N E W
D I M E N S I O N
COMPREHENSIVE PROSTHETIC RANGE
w 4 angulations: 0°, 7°, 15° and 23°.
w The crown can be cemented extra-orally.
w PEEK temporary abutment.
w One-stage or two-stage surgery using the cover plug.
1.0
mm
2.5
mm
4.0
mm
5.5
mm
4 gingival heights
Constant emergence profile from healing plug to final abutment:
w No undue tension on soft tissue.
Disassembly force
SAFE CALIBRATED
IMPACTION
300
Force in N
Tests showed that a force of 295 N was necessary to
disengage the abutment, which guarantees a strong
reliable connection for the lifetime of the prosthesis*.
350
250
295
200
150
168
147
100
50
*Cement Selection for Cement-Retained Crown Technique with
Dental Implants. James L. Sheets, Charles Wilcox & Terry
Wilwerding - Journal of Prosthodontics - Feb. 2008.
0
B
KetacTM Cem
Cement
Fuji Plus
Cement
12
anthogyr
B, THE INCISIVE CHOICE!
TION
INNOVA
Specially designed for use in the incisor region, in cases of
restricted mesiodistal space.
CONICAL CONNECTION
w Tight seal morse tapered connection with a 1.5° half angle.
A TRUE NARROW «TWO-PART» IMPLANT
w Optimal management of the treatment plan and the soft tissue.
w Preservation of 2,8 diameter even for prosthetic profile.
STRAIGHT THREADED NECK
w Optimized anchorage.
w Retentive neck with bone compaction effect.
CYLINDRICAL-CONICAL SHAPE
w Implant with controlled and guided insertion.
w Atraumatic apex.
2.8 mm
PROGRESSIVE ASYMMETRICAL THREADING
w Self-tapping.
w Gradual bone compaction is achieved during threading.
w Excellent initial stability.
IMPACTED PROSTHESIS
w Controlled and calibrated impaction using the
SafeLock® instrument!
13
ACONCEPT,THE
THE IDEAL IMPLANT FOR THE
AESTHETIC SECTOR
The Axiom® 2.8 implant has a very high strength despite
its narrowness. It has been specially designed for
replacement of narrow incisor teeth, particularly in
patients with dental agenesis.
Its design and its diameter allow placement in thin ridges.
3 lengths are available: 10, 12 and 14 mm.
N E W
D I M E N S I O N
L = 10 mm
L = 12 mm
L = 14 mm
(1)
(1)
(1)
(1) ID color codes repeated on instruments and labels
A SIMPLE DRILLING
PROTOCOL
Ø 2.8 x 12 mm
w Any type of bone.
w Only 2 drills!
w Step drills for centered drilling.
w Tapping is recommended D1 bone type.
w Depth gauges available: 1 per drill diameter.
w Easy to grip, no need for an implant holder: less handling!
w Subcrestal positioning of the implant for an aesthetic
result.
Ø 2.0
Drill
Ø 2.6
Drill
10 000 000
PROVEN STRENGTH
The Axiom® 2.8 system showed a capacity to
whithstand the chewing efforts in the incisor
region.
Endurance test at 128 N
1 000 000
Number of cycles before failure of the
construct. Applied load: 128 N
The mechanical strength of several
implant-abutment assemblies has been tested in
accordance with ISO 14801 and FDA
recommendations.
Tap
(optional)
Ø 2.8
5 000 000
100 000
Anthogyr
10 000
Brand B
Ø 2.4 mm
One-piece
assembly
1 000
100
10
1
Brand A
Ø 3 mm
Screw-retained
axiom®
Ø 2.8 mm
14
anthogyr
ACONCEPT FOR A STRAIGHTFORWARD
PROCEDURE
> Compact, ergonomic surgical kits
> Tilt tray
AXIOM® REG AND AXIOM® PX IMPLANTS:
COMMON SURGICAL KIT
> Common instrumentation for Axiom® REG and Axiom® PX implants.
> Drilling protocol: specific to each implant.
> Set of drill stops.
L TAPS**
DEPTH GAUGES AND PARALLEL
ALIGNMENT GAUGES
MANDREL EXTENSION
MANDREL WRENCH
PROSTHETIC MANDREL
TORQUE WRENCH
MANDRELS + IMPLANT
TIGHTENING WRENCHES
DRILL GUIDE
L** DRILLS
S* DRILLS
ROUND BUR
POINTER DRILL
*S : short **L : long.
15
ACONCEPT,THE
N E W
D I M E N S I O N
> Intuitive reading of protocols
> ID color code for each implant diameter
AXIOM® 2.8, DEDICATED SURGICAL KIT
THREADED GRIPPER
WRENCH
> A new threaded gripper wrench (OPCF100) is available
for easy insertion of cover plugs, healing plugs, and
PEEK temporary abutments.
PREHENSILE WRENCH
> Abutments can be inserted using the prehensile
wrench (OPOP028) in one single pressure.
DEPTH GAUGE
ROUND BUR
FREE GROMMETS AVAILABLE FOR
ADDITIONAL INSTRUMENTS
POINTER DRILL
MANDREL + IMPLANT
TIGHTENING WRENCH
Ø 2.0 mm INITIAL DRILL
MANDREL EXTENSION
Ø 2.6 mm STEPWISE DRILL
Ø 2.8 mm TAPPING DEVICE
REVERSIBLE
RATCHET WRENCH
MANDREL HOLDING WRENCH
simeda
customized
&
E
solutions
D
F
Photo credit: Anthogyr - All rights reserved - Non contractual photos
IMPLANTEO®a
C141B - 2013-11
A
®
2237 Avenue André Lasquin
74700 Sallanches - France
Phone +33 (0)4 50 58 02 37
Fax +33 (0)4 50 93 78 60
www.anthogyr.com

Similar documents

Guiding System®

Guiding System® > B. SURGICAL PROTOCOL The anthogyr Guiding System for axiom® system offers a simple surgical protocol. On the one hand, it guarantees rapid and effective use of the device, with perfect mastering ...

More information

ANTHOGYR Guiding System

ANTHOGYR Guiding System Practitioners who use the system are responsible for the monitoring and maintenance required to detect and treat complications, and for ensuring proper functioning and safety of the device at an ap...

More information