ACONCEPT
Transcription
ACONCEPT
PERFORMANCE, FREEDOM, SIMPLICITY A CONCEPT G C B The new dimension 2 anthogyr A: 1 GLOBAL CONCEPT, 1 TRULY COMPR An ergonomically designed and exhaustive range that offers the best solution for D E F * ISO 5832-2 standard « Implants for surgery – Metallic materials» - part 2, ISO 5832-3 standard «Implants for surgery – Metallic materials» - part 3 ** As per recommended protocol *** Data on file at Anthogyr 3 ACONCEPT,THE N E W D I M E N S I O N EHENSIVE RANGE, 3 COMPLEMENTARY OPTIONS EVERY clinical indication CONICAL, STRONG AND TIGHT SEAL CONNECTION w w w w w Morse tapered connection. Even distribution of mechanical stresses. No micromotions: no bacterial infiltration. Preservation of alveolar bone. Subcrestal positioning for an aesthetic result. « PLATFORM-SWITCHING » w Preservation of cortical bone. w Optimized biomechanical behavior. w BCP®-treated neck and platform for enhanced osteoconduction. w Higher mechanical strength than Grade IV titanium, and reduced risk of breakage (860 MPa vs 550 MPa)*. w Less invasive: smaller diameter implant used in the same site.** w Proven biocompatibility. EFFECTIVE STIMULATION OF BONE w Optimized use of the threaded surface area. w Minimal stress concentration at tip threads. w Optimal conversion of occlusal loads into compressive forces which stimulate bone formation. E w Optimized bone anchorage. GRADE V TITANIUM (FDA APPROVED, ASTM B34808) w Preservation of the biological space. w Gingival management, mucous «O-Ring». w Epithelial preservation. w Preservation of alveolar crest bone height. F SANDBLASTED THREADED NECK BCP® (BIPHASIC CALCIUM PHOSPHATE) OSTEOCONDUCTIVE SURFACE BCP® grit-blasted surfaces w High biocompatibility: fast and effective osseointegration without any contamination of the adjacent tissue. w Optimal surface roughness: enhancement of cell attachment promotes implant stability and ensures rapid osseointegration. w Successful osseointegration is achieved in more than 99% of the cases***: superior cell adhesion and proliferation abilities. SEM observations of Anthogyr BCP® implant surfaces D x 1000 4 anthogyr G E, ONE CONCEPT FOR EVEN COMMON RANGE OF DENTAL RESTORATIONS FOR BOTH AXIOM® REG AND PX IMPLANTS NEW !* DESIGN WIDE CHOICE OF EMERGENCE PROFILES 0.75 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm Ø 3.4 mm 5 hauteurs gingivales Ø 4.0 mm Ø 5.0 mm Ø 6.0 mm 4 diamètres d’émergence CONSTANT EMERGENCE PROFILE Constant emergence profile from healing screw to final abutment: w No undue tension on soft tissue. WIDE SELECTION OF PROSTHETIC SOLUTIONS w Cement-retained, screw-retained, single-unit and multiple-unit restorations, and full-arch restorations. w Stabilization of complete denture. STERILE components for immediate, permanent placement: w Preservation of periodontal attachment. w Preservation of biological width. w Minimal disturbance of soft tissue. * Availability to be confirmed 5 ACONCEPT,THE N E W D I M E N S I O N MORE FREEDOM! SINGLE SURGICAL KIT FOR AXIOM® REG AND PX IMPLANTS COMMON CONNECTION FOR AXIOM® REG AND PX IMPLANTS w Common instrumentation: simple and user-friendly. Intuitive conical connection thanks to a tri-lobe indexation: w Accurate, controlled abutment placement. w Strong, stable connection even at high torque values. w Simple drilling protocol: specific to each Axiom® REG and Axiom® PX implant. w High intraoperative flexibility: the implant is chosen according to the clinical situation. Common connection for all implant diameters: w Whatever the prosthetic component chosen. w The prosthetic diameter is chosen independently from the implant diameter. w Less restrictions, more flexibility! w Compact, ergonomic kit. COMMON CONNECTION A E simeda ® customized & solutions YOUR CAD-CAM SOLUTION! > Implant-supported restorations: • Cement-retained, screw-retained, single-unit and multiple-unit restorations, and full-arch restorations. • Free downloadable implant library for all popular implant systems. > Tooth-supported restorations. > A large selection of materials to fit all types of restoration: Titanium, Cobalt chromium, IPS e.max® CAD*, Zirconia, PMMA and PEEK. *IPS e.max® CAD is a registered trademark of Ivoclar Vivadent. 6 anthogyr G, SIMPLY PERFORMING! Designed for most clinical indications and most practitioners, whether beginners or experts. CONICAL CONNECTION w Sealed morse connection with a 6° half angle. STRAIGHT THREADED NECK w Optimized anchorage. w Retentive neck with bone compaction effect. CYLINDRICAL-CONICAL SHAPE w Implant with controlled and guided insertion. w Simple and intuitive drilling protocol. PROGRESSIVE ASYMMETRICAL THREADING w Self-tapping. w Gradual bone compaction is achieved during threading. w Excellent initial stability. ATRAUMATIC APEX w Well suited for sinus lift procedures. w Apical thread design fits any type of bone. 7 ACONCEPT,THE N E W D I M E N S I O N IMPLANTS AVAILABLE FOR EVERY SITUATION Short implants (6.5 mm or 8.0 mm): w For placement in anterior and posterior regions with limited bone height. Long implants (16 mm or 18 mm) for 3.4 and 4.0 mm diameters: w Prostheses are fixed onto a small number and angled implants placed in the posterior region to obtain optimal anchorage. Ø 3.4 mm Ø 4.0 mm (1) (1) 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm Ø 4.6 mm (1) 6.5 mm 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm 6.5 mm 8 mm 10 mm 12 mm 14 mm Ø 5.2 mm (1) 6.5 mm 6.5 mm 8 mm 8 mm10 mm 10 mm12 mm 12 mm14 mm 14 mm (1) ID color codes repeated on instruments and labels. A SIMPLE DRILLING PROTOCOL Ø 4.0 x 10 mm w Any type of bone. w Simple, logical drilling sequence: same color code for implant and drill. w Step drills for centered drilling. w Tapping is recommended in D1 bone type. w Depth gauges available: 1 per drill diameter. w Easy to grip, no need for an implant holder: less handling! w Reference markings: for proper orientation of the tri-lobe feature and vertical positioning of the implant. w Subcrestal positioning of the implant for an aesthetic result. Ø 2.0 Drill GUIDED SURGERY TION INNOVA Ø 3.0 Drill Ø 3.6 Drill Ø 4.0 Tap (optional) ANTHOGYR Guiding System > Compatible with Axiom® REG*. > Simplant PRO® software: a universal planning system with a user-friendly interface. > Compact surgical kit: includes a unique, small-size centering sleeve. *For 3.4 mm, 4.0 mm and 4.6 mm diameters. 8 anthogyr C, PROMISE OF EXPERTISE In cases of immediate postextraction implant placement, and insertion in low-density bone. Reserved for experienced practitioners. Optimal primary anchorage! CONICAL CONNECTION w Sealed morse connection with a 6° half angle. REVERSE CONICAL NECK w Preservation of cortical bone. w Promotes alveolar bone remodeling. CONICAL SHAPE w Gradual bone condensing effect. w Enhanced initial stability in low-density bone. w Protocol designed for sub-drilling procedure. DEEP, SHARP THREADS w Self-drilling, self-tapping. SYMMETRICAL DOUBLE-THREADS w Threads with controlled and guided insertion in low-density bone. w Easy insertion. FAST PENETRATION APEX w Quick insertion into the bone. w Optimal anchorage on the apical portion. 9 ACONCEPT,THE N E W D I M E N S I O N IMPLANTS AVAILABLE FOR EVERY SITUATION Short implants (6.5 mm) for 4.6 and 5.2 mm diameters: Ø 3.4 mm w For placement in posterior regions with limited bone height and wide alveolars. Ø 4.0 mm (1) 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm Implant lengths up to 18 mm for 3.4 and 4.0 mm diameters: w Prostheses are fixed onto a small number and angled implants placed in the posterior region to obtain optimal anchorage. Ø 4.6 mm (1) Ø 5.2 mm (1) (1) 6.5 mm 8 mm 10 mm 12 mm 14 mm 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm 6.5 mm 8 mm 10 mm 12 mm (1) ID color codes repeated on instruments and labels. SPECIFIC DRILLING PROTOCOLS Ø 2.0 Initial drill Ø 3.0 Drill INSERTION TORQUE COMPARISON Material with similar properties to low-density bone Comparative insertion torque tests were performed. Different implants with proven performance were inserted into a synthetic material with similar properties to low-density bone. Results showed the superiority of the Axiom® PX implant: the effective insertion torque value was more rapidly reached, and a higher torque was in the low-density material. 30 25 Torque (N.cm) INSERTION TORQUE TESTS Ø 4.0 x 12 mm w Low and medium-density bone. w Slight sub-drilling is recommended. w Logical drilling sequence. w Step drills for centered drilling. w No tapping. w Depth gauges available: 1 per drill diameter. w Easy to grip, no need for an implant holder: less handling! w Reference markings: for proper orientation of the tri-lobe feature end vertical positioning of the implant. w Subcrestal positioning of the implant for an aesthetic result. 20 C 15 Ø 3.4 x 12 mm G Ø 3.4 x 12 mm 10 Brand A Ø 3.5 mm 5 0 Brand B Ø 3.5 mm 0 2 4 6 8 10 Insertion depth (mm) 12 14 10 anthogyr B, AN INNOVATIVE CONCEPT FULLY CONTROLLED SOLUTION DEDICATED SURGICAL KIT w Easy, practical and logical layout. w Orange color code for the Axiom® 2.8 implant. w Fully controlled and reproducible impaction using the SafeLock® calibrated instrument. w No adverse effects for the patient! w Can be used at chair side: connects directly to a micromotor. w Innovative and reliable technique. w Several tips are available for straight/angled abutments and crowns. w Ergonomic design. A RELIABLE PROCEDURE 5 impactions are necessary and sufficient to guarantee full seating of the abutment. 0.3 0.25 Insertion (in mm) Vertical positioning of the definitive abutment according to the number of impaction. 0.2 0.15 Recommended number of impactions 0.1 0.05 0 0 2 4 5 6 Number of impactions 8 11 ACONCEPT,THE N E W D I M E N S I O N COMPREHENSIVE PROSTHETIC RANGE w 4 angulations: 0°, 7°, 15° and 23°. w The crown can be cemented extra-orally. w PEEK temporary abutment. w One-stage or two-stage surgery using the cover plug. 1.0 mm 2.5 mm 4.0 mm 5.5 mm 4 gingival heights Constant emergence profile from healing plug to final abutment: w No undue tension on soft tissue. Disassembly force SAFE CALIBRATED IMPACTION 300 Force in N Tests showed that a force of 295 N was necessary to disengage the abutment, which guarantees a strong reliable connection for the lifetime of the prosthesis*. 350 250 295 200 150 168 147 100 50 *Cement Selection for Cement-Retained Crown Technique with Dental Implants. James L. Sheets, Charles Wilcox & Terry Wilwerding - Journal of Prosthodontics - Feb. 2008. 0 B KetacTM Cem Cement Fuji Plus Cement 12 anthogyr B, THE INCISIVE CHOICE! TION INNOVA Specially designed for use in the incisor region, in cases of restricted mesiodistal space. CONICAL CONNECTION w Tight seal morse tapered connection with a 1.5° half angle. A TRUE NARROW «TWO-PART» IMPLANT w Optimal management of the treatment plan and the soft tissue. w Preservation of 2,8 diameter even for prosthetic profile. STRAIGHT THREADED NECK w Optimized anchorage. w Retentive neck with bone compaction effect. CYLINDRICAL-CONICAL SHAPE w Implant with controlled and guided insertion. w Atraumatic apex. 2.8 mm PROGRESSIVE ASYMMETRICAL THREADING w Self-tapping. w Gradual bone compaction is achieved during threading. w Excellent initial stability. IMPACTED PROSTHESIS w Controlled and calibrated impaction using the SafeLock® instrument! 13 ACONCEPT,THE THE IDEAL IMPLANT FOR THE AESTHETIC SECTOR The Axiom® 2.8 implant has a very high strength despite its narrowness. It has been specially designed for replacement of narrow incisor teeth, particularly in patients with dental agenesis. Its design and its diameter allow placement in thin ridges. 3 lengths are available: 10, 12 and 14 mm. N E W D I M E N S I O N L = 10 mm L = 12 mm L = 14 mm (1) (1) (1) (1) ID color codes repeated on instruments and labels A SIMPLE DRILLING PROTOCOL Ø 2.8 x 12 mm w Any type of bone. w Only 2 drills! w Step drills for centered drilling. w Tapping is recommended D1 bone type. w Depth gauges available: 1 per drill diameter. w Easy to grip, no need for an implant holder: less handling! w Subcrestal positioning of the implant for an aesthetic result. Ø 2.0 Drill Ø 2.6 Drill 10 000 000 PROVEN STRENGTH The Axiom® 2.8 system showed a capacity to whithstand the chewing efforts in the incisor region. Endurance test at 128 N 1 000 000 Number of cycles before failure of the construct. Applied load: 128 N The mechanical strength of several implant-abutment assemblies has been tested in accordance with ISO 14801 and FDA recommendations. Tap (optional) Ø 2.8 5 000 000 100 000 Anthogyr 10 000 Brand B Ø 2.4 mm One-piece assembly 1 000 100 10 1 Brand A Ø 3 mm Screw-retained axiom® Ø 2.8 mm 14 anthogyr ACONCEPT FOR A STRAIGHTFORWARD PROCEDURE > Compact, ergonomic surgical kits > Tilt tray AXIOM® REG AND AXIOM® PX IMPLANTS: COMMON SURGICAL KIT > Common instrumentation for Axiom® REG and Axiom® PX implants. > Drilling protocol: specific to each implant. > Set of drill stops. L TAPS** DEPTH GAUGES AND PARALLEL ALIGNMENT GAUGES MANDREL EXTENSION MANDREL WRENCH PROSTHETIC MANDREL TORQUE WRENCH MANDRELS + IMPLANT TIGHTENING WRENCHES DRILL GUIDE L** DRILLS S* DRILLS ROUND BUR POINTER DRILL *S : short **L : long. 15 ACONCEPT,THE N E W D I M E N S I O N > Intuitive reading of protocols > ID color code for each implant diameter AXIOM® 2.8, DEDICATED SURGICAL KIT THREADED GRIPPER WRENCH > A new threaded gripper wrench (OPCF100) is available for easy insertion of cover plugs, healing plugs, and PEEK temporary abutments. PREHENSILE WRENCH > Abutments can be inserted using the prehensile wrench (OPOP028) in one single pressure. DEPTH GAUGE ROUND BUR FREE GROMMETS AVAILABLE FOR ADDITIONAL INSTRUMENTS POINTER DRILL MANDREL + IMPLANT TIGHTENING WRENCH Ø 2.0 mm INITIAL DRILL MANDREL EXTENSION Ø 2.6 mm STEPWISE DRILL Ø 2.8 mm TAPPING DEVICE REVERSIBLE RATCHET WRENCH MANDREL HOLDING WRENCH simeda customized & E solutions D F Photo credit: Anthogyr - All rights reserved - Non contractual photos IMPLANTEO®a C141B - 2013-11 A ® 2237 Avenue André Lasquin 74700 Sallanches - France Phone +33 (0)4 50 58 02 37 Fax +33 (0)4 50 93 78 60 www.anthogyr.com
Similar documents
Guiding System®
> B. SURGICAL PROTOCOL The anthogyr Guiding System for axiom® system offers a simple surgical protocol. On the one hand, it guarantees rapid and effective use of the device, with perfect mastering ...
More informationANTHOGYR Guiding System
Practitioners who use the system are responsible for the monitoring and maintenance required to detect and treat complications, and for ensuring proper functioning and safety of the device at an ap...
More information