GE Lighting
Transcription
GE Lighting
GE Lighting GE Lighting e and General Electric are both registered trademarks of the General Electric Company, USA 09/2000 English e Lighting Fixtures e e GE Lighting Lighting Fixtures Lighting Fixtures catalogue GE Lighting can offer proper answers for all lighting issues. Our environment needs not only good but efficient lighting, as well. Through using our products, you can get the real solution for your all requirements relating to illumination and in addition, your costs will decrease considerably. GE Lighting is constantly developing and improving its products. For this reason, all product description in this catalogue are intended as a general guide, and we may change some specifications from time to time in the interest of product improvement. By presenting this detailed information about GE lighting fixtures, our aim is to help our customers to arrange the illumination of their environments in the best way. If you have any further question, please contact our local representative in your region on phone number in the back cover of this catalogue. Bulgaria GE Hungary Rt. Representative Office Kv. Krasno Selo ul. Debar Bl. 10 VH.A./IV. 1680 Sofia Tel: (359) 2 59 63 22 Fax: (359) 2 59 63 22 Romania GE Romania SRL Besta Center Str. Constantin Apostol nr. 10, etaj 4, Sector 6 Bucuresti Tel: (40) 1 413 3328 2247 Fax: (40) 1 413 5386 CIS GE Hungary Rt. Representative Office Kosmodamianskaya nab. 52 Building 1, 6th Floor Moscow 113054, Russia Tel: (7) 095 935 7281 Fax: (7) 095 935 7279 Slovakia GE Hungary Rt. Representative Office Prievozska 14/A 82109 Bratislava Tel: (421) 7 5823 8185 Fax: (421) 7 5823 8186 Croatia GE Hungary Rt. Representative Office Marticeva 73 1000 Zagreb Tel: (386) 61 474 4562 Fax: (386) 61 431 6216 info@geadria.si GE Lighting Plant Cavazzale (Vicenza) – Italy Czech Republic GE Lighting, s.r.o. Jihlavská 2 664 41 Brno-Troubsko Tel: (420) 5 472 27951 Fax: (420) 5 472 27955 Estonia, Latvia, Lithuania GE Hungary Rt. Representative Office in the Baltic States Elizabetes 2 LV 1340 Riga, Estonia Tel: (371) 7 321 710 Fax: (371) 7 321762 GE Lighting Plant Coslada (Madrid) – Spain Slovenia GE Adria d.o.o. Dunajska 22 1511 Ljubljana Tel: (386) 61 474 4562 Fax: (386) 61 431 6216 info@geadria.si Ukraine General Electric Co. 42/14 Shelkovichnaya str. Kiev 252003 Tel: (38) 044 490 6983 Fax: (38) 044 490 6982 Yugoslavia GE Hungary Rt. Representative Office Kolarceva 7 11000 Beograd Tel: (381) 11 324 8239 Fax: (381) 11 324 8432 Hungary GE Hungary Rt. Váci út 77. H-1340 Budapest Tel: (36) 1 399 1100 Fax: (36) 1 399 1672 Kazakhstan GE Hungary Rt. Representative Office 153 Abaya Avenue, ap. 14 480024 Almaty Tel: (7) 3272 509 833 Fax: (7) 3272 400 558 Macedonia GE Hungary Rt. Representative Office Belasica BB Skopskie Saem 81000 Skopje Tel: (389) 70 217 649 Fax: (389) 91 386 125 GE Lighting Plant Hendersonville, North Carolina – USA Poland General Electric Co. Polska Sp.z.o.o. ul. Szwolezerów 10 00-464 Warsaw Tel: (48) 22 8415 201 Fax: (48) 22 8419 365 GE Lighting Web Site www.GELighting.com • GE Lighting is constantly developing and improving its products. For this reason, all product description in this catalogue are intended as a general guide, and we may change some specifications from time to time in the interests of product improvement. • Technical drawings in this catalogue are not to scale. • Dimensions are expressed in mm. GENERAL ELECTRIC offers the expertise, knowledge and support of one of the most successful companies in the world, helping you to expand your business General Electric is a global business. Established over 100 years ago, GE is the only company listed in the DOW JONES INDUSTRIAL INDEX today that was included in the original index of 1896, too. General Electric is a more than $100 billion company with a market valuation of more than $300 billion. General Electric operates in more than 100 countries, with 250 manufacturing plants and more than 270,000 employees. General Electric is committed to achieving worldwide leadership in each of the 12 businesses that it operates. General Electric is committed to providing the highest quality and the most advanced products, spending more than $2 billion annually on R&D. Thomas A. Edison invented the electric lamp and founded the General Electric Company. In over 100 years of developing more efficient lamps, GE Lighting has focused consistently on improving the quality and reducing the cost of light for end users. Edison Day window display 1915 at Rikers Drug Store, 200 Broadway, New York City. On 21 October 1879, Thomas A. Edison produced the first incandescent lamp. In honour of his genius this day became known as “Edison Day” and was widely celebrated all over the United States for many years thereafter. Source: “The General Electric Story” 1876-1986 With its 12 businesses, General Electric operates all over the world; one of them is GE Lighting. As one of the world’s biggest light source manufacturers, GE provides high quality products and services its customers. GE Power Controls GE Lighting GE Capital Service GE Appliances GE Information Service GE Aircraft Engines GE Power Systems GE Transportation NBC GE Plastics GE Medical Systems GE Motors & Industrial Systems g GE Lighting 1 GE Lighting World-wide offers over 20,000 different high quality and high technology products Leading worldwide company – GE Lighting is one of the largest manufacturers of light sources in the world. Product innovation – GE owns over 1,700 patents worldwide for lighting technologies and manufacturing processes. It is a value of GE that make a real difference to the quality of the relationship between us and our partners and customers. more than $3.5 billion business 4 billion light bulbs sold each year 20,000 different light source products world-wide 55 manufacturing facilities around the world (North America, South America, Europe, Asia) world-wide sales, marketing and distribution Commitment In every market where we operate we become a key player through internal investment, strategic alliances and acquisitions – four our customers this means the most innovative products and the most effective support. Excellence We continue to establish “Centres of Excellence” for lamp and luminaire manufacturing, engineering and technological development – delivering advanced products of the highest quality. Innovation We have an unbroken record of innovation in lamp technology – which enables us to provide customers with high performance, cost-efficient lighting solutions. Quality GE Lighting is constantly driving up standards in lamp and luminaire manufacturing, improving reliability for users and reducing maintenance costs. g GE Lighting 2 EUROPIC Up-to-date computer lighting program enabling you to design optimal lighting for any environment EUROPIC is an innovative software package for lighting calculations for any interior, exterior or roadway areas. It can operate in Windows 95 or NT environments and is available on CD-ROM. For displayingand printing, 7 languages (English, French, German, Hungarian, Italian, Portuguese and Spanish) can be chosen. It enables the calculations to be made quickly, exactly and easily. Tutorial and on-line Help belong to the program. The CD contains an Instruction Manual, which can be printed out at any time. As a part of the program, the Photometry Management and the Fundamental Information about Lighting will prove to be useful tools during the work. The program can be used for any irregular shape and size rooms/areas, and at the same time in a library, solutions for rooms with regular and pre-determined shapes, sizes and ceiling structures can be found. All this enable you to design the lighting of any environment absolute freely and easily without approximation and composition techniques should be used which are common in case of traditional lighting design programs. When the calculation is complete, the results can be displayed in illuminace tables and relative graphs (isolux curves, spot and 3D diagrams). For simplifying the evaluation of the lit area, the tables showing different values can be displayed in several adjacent windows on the screen. All design related results can not only be displayed on the screen but printed out, as well, illustrating them by 2 and 3 dimensional drawings. A library including a wide range of furniture can make it possible to reproduce the designs in a more realistic way by showing the shadows of tables, chairs, book cases, stairs, stands, trees, etc. Beyond displaying the lighting engineering design, EUROPIC can also produce a captivating photo-like picture showing the final image with installed luminaires together. In this way, a picture can be prepared about the real arrangement of the room to be lit. Lighting designs g GE Lighting 3 QUALITY AND TECHNOLOGY High quality processes and up-to-date technologies to ensure optimal results GE Lighting is continuously focusing on technical innovations and works day to day on development of innovative products by keeping the highest quality standards. All products are submit to rigorous laboratory tests carried out in the most reputed Italian and international institutes authorised for product certification in the lighting industry. The significant investments made for improving and strengthening of our R & D activities make it possible to fulfil all requirements of our customers. From the first phase, GE Lighting controls the safety, characteristics and quality of the products in its new laboratory where all compliance tests can be made according to the national and international standards. All test equipment and measuring instruments in the laboratory have been chosen in accordance with the highest standards in order to guarantee the maximum reliability of results. Spray test: automatic system for measuring the warming IP test: for measuring the level of protection Inflammability test Outstanding laboratory equipment Digital oscilloscope and photogoniometer g GE Lighting 4 CERTIFICATES Products and processes complying the highest quality standards The quality control system of GE Lighting has been holding UNI EN ISO 9000 Certificate since 1994. All equipment in GE Lighting has CE marking. This mark demonstrates that the equipment complies with the EN Regulations relating to electrical products and these products can freely be sold in the unified European market. For lighting equipment, No. 73/23 (modified by No. 93/68) Low Voltage Equipment and No. 89/336 (modified by No. 93/68 and 93/31) Electromagnetic Compatibility directives are applicable. ENEC Certificate Lighting equipment and their parts holding ENEC (European Norms Electrical Certification) mark can be freely marketed in whole Europe. The ENEC mark has been created on the basis of an agreement of 18 European institutes approved by the Cenelec Mark Committee) and verifies that the product in question complies with the EN Standards. The ENEC mark is accepted by all countries involved in this agreement as an equivalent one to that of their similar local marking. In Italy, IMQ is authorised to give ENEC Certification, which is completed with an additional 03 mark. This means that an Italian institute issued this Certificate. The ENEC Process covers the qualification of the manufacturer (which must have UNI EN ISO 9002 Quality Certification), the approval the product in question and the inspection of the production. The main advantage of this process is that only one certificate has to be obtained instead of several local ones which makes possible the export activities to become more dynamic and to sell products in 18 different markets by possessing only one mark. g GE Lighting 5 MAR MAS MAX MAC page 9 page 10 page 11 page 12 N-Pack NPW N-Pack NPP N-Pack NPQ Accessories page 17 page 18 page 19 page 20 Trunking NAL page 26 Series 5503 Series 5504 MEGA page 24 Optical Accessories Series 5500 page 31 Series 5501 page 32 Series 5502 page 33 page 34 page 35 Series 5506 page 36 NUPLEX page 38 page 30 MULTILITE System 8000 Uplighters page 50 page 44 MULTILITE System 6000 page 52 BRIO page 62 page 80 Q-BULK DIAMOND page 66 page 68 QUAD POCKET 16 page 69 pages 70 - 71 TOP/M TOP/DFC-TOP/DAC TOP/HA TOP/MQF-MQA GESPOT GE EDISON FILTERGLOW LOWMOUNT 400 CONSERVA 250 page 80 page 65 page 81 EUROBAY COMPAK VERSABEAM EUROFLUX HALOPAK MASTERPAK page 86 page 88 page 98 page 100 EURO-7 & 2 EUROSTREET page 107 page 105 Lighting terminology g GE Lighting page 110 6 page 56 CLUB page 64 TOP/FC-TOP/AC MULTILITE System 3000 page 89 page 82 page 90 PF 4 page 101 page 102 WALLIGHTER 175 WALLMOUNT 175 page 108 Standards page 114 page 83 page 92 page 84 CITY - TRIS ELITE page 72 page 85 page 94 EF 2000 page 103 page 109 Technical information Resistence to chemical attack Lighting projects for sports Spare parts Product Codes page 117 page 119 page 120 page 126 page 128 FLAT-STRIPLIGHT page 39 POCKET 11 page 73 STYLO page 40 TOP/2DR pages 74 CONTENTS WATERPROOF CEILING LUMINAIRES INDUSTRIAL LFL LIGHTING COMMERCIAL LFL LIGHTING EUROSTYLO page 41 TOP/DBX page 75 Series 5503 2D page 77 GREENPHOS page 78 SYSTEMS ENERGY SAVING LIGHTING GENUSPOT page 79 DISPLAY LIGHTING INDUSTRIAL HID LIGHTING FLOODLIGHTING STREET LIGHTING INFORMATION g GE Lighting 7 Complete range of ceiling luminaires with IP 65 protection The complete range enables to choose the optimal product suitable for installation environment and lighting requirements. MAX Stainless steel body Smooth glass or polycarbonate cover Semiconcentrated beam MAS Polycarbonate body Smooth polycarbonate cover Concentrated beam MAR Polycarbonate body Polycarbonate cover with prismatic reeding Diffuse beam MAC Fibreglass-reinforced polyester body Fluorescent lamp protected by polycarbonate cover Aluminium reflectors Diffuse beam Concentrated beam with MAC/R reflector RAPIDKIT Accessory for mounting on ceiling Pendant rings (photo of MAR) g GE Lighting 8 MARINER - MAR/P series 105 Length L (mm) 165 Type Fixing Holes D (mm) 105 105 D L MAR/P 118 660 390 MAR/P 136 1270 900 MAR/P 158 1570 900 MAR/P 218 660 390 MAR/P 236 1270 900 MAR/P 258 1570 900 90° MAR/P 136 270.0° 180 180° 0° 0.0° 90.0° γ° 90° MAR/P 236 180° C 180.0° C 270° 150 135 120 γ° 105 105 270.0° 180 0° 270° 150 135 120 105 90 90 40 40 75 75 75 75 80 80 120 60 0.0° 90.0° 105 90 90 180.0° 60 120 60 160 60 ULOR 8,6% Type 15 0 15 cd/klm 30 DLOR 69,8% 30 LOR 78,4% N° and Lamp Type MAR/P ULOR 5,7% Weight (kg) Version Class: I 230V 50Hz 15 MAR/P 136/236 H MAR/P 158/258 H Tfn standard operation 90°C 100°C Class of Temperature * T4 T4 (*) According to Standard IEC 31-8 (in event of failure): T1 = 450°C; T2 = 300°C; T3 = 200°C; T4 = 135°C; T5 = 100°C; T6 = 85°C 160 cd/klm 30 Waterproof ceiling fittings for T8 fluorescent lamps, for total protection against the penetration of foreign objects, water jets from any direction and accidental shocks. Flame and combustion resistance in compliance with IEC 34.21 EN 60598-1, totally self-extinguishing V2. Ideal for installation in humid and/or dusty areas. Perfect for AD-FT ambients with inflammability temperature > 150°C. Body: shatterproof Lexan® polycarbonate (resisting shocks above 500 J/sqm according to ASTM 256), grey RAL 7035, self-extinguishing V2; features polyurethane foam seals applied without the use of Freon. Cover: transparent shatterproof self-extinguishing V2 Lexan® polycarbonate, injection moulded anti-ageing UV-stabilised, with high-luminous efficacy linear prismatic reeding on the inside. Completely smooth on the outside for easy cleaning. Clips: fibreglass-reinforced nylon, with self-retaining hinged stainless steel joints. Supplied also with steel screws for tamper-proof fitting. Stainless steel clips are available on request. Reflector: bonderised shaped sheet steel with high-reflection white stoved epoxypolyester powder paint finish. Wiring is mounted to it. Remains attached to the fitting by suspension cords during maintenance. Control gear and electric circuit: 230V 50Hz; wired with heat-resistant (HT 90°C), fireretardant cable in compliance with IEC 20-22/II, with explosion-proof capacitor, with built-in discharge resistor, with power factor correction; terminal block with sectioning fuse and cable grommet for wires up to 2.5 mm2. Max. exterior surface temperature of casing: 0 15 DLOR 64,2% Pack Qty. Box Pallet 30 LOR 69,9% Product Code IP 65 Standard accessories: fittings supplied with D 21 mm gasket, cable grommet PG 13.5 and two nylon suspension rings. Installation: 1) Ceiling mount with gasket or with RAPIDKIT accessory. 2) Pendant with rings enclosed. 3) On NAL trunking system with NAL 1023 accessory. Type N° and Lamp Type MAR/P H CL2 Class of Temperature: T4 Version Weight (kg) Pack Qty. Box Pallet Class:0000 IP 65 230V 50Hz Class of Temperature: T4 Product Code MAR/P 118 H 1 x F18 T8 HPF - FUS 1,70 1 121 7004173 MAR/P 118 H CL2 1 x F18 T8 HPF - FUS 1,70 1 121 30294 MAR/P 136 H 1 x F36 T8 HPF - FUS 2,40 1 77 7004175 MAR/P 136 H CL2 1 x F36 T8 HPF - FUS 2,40 1 77 30295 MAR/P 158 H 1 x F58 T8 HPF - FUS 3,50 1 77 7004177 MAR/P 158 H CL2 1 x F58 T8 HPF - FUS 3,50 1 77 30297 MAR/P 218 H 2 x F18 T8 HPF - FUS 2,10 1 77 7004179 MAR/P 218 H CL2 2 x F18 T8 HPF - FUS 2,10 1 77 30298 MAR/P 236 H 2 x F36 T8 HPF - FUS 3,80 1 44 7004181 MAR/P 236 H CL2 2 x F36 T8 HPF - FUS 3,80 1 44 30300 MAR/P 258 H 2 x F58 T8 HPF - FUS 5,30 1 44 7004183 MAR/P 258 H CL2 2 x F58 T8 HPF - FUS 5,30 1 44 30302 Without lamp. MAR/P EB Without lamp. Electronic Class: I 230V 50Hz IP 65 MAR/P H EES 1 x F18 T8 1,55 1 121 1 x F36 T8 HPF - FUS 2,24 1 77 MAR/P 158 EB 1 x F58 T8 HPF - FUS 2,92 1 MAR/P 218 EB 2 x F18 T8 HPF - FUS 1,58 MAR/P 236 EB 2 x F36 T8 HPF - FUS MAR/P 258 EB 2 x F58 T8 HPF - FUS MAR/P 136 EB With electronic ballast - Without lamp. Note the resistance to chemical agents in construction materials, • HPF = with power factor correction • FUS = with fuse Class: I 230V 50Hz HPF - FUS MAR/P 118 EB Emergency Class of Temperature: T6 30242 MAR/P 118 H ENS* 30243 MAR/P 136 H EES 77 30245 1 77 3,14 1 3,92 1 IP 65 Class of Temperature: T4 1 x F18 T8 HPF - FUS 1,75 1 121 33627 1 x F36 T8 HPF - FUS 3,45 1 77 30224 MAR/P 158 H EES 1 x F58 T8 HPF - FUS 4,70 1 77 30227 30248 MAR/P 218 H EES° 2 x F18 T8 HPF - FUS 2,55 1 77 30237 44 30249 MAR/P 236 H EES° 2 x F36 T8 HPF - FUS 4,85 1 44 30239 44 30253 MAR/P 258 H EES° 2 x F58 T8 HPF - FUS 6,50 1 44 30240 With emergency battery - Without lamp. * Wired for non-permanent operation. ° Only one lamp on emergency. g GE Lighting 9 MARINER - Series MAS/P 185 144 D Length L (mm) Type L MAS/P 158 1570 1200 MAS/P 258 1570 1200 90° MAS/P158 270.0° 180 180° 0° 0.0° 90.0° γ° 90° MAS/P158AL 180° C 180.0° C 270° 150 135 120 180.0° 0.0° 90.0° 270.0° γ° 105 105 90 90 180 0° 270° 150 135 120 105 105 90 90 75 125 75 75 75 75 150 250 225 60 Fixing Hole D (mm) 60 375 60 300 60 500 cd/klm 30 15 ULOR 1,2% 0 15 cd/klm 30 DLOR 80,5% 30 LOR 81,7% 90° MAS/P258 γ° 0.0° 90.0° 270.0° 180 30 LOR 82,9% 90° 180° 270° 150 135 15 C 0° γ° 120 105 105 90 180.0° 0.0° 90.0° 270.0° 180 0° 270° 150 135 120 105 105 90 90 75 75 90 75 75 75 75 150 150 225 60 0 DLOR 81,9% MAS/P258AL 180° C 180.0° 15 ULOR 1,0% 60 225 60 300 30 15 300 Type 0 15 cd/klm 30 DLOR 70,5% 30 LOR 71,5% N° and Lamp Type MAS/P Version Class: I 230V 50Hz 15 ULOR 1,0% Weight (kg) Standard version Version EB Version EES Tfn standard operation 95°C 75°C 95°C Class of Temperature * T4 T6 T4 (*) According to Standard IEC 31-8 (in event of failure): T1 = 450°C; T2 = 300°C; T3 = 200°C; T4 = 135°C; T5 = 100°C; T6 = 85°C 60 cd/klm ULOR 1,0% Waterproof ceiling fittings for T8 fluorescent lamps, for total protection against the penetration of foreign objects, water jets from any direction and accidental shocks. Flame and combustion resistance in compliance with IEC 34.21 EN 60598-1, totally self-extinguishing V2. Ideal for installation in humid and/or dusty areas. Perfect for AD-FT ambients with inflammability temperature > 150°C. Body: shatterproof Lexan® polycarbonate (resisting shocks above 500 J/sqm according to ASTM 256), grey RAL 7035, self-extinguishing V2; features polyurethane foam seals applied without the use of Freon. Cover: transparent shatterproof self-extinguishing V2 Lexan® polycarbonate, injection moulded anti-ageing UV-stabilised. Completely smooth on the outside for easy cleaning. Clips: fibreglass-reinforced nylon, with self-retaining hinged stainless steel joints. Supplied also with steel screws for tamper-proof fitting. Stainless steel clips are available on request. Reflector: bonderised shaped sheet steel with high-reflection white stoved epoxy-polyester powder paint finish, or highly polished aluminium with parabolic profile of concentrated beam (Al). Remains attached to the fitting by suspension cords during maintenance. Control gear and electric circuit: 230V 50Hz wired with heat-resistant (HT 90°C); fireretardant cable in compliance with IEC 20-22/II, with explosion-proof capacitor, with built-in discharge resistor, with power factor correction; terminal block with switching fuse and cable grommet for wires up to 2.5 mm2. Max. exterior surface temperature of casing: 0 15 DLOR 71,7% Pack Qty. Box Pallet 30 LOR 72,7% Product Code Standard accessories: fittings supplied with D 21mm gasket, cable grommet PG 13.5 and two nylon suspension rings. Installation: 1) Ceiling mount with gasket or with RAPIDKIT accessory. 2) Pendant with rings enclosed. 3) On NAL trunking system with NAL 1023 accessory. Type N° and Lamp Type Weight (kg) Version Pack Qty. Box Pallet IP 65 MAS/P H CL2 Class:0000 IP 65 Class of Temperature: T4 With low waste ballast 230V 50Hz Class of Temperature: T4 Product Code MAS/P 158 H 1 x F58 T8 HPF - FUS 4,40 1 28 34163 MAS/P 158 H CL2 1 x F58 T8 HPF - FUS 4,40 1 28 34577 MAS/P 258 H 2 x F58 T8 HPF - FUS 6,20 1 28 34164 MAS/P 258 H CL2 2 x F58 T8 HPF - FUS 6,20 1 28 34578 MAS/P 158 H AL 1 x F58 T8 HPF - FUS 3,70 1 28 34165 MAS/P 158 H AL CL2 1 x F58 T8 HPF - FUS 3,70 1 28 34583 MAS/P 258 H AL 2 x F58 T8 HPF - FUS 5,50 1 28 34166 MAS/P 258 H AL CL2 2 x F58 T8 HPF - FUS 5,50 1 28 34585 Without lamp. MAS/P EB With low waste ballast - Without lamp. Electronic Class: I 230V 50Hz IP 65 MAS/P H EES Emergency Class of Temperature: T6 Class: I 230V 50Hz IP 65 Class of Temperature: T4 MAS/P 158 EB 1 x F58 T8 HPF - FUS 3,82 1 28 34568 MAS/P 158 H EES 1 x F58 T8 HPF - FUS 5,60 1 28 34569 MAS/P 258 EB 2 x F58 T8 HPF - FUS 4,82 1 28 34539 MAS/P 258 H EES° 2 x F58 T8 HPF - FUS 7,40 1 28 34541 MAS/P 158 AL EB 1 x F58 T8 HPF - FUS 3,12 1 28 34579 MAS/P 158 H AL EES 1 x F58 T8 HPF - FUS 4,90 1 28 34581 MAS/P 258 AL EB 2 x F58 T8 HPF - FUS 4,12 1 28 34580 MAS/P 258 H AL EES° 2 x F58 T8 HPF - FUS 6,70 1 28 34582 MAS/P 158 H AL ENS* 1 x F58 T8 HPF - FUS 5,10 1 28 38429 With electronic ballast - Without lamp. g GE Lighting 10 With emergency battery - Without lamp. * Wired for non-permanent operation. ° Only one lamp on emergency. Note the resistance to chemical agents in construction materials. • HPF = with power factor correction • FUS = with fuse MARINER - Series MAX 185 97 MAX/V D L 185 97 120 MAX/P Length L (mm) Type Fixing Holes D (mm) MAX 158 1570 1200 MAX 258 1570 1200 D L 90° MAX/V 158 270.0° 90.0° γ° 180 180.0° γ° 120 105 105 0° 0.0° 270.0° 90.0° 270° 150 135 Standard version Version EB Version EES 180° C 0° 0.0° Class of Temperature * T4 T6 T4 90° MAX/P 158 180° C 180.0° Waterproof ceiling fittings for T8 fluorescent lamps, for total protection against the penetration of foreign objects, water jets from any direction and accidental shocks. Perfect for AD-FT ambients with inflammability temperature > 150°C. Body: pressed from one piece of steel INOX AISI 304, with extremely high mechanic resistance. Cover: MAX/V: 4mm thick tempered glass with high chemical and mechanical resistance fitted in stainless steel frame. MAX/P: transparent shatterproof self-extinguishing V2 Lexan® polycarbonate, injection moulded anti-ageing UV-stabilised. Completely smooth on the outside for easy cleaning. Clips: stainless steel with self-retaining hinged joints. Reflector: polished aluminium with high optical performance. Control gear and electric circuit: 230V 50Hz wired with heat-resistant (HT 90°C); fireretardant cable. Explosion-proof capacitor, with built-in discharge resistor, with power factor correction; terminal block with switching fuse and cable grommet for wires up to 2.5 mm2. Max. exterior surface temperature of casing: 180 270° 150 135 120 105 105 (*) According to Standard IEC 31-8 (in event of failure) T1 = 450°C; T2 = 300°C; T3 = 200°C; T4 = 135°C; T5 = 100°C; T6 = 85°C 90 90 90 75 75 90 75 50 75 75 150 100 225 60 60 150 60 300 60 200 cd/klm 30 15 ULOR 1,4% 0 15 cd/klm 30 DLOR 71,3% 30 LOR 72,7% 15 ULOR 2,4% 90° MAX/V 258 15 0 30 DLOR 75,6% LOR 78% 90° MAX/P 258 180° 180° C 180.0° 270.0° 180 C 0° 0.0° 90.0° γ° 180.0° γ° 120 105 90 90 0° 0.0° 270.0° 90.0° 270° 150 135 105 180 120 75 90 60 150 60 60 200 ULOR 1,2% LOR 65,2% N° and Lamp Type Type MAX EB 30 30 DLOR 64% Electronic Class: I 15 ULOR 1,8% Weight (kg) Version 230V 50Hz Pack Qty. Box Pallet Product Code Class: I IP 65 Class of Temperature: T4 MAX/V 158 H 1 x F58 T8 HPF - FUS 9,00 1 28 37197 MAX/V 258 H 2 x F58 T8 HPF - FUS 10,50 1 28 37198 MAX/P 158 H 1 x F58 T8 HPF - FUS 5,80 1 28 37190 MAX/P 258 H 2 x F58 T8 HPF - FUS 7,00 1 28 37191 N° and Lamp Type Version Weight (kg) cd/klm cd/klm 15 Weight (kg) 75 75 200 0 MAX 230V 50Hz 100 150 Version 105 90 100 15 N° and Lamp Type 50 75 30 Type 270° 150 135 105 50 60 Standard accessories: fittings supplied with cable grommet PG 13.5 and two steel suspension rings. Installation: 1) Ceiling mount with gasket enclosed. 2) Pendant with rings enclosed. 3) On NAL trunking system with NAL 1023 accessory. 0 15 DLOR 64,6% Pack Qty. Box Pallet 30 LOR 66,4% Product Code IP 65 Without lamp. Type MAX EES Emergency Class of Temperature: T6 MAX/V 158 EB 1 x F58 T8 HPF - FUS 8,80 1 28 37199 MAX/V 158 H EES 1 x F58 T8 MAX/V 258 EB 2 x F58 T8 HPF - FUS 10,10 1 28 37200 MAX/V 258 H EES* MAX/P 158 EB 1 x F58 T8 HPF - FUS 5,60 1 28 37192 MAX/P 258 EB 2 x F58 T8 HPF - FUS 6,40 1 28 37193 With electronic ballast - Without lamp. Note the resistance to chemical agents in construction materials. • HPF = with power factor correction • FUS = with fuse Class: I 230V 50Hz Pack Qty. Box Pallet Product Code IP 65 Class of Temperature: T4 9,50 1 28 37201 2 x F58 T8 HPF - FUS HPF - FUS 10,40 1 28 37202 MAX/P 158 H EES 1 x F58 T8 HPF - FUS 6,20 1 28 37194 MAX/P 258 H EES* 2 x F58 T8 HPF - FUS 7,40 1 28 37196 With emergency battery - Without lamp. * Only one lamp on emergency. g GE Lighting 11 MAC 61 Length L (mm) 125 Type 125 125 D L Fixing Holes D (mm) MAC 118 645 500 MAC 136 1265 800 MAC 158 1565 1100 MAC 218 645 500 MAC 236 1265 800 MAC 258 1565 1100 130 130 235 170 Waterproof luminaires for T8 tubular fluorescent lamps offering total protection against the entry of foreign objects, jets of waters from any direction and accidental contact (Class II). Flame and combustion resistant in compliance with IEC 34.21 EN 60598-1. Suitable for installation in damp and/or dusty environments as well as for exterior use. The luminaires are supplied with Ø 38 mm polycarbonate protective tube and VIT 2 starter (FS 2 for MAC 218 version). Body and cover: fibreglass reinforced polyester. Lampholder: self-extinguishing polycarbonate for T8 tubular fluorescent lamps, complete with ring nuts, lampholders clip fit over a seal in cover tube seating. Control gear and electric circuit: wired for 230V 50Hz using cables with silicone insulation, power factor correction using explosion-proof capacitor with built-in discharge resistor; terminal block with 2.5 mm2 clamping screws; VIT 2 safety starter for automatic cut-out of burned out or faulty lamps (FS 2 starter for MAC 218 version). Starters are accessible from outside the luminaire by removing the starter compartment cap in cover. Max. exterior surface temperature of casing: Class of Temperature * T4 T6 T4 Standard version Version EB Version EES (*) According to Standard IEC 31-8 (in event of failure) T1 = 450°C; T2 = 300°C; T3 = 200°C; T4 = 135°C; T5 = 100°C; T6 = 85°C Standard accessories: luminaires are supplied complete with gasket D 21 mm, cable geomet PG 13.5 and two nylon suspension rings. Installation: 1) Ceiling mount with gasket or with RAPIDKIT accessory. 2) Pendant with rings enclosed. 3) On NAL trunking system with NAL 1023 accessory. 90° MAC136+MAC/R4 270.0° 90.0° γ° 180 180.0° γ° 120 105 105 90 270.0° 180 270° 150 135 120 105 105 90 90 75 75 90 75 150 150 225 60 225 60 60 300 300 cd/klm cd/klm 30 15 0 15 30 30 15 0 15 30 LOR 81,6% LOR 84,3% Type MAC/R Using reflectors for ceiling luminaires enables to control the light distribution and to provide high utilization factor in rooms of high interior heights or where task lighting are also installed. MAC/R AL – polished aluminium reflector fixed to the body by stainless steel spring, enclosed. 75 75 75 60 0° 0.0° 90.0° 270° 150 135 180° C 0° 0.0° 90° MAC236+MAC/R24 180° C 180.0° N° and Lamp Type MAC Version Class: 0000 230V 50Hz Weight (kg) Pack Qty. Box Pallet Product Code IP 65 Type With Luminaire Length L (mm) Weight (kg) Pack Qty. Box Product Code MAC/R AL Polished aluminium reflector Class of Temperature: T4 MAC 118 H 1 x F18 T8 HPF 1,60 1 MAC/R 2 AL MAC 118 650 0,36 5 33039 1 x F36 T8 HPF 2,30 1 300 150 7004287 MAC 136 H 7004288 MAC/R 4 AL MAC 136 1255 0,70 5 33041 MAC 158 H 1 x F58 T8 HPF 3,00 1 150 7004289 MAC/R 5 AL MAC 158 1555 0,90 5 33048 MAC 218 H 2 x F18 T8 HPF 2,00 1 240 7004290 MAC/R 22 AL MAC 218 650 0,45 5 33052 MAC 236 H 2 x F36 T8 HPF 3,80 1 120 7004291 MAC/R 24 AL MAC 236 1255 0,90 5 33053 MAC 258 H 2 x F58 T8 HPF 4,80 1 120 7004292 MAC/R 25 AL MAC 258 1555 1,14 5 33054 Without lamp. Available also with electronic ballast (EB). g GE Lighting 12 Reflector made of steel sheet with white paint finish available, too. Note the resistance to chemical agents in construction materials. • HPF = with power factor correction MARINER Accessories Accessories for quick installation of Mariner (MAR, MAS) luminaires on ceiling. The kit contains two clips. Type Weight (kg) Pack Qty. Box Product Code RAPIDKIT – 2 clips RAPIDKIT 0,20 50 34610 Applications for Mariner - designed by Europic software MAR MAS MAX g GE Lighting 13 Photometric data MAR/P 136 MAS/P 158 AL POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.086 DLOR 32 0.698 60 82 LOR 0.784 88 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 78 SPACING – HEIGHT RATIO SHR NOM 1.75 SHR MAX 1.94 SHR MAX TR 90° C 180° 0° ULOR 2.58 180.0° 0.0° 90.0° 270.0° γ° 150 180 105 90 40 75 80 120 60 160 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.430 0.368 0.321 0.407 0.353 0.311 0.385 0.338 0.301 0.444 0.377 0.326 0.418 0.359 0.314 0.10 0.10 0.20 0.20 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C CIE FLUX CODE 4.00 0.662 0.624 0.589 0.627 0.595 0.566 0.595 0.568 0.543 0.704 0.659 0.619 0.656 0.619 0.586 5.00 0.686 0.652 0.621 0.650 0.622 0.595 0.617 0.593 0.571 0.731 0.691 0.655 0.680 0.648 0.618 SHR NOM SHR NOM 135 150 180 105 90 40 75 80 120 60 160 cd/klm 30 0.057 DLOR 37 0.642 65 85 LOR 0.698 91 1.50 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.397 0.343 0.301 0.379 0.331 0.294 0.362 0.320 0.287 0.410 0.351 0.306 0.389 0.337 0.298 0.10 0.10 0.20 0.20 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 75 250 375 60 500 cd/klm 30 CIE FLUX CODE 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.575 0.524 0.485 0.562 0.517 0.481 0.550 0.509 0.477 0.594 0.536 0.493 0.577 0.526 0.487 0.10 0.10 0.20 0.20 (cd/1000 lm) CIE FLUX CODE ULOR 90° 1.73 SHR MAX TR 2.09 180.0° 0.0° 0,87 SHR MAX TR 0,81 ROOM INDEX 1.50 2.00 3.00 0.666 0.716 0.770 0.623 0.679 0.742 0.588 0.648 0.717 0.651 0.699 0.752 0.613 0.668 0.727 0.582 0.640 0.706 0.636 0.683 0.735 0.603 0.656 0.714 0.575 0.632 0.695 0.695 0.752 0.815 0.643 0.707 0.778 0.603 0.669 0.748 0.672 0.725 0.783 0.628 0.687 0.753 0.592 0.655 0.727 4.00 0.798 0.778 0.754 0.779 0.759 0.741 0.761 0.745 0.730 0.848 0.818 0.792 0.814 0.789 0.768 5.00 0.815 0.796 0.777 0.795 0.779 0.764 0.777 0.763 0.750 0.869 0.844 0.821 0.833 0.812 0.793 90.0° 270.0° CIE FLUX CODE 0.010 51 DLOR 0.717 LOR 0.726 85 97 98 72 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 1.86 SHR MAX TR 2.13 UTILISATION FACTOR – UF (Floor) γ° ROOM INDEX 1.50 2.00 3.00 0.475 0.521 0.575 0.426 0.476 0.538 0.386 0.438 0.505 0.453 0.497 0.549 0.410 0.458 0.517 0.375 0.425 0.489 0.432 0.474 0.527 0.396 0.441 0.498 0.365 0.413 0.473 0.496 0.547 0.608 0.439 0.495 0.564 0.396 0.452 0.527 0.468 0.515 0.572 0.421 0.472 0.536 0.382 0.435 0.504 4.00 0.606 0.574 0.545 0.579 0.552 0.527 0.553 0.531 0.510 0.644 0.606 0.573 0.605 0.574 0.546 5.00 0.626 0.598 0.573 0.599 0.575 0.553 0.573 0.553 0.535 0.667 0.634 0.605 0.627 0.599 0.575 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 0 15 0.012 DLOR 46 0.805 81 96 LOR 0.816 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.526 0.484 0.452 0.514 0.478 0.449 0.504 0.472 0.446 0.543 0.496 0.460 0.528 0.486 0.454 0.10 0.10 0.20 0.20 98 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 81 C SPACING – HEIGHT RATIO 0° SHR NOM ROOM INDEX 1.50 2.00 3.00 0.599 0.640 0.682 0.564 0.609 0.659 0.536 0.584 0.638 0.586 0.625 0.666 0.555 0.599 0.646 0.530 0.577 0.628 0.573 0.611 0.651 0.547 0.589 0.634 0.524 0.570 0.619 0.625 0.671 0.721 0.582 0.634 0.691 0.549 0.604 0.666 0.605 0.648 0.694 0.569 0.617 0.669 0.539 0.591 0.647 4.00 0.704 0.685 0.668 0.688 0.672 0.657 0.672 0.659 0.647 0.748 0.724 0.702 0.719 0.698 0.681 5.00 0.718 0.702 0.687 0.701 0.688 0.675 0.685 0.674 0.663 0.766 0.745 0.726 0.734 0.716 0.701 1.75 SHR MAX 1.81 SHR MAX TR 2.20 180.0° 0.0° 90.0° 270.0° 120 135 150 180 90 75 75 150 225 60 300 cd/klm 30 CIE FLUX CODE 0.319 31 DLOR 0.594 LOR 0.913 59 82 65 91 SHR MAX TR 2.72 180° SPACING – HEIGHT RATIO 0° SHR NOM 2.00 SHR MAX 2.03 270° γ° 0 15 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.558 0.507 0.467 0.545 0.499 0.464 0.533 0.492 0.460 0.577 0.519 0.475 0.559 0.508 0.469 0.10 0.10 0.20 0.20 UTILISATION FACTOR – UF (Floor) γ° ROOM INDEX 1.50 2.00 3.00 0.648 0.698 0.751 0.603 0.660 0.721 0.568 0.628 0.695 0.632 0.681 0.732 0.593 0.648 0.706 0.562 0.619 0.684 0.617 0.664 0.715 0.583 0.636 0.693 0.555 0.611 0.673 0.676 0.732 0.795 0.623 0.686 0.757 0.582 0.648 0.725 0.652 0.705 0.762 0.608 0.667 0.732 0.572 0.634 0.705 4.00 0.780 0.755 0.733 0.760 0.739 0.721 0.742 0.725 0.709 0.828 0.797 0.770 0.794 0.769 0.747 5.00 0.797 0.776 0.757 0.777 0.760 0.744 0.759 0.744 0.730 0.850 0.823 0.800 0.813 0.792 0.772 135 150 165 180 120 150 100 105 50 90 50 75 100 150 60 cd/klm 45 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.387 0.320 0.271 0.346 0.290 0.248 0.307 0.260 0.224 0.398 0.326 0.274 0.353 0.293 0.249 1.00 0.453 0.385 0.333 0.403 0.346 0.302 0.355 0.309 0.272 0.469 0.394 0.338 0.413 0.352 0.306 ROOM INDEX 1.50 2.00 3.00 0.551 0.609 0.678 0.488 0.552 0.630 0.438 0.504 0.588 0.490 0.541 0.603 0.438 0.495 0.565 0.396 0.455 0.531 0.431 0.477 0.544 0.390 0.440 0.502 0.355 0.408 0.475 0.575 0.639 0.717 0.504 0.574 0.661 0.449 0.521 0.614 0.506 0.561 0.628 0.449 0.510 0.585 0.403 0.466 0.547 4.00 0.717 0.676 0.639 0.639 0.606 0.576 0.565 0.539 0.515 0.761 0.713 0.672 0.667 0.630 0.597 5.00 0.742 0.707 0.674 0.662 0.634 0.608 0.587 0.564 0.543 0.791 0.749 0.712 0.693 0.661 0.631 MAC 236 MAS/P 258 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C CIE FLUX CODE 0.010 DLOR 48 0.705 81 96 LOR 0.715 98 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 71 C 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 1.63 SHR MAX TR 1.84 180.0° 0.0° 90.0° 270.0° γ° 135 150 180 105 90 75 75 150 225 60 300 cd/klm g GE Lighting 34 DLOR 0.514 LOR 0.835 63 85 61 83 1.80 SHR MAX TR 2.17 SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 270° UTILISATION FACTOR – UF (Floor) 30 CIE FLUX CODE 0.321 180° 270° 120 SHR MAX NORMAL EFFICIENCY 180° 105 270.0° 0,75 POLAR DIAGRAM OF OUTPUT UTILISATION FACTOR – UF (Floor) 90.0° 180 125 270° 0.0° 82 MAC 136 POLAR DIAGRAM OF OUTPUT 180.0° 150 69 MAS/P 158 270.0° 135 90 UTILISATION FACTOR – UF (Floor) γ° 90.0° 98 270° 270° 0.0° 120 105 SPACING – HEIGHT RATIO 0° 270.0° 180.0° 97 UTILISATION FACTOR – UF (Floor) C 180° 0.0° 120 88 0.829 MAS/P 258 AL POLAR DIAGRAM OF OUTPUT 90.0° LOR SPACING – HEIGHT RATIO 0° γ° ROOM INDEX 1.50 2.00 3.00 0.514 0.566 0.627 0.457 0.513 0.582 0.410 0.469 0.543 0.487 0.535 0.593 0.437 0.490 0.555 0.396 0.451 0.522 0.460 0.506 0.565 0.417 0.468 0.530 0.382 0.434 0.501 0.537 0.594 0.663 0.472 0.534 0.611 0.421 0.484 0.566 0.502 0.555 0.618 0.448 0.504 0.575 0.403 0.462 0.538 MAR/P 236 180.0° 0.819 270° UTILISATION FACTOR – UF (Floor) 135 60 DLOR 180° 270° 120 CIE FLUX CODE 0.010 0 15 14 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 1.00 0.478 0.432 0.396 0.466 0.425 0.393 0.455 0.418 0.389 0.494 0.442 0.402 0.479 0.432 0.397 ROOM INDEX 1.50 2.00 3.00 0.561 0.605 0.654 0.521 0.571 0.627 0.489 0.542 0.604 0.547 0.590 0.638 0.512 0.560 0.614 0.483 0.535 0.594 0.533 0.576 0.622 0.503 0.550 0.603 0.478 0.528 0.585 0.585 0.635 0.692 0.538 0.594 0.658 0.501 0.560 0.630 0.565 0.612 0.664 0.525 0.577 0.636 0.492 0.547 0.612 UTILISATION FACTOR – UF (Floor) γ° 4.00 0.680 0.658 0.638 0.663 0.644 0.627 0.647 0.631 0.617 0.722 0.695 0.670 0.692 0.669 0.649 5.00 0.696 0.678 0.660 0.679 0.663 0.649 0.662 0.649 0.637 0.742 0.719 0.697 0.710 0.691 0.674 135 150 165 120 180 120 80 105 40 90 40 75 80 120 60 cd/klm 45 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.362 0.303 0.260 0.321 0.272 0.236 0.283 0.243 0.213 0.372 0.308 0.262 0.328 0.276 0.238 1.00 0.422 0.363 0.317 0.373 0.324 0.286 0.327 0.287 0.256 0.436 0.371 0.322 0.383 0.330 0.290 ROOM INDEX 1.50 2.00 3.00 0.512 0.564 0.626 0.457 0.515 0.586 0.413 0.474 0.551 0.452 0.498 0.554 0.408 0.460 0.522 0.372 0.426 0.494 0.395 0.436 0.497 0.360 0.405 0.460 0.331 0.378 0.438 0.534 0.592 0.662 0.472 0.536 0.615 0.424 0.490 0.575 0.467 0.516 0.577 0.418 0.473 0.541 0.379 0.436 0.509 4.00 0.661 0.627 0.597 0.585 0.558 0.534 0.514 0.493 0.474 0.702 0.662 0.627 0.611 0.580 0.553 5.00 0.683 0.654 0.627 0.606 0.583 0.561 0.532 0.514 0.498 0.728 0.694 0.662 0.634 0.607 0.583 Photometric data MAC 136 + MAC/R 4 MAX/V 158 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.000 DLOR 44 0.843 79 95 LOR 0.843 100 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° 84 C 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 1.72 ULOR SHR MAX TR 2.05 180.0° 0.0° 90.0° 270.0° γ° 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.478 0.419 0.377 0.467 0.414 0.375 0.458 0.409 0.373 0.491 0.427 0.380 0.478 0.420 0.377 1.00 0.547 0.489 0.444 0.534 0.482 0.441 0.522 0.475 0.439 0.565 0.500 0.451 0.548 0.490 0.447 ROOM INDEX 1.50 2.00 3.00 0.649 0.705 0.766 0.599 0.661 0.732 0.559 0.625 0.702 0.634 0.688 0.748 0.590 0.650 0.718 0.554 0.618 0.693 0.619 0.672 0.731 0.581 0.640 0.706 0.549 0.611 0.683 0.677 0.739 0.810 0.619 0.688 0.768 0.573 0.645 0.732 0.654 0.713 0.779 0.605 0.669 0.744 0.564 0.632 0.713 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 0.0° 90.0° 270.0° 5.00 0.818 0.795 0.773 0.799 0.780 0.761 0.782 0.765 0.749 0.872 0.843 0.816 0.837 0.812 0.790 SHR NOM 120 180 75 75 150 225 60 300 cd/klm 30 CIE FLUX CODE 0.000 DLOR 42 0.816 75 93 LOR 0.816 2.00 96 98 72 2.01 SHR MAX TR 2.25 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.526 0.485 0.453 0.514 0.478 0.449 0.504 0.471 0.446 0.543 0.496 0.460 0.528 0.486 0.455 0.10 0.10 0.20 0.20 100 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° C SHR NOM 1.75 SHR MAX 1.79 ULOR 81 SHR MAX TR 2.11 ROOM INDEX 1.50 2.00 3.00 0.591 0.634 0.678 0.554 0.603 0.654 0.525 0.577 0.633 0.577 0.619 0.662 0.545 0.592 0.641 0.519 0.569 0.623 0.563 0.604 0.646 0.536 0.581 0.628 0.513 0.561 0.613 0.616 0.665 0.718 0.573 0.627 0.687 0.538 0.596 0.660 0.596 0.641 0.689 0.558 0.609 0.664 0.528 0.582 0.642 4.00 0.702 0.682 0.664 0.684 0.667 0.652 0.668 0.654 0.641 0.745 0.720 0.698 0.715 0.694 0.676 5.00 0.716 0.699 0.684 0.698 0.684 0.671 0.681 0.670 0.659 0.763 0.742 0.722 0.731 0.713 0.697 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.012 46 DLOR 0.640 LOR 0.652 81 97 98 65 1.74 SHR MAX TR 2.07 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 270° UTILISATION FACTOR – UF (Floor) γ° 150 180 105 90 75 75 150 225 60 300 cd/klm 30 150 90 SPACING – HEIGHT RATIO 0° 135 105 180° 135 81 UTILISATION FACTOR – UF (Floor) 270° 120 0.727 MAX/V 258 POLAR DIAGRAM OF OUTPUT C LOR SPACING – HEIGHT RATIO 0° γ° 4.00 0.798 0.770 0.745 0.779 0.755 0.734 0.762 0.742 0.724 0.848 0.813 0.783 0.814 0.785 0.760 MAC 236 + MAC/R 24 180.0° 0.713 270° UTILISATION FACTOR – UF (Floor) 135 46 DLOR 180° 270° 120 CIE FLUX CODE 0.014 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.533 0.477 0.435 0.521 0.471 0.432 0.509 0.464 0.429 0.551 0.489 0.442 0.534 0.479 0.437 0.10 0.10 0.20 0.20 UTILISATION FACTOR – UF (Floor) γ° ROOM INDEX 1.50 2.00 3.00 0.625 0.678 0.736 0.576 0.635 0.702 0.536 0.599 0.672 0.610 0.661 0.719 0.567 0.624 0.689 0.531 0.592 0.663 0.595 0.646 0.702 0.558 0.614 0.677 0.526 0.586 0.655 0.652 0.711 0.779 0.595 0.660 0.737 0.550 0.619 0.701 0.629 0.685 0.748 0.581 0.643 0.714 0.541 0.606 0.683 4.00 0.768 0.740 0.715 0.750 0.726 0.705 0.733 0.713 0.695 0.816 0.782 0.751 0.783 0.755 0.730 5.00 0.788 0.764 0.742 0.769 0.750 0.731 0.752 0.735 0.719 0.840 0.810 0.784 0.805 0.781 0.759 120 135 150 180 105 90 50 75 100 150 60 200 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 1.00 0.442 0.398 0.363 0.431 0.391 0.360 0.420 0.385 0.357 0.457 0.407 0.369 0.442 0.398 0.364 ROOM INDEX 1.50 2.00 3.00 0.523 0.567 0.614 0.485 0.534 0.589 0.455 0.507 0.567 0.510 0.552 0.598 0.477 0.524 0.576 0.449 0.499 0.558 0.497 0.538 0.584 0.468 0.514 0.565 0.444 0.493 0.548 0.546 0.595 0.650 0.501 0.556 0.618 0.466 0.523 0.591 0.526 0.572 0.623 0.488 0.539 0.597 0.457 0.511 0.574 4.00 0.639 0.618 0.600 0.622 0.605 0.589 0.607 0.592 0.579 0.679 0.653 0.630 0.650 0.629 0.610 5.00 0.655 0.638 0.622 0.638 0.624 0.610 0.622 0.610 0.598 0.698 0.676 0.656 0.667 0.649 0.633 MAX/P 158 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.024 44 DLOR 0.756 LOR 0.780 78 95 96 78 1.95 SHR MAX TR 2.26 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 270° UTILISATION FACTOR – UF (Floor) γ° 120 135 150 180 105 90 50 75 100 150 60 200 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.518 0.467 0.428 0.503 0.458 0.423 0.490 0.450 0.418 0.535 0.478 0.435 0.516 0.466 0.428 0.10 0.10 0.20 0.20 ROOM INDEX 1.50 2.00 3.00 0.604 0.653 0.706 0.560 0.615 0.676 0.524 0.583 0.650 0.587 0.634 0.686 0.549 0.602 0.660 0.517 0.573 0.637 0.571 0.617 0.668 0.537 0.589 0.645 0.509 0.564 0.625 0.630 0.685 0.747 0.578 0.640 0.710 0.538 0.602 0.678 0.606 0.658 0.714 0.562 0.619 0.683 0.526 0.587 0.657 4.00 0.735 0.710 0.688 0.714 0.693 0.674 0.694 0.677 0.661 0.781 0.750 0.723 0.746 0.720 0.698 5.00 0.753 0.732 0.712 0.731 0.714 0.697 0.711 0.696 0.682 0.802 0.776 0.752 0.765 0.743 0.724 MAX/P 258 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 180° 0.018 45 DLOR 0.646 LOR 0.664 78 95 97 66 1.68 SHR MAX TR 2.05 SPACING – HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 270° UTILISATION FACTOR – UF (Floor) γ° 120 135 150 180 105 90 50 75 100 150 60 200 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 1.00 0.422 0.377 0.343 0.410 0.370 0.339 0.398 0.363 0.335 0.436 0.386 0.348 0.420 0.376 0.343 ROOM INDEX 1.50 2.00 3.00 0.499 0.542 0.589 0.461 0.508 0.563 0.430 0.480 0.540 0.485 0.526 0.572 0.451 0.497 0.549 0.424 0.472 0.530 0.471 0.511 0.557 0.442 0.487 0.537 0.418 0.465 0.520 0.521 0.568 0.623 0.476 0.529 0.590 0.441 0.496 0.563 0.501 0.545 0.595 0.463 0.512 0.569 0.431 0.483 0.546 4.00 0.614 0.592 0.573 0.596 0.578 0.562 0.580 0.565 0.551 0.652 0.625 0.602 0.623 0.601 0.582 5.00 0.630 0.611 0.595 0.612 0.597 0.582 0.595 0.582 0.570 0.671 0.648 0.628 0.640 0.621 0.605 g GE Lighting 15 N-PACK and Accessories NPD diffuser for single-lamp luminaires Trunking NAL Dim. 46 x 68 mm Polycarbonate overtube NPGT with reeding for NPP/NPQ Smooth NPGTL for NPP/NPQ Smooth NPGTW for NPGW NPS/P - NPS/Q wire guard NPT reflector for single- and twin-lamp luminaires NPT reflector for singlelamp luminaires NPR reflector for single- and twin-lamp luminaires NPGR louvre for NPR 4/5 and NPT 24/25 g GE Lighting 16 NPR reflector for twin-lamp luminaires NPA asymmetric reflector N-PACK NPW 4 5 IP 50 116 Length L (mm) Type Fixing Holes D (mm) 91 91 D L NPW/X 118 620 343 NPW/X 136 1230 950 NPW/X 158 1530 1250 NPW/X 218 620 343 NPW/X 236 1230 950 NPW/X 258 1530 1250 High IP 54 protection class luminaires for T8 fluorescent lamps. Cover and attachments can be fitted quickly without tools, cutting installation and maintenance costs. Suitable for AD-FT ambients; in this case NPGTW polycarbonate overtube and VIT 2 Rapidstart safety starter should be used. Body and cover: bonderised cold-rolled steel, thickness 5/10 mm for body, 6/10 mm for cover with a white epoxy-polyester powder paint finish. Cover is mounted on the body using special wing nuts. Lampholder: polycarbonate, fitted to the body by a safety clip; complete with soft LOMOD® ring nuts to ensure an effective seal and prevent any danger of the lamp failing; the “rotor” system enables continuous mounting of the luminaires. Control gear and electric circuit: wired for 230V 50Hz using cables with silicon sleeves; power factor correction using explosion-proof capacitor and built-in discharge resistor; terminal block with 2.5 mm2 clamping screws. The control gear circuit wiring is located on a removable sheet plate located inside the luminaire. Max. exterior surface temperature of casing: Tfn standard operation 70°C 90°C 70°C 90°C NPW/X 136 NPW/X 158 NPW/X 236 NPW/X 258 Class of temperature* T5 T4 T5 T4 (*) According to Standard IEC 31-8 (in event of failure): T1 = 450°C; T2 = 300°C; T3 = 200°C; T4 = 135°C; T5 = 100°C; T6 = 85°C Cable entry: using special hole in body through D18 grommet or through knockouts at the end of the fittings. Seals: expanded polyurethane resin between the body and cover plate; rubber between lampholder and luminaire body. Type N° and Lamp Type NPW/X Version Class: I 230V 50Hz Weight (kg) Pack Qty. Box Pallet Product Code IP 54 Class of Temperature: T4 NPW/X 118 H 1 x F18 T8 HPF 1,40 4 324 7004256 NPW/X 136 H 1 x F36 T8 HPF 2,25 4 180 7004257 NPW/X 158 H 1 x F58 T8 HPF 2,90 4 180 7004258 NPW/X 218 H 2 x F18 T8 HPF 1,50 4 168 30082 NPW/X 236 H 2 x F36 T8 HPF 3,30 4 112 7004259 NPW/X 258 H 2 x F58 T8 HPF 4,60 4 112 7004260 Multipack - Without lamp. Type NPW EB N° and Lamp Type Electronic Weight (kg) Version Class: I 230V 50Hz Pack Qty. Box Pallet Product Code Type N° and Lamp Type NPW EES Emergency IP 54 Version Class: I 230V 50Hz Class of Temperature: T6 Weight (kg) Pack Qty. Box Pallet Product Code IP 54 Class of Temperature: T4 NPW 136 EB 1 x F36 T8 HPF 2,00 1 144 32393 NPW 136 EES 1 x F36 T8 HPF 2,75 1 144 30081 NPW 158 EB 1 x F58 T8 HPF 2,40 1 144 32394 NPW 158 EES 1 x F58 T8 HPF 3,40 1 144 7004323 NPW 236 EB 2 x F36 T8 HPF 2,60 1 96 30083 NPW 258 EB 2 x F58 T8 HPF 3,40 1 96 30086 NPW 258 EES* 2 x F58 T8 HPF 5,10 1 96 32146 With electronic ballast - Without lamp. Note the resistance to chemical agents in construction materials. • HPF = with power factor correction With emergency battery - (*one lamp on emergency) - Without lamp. g GE Lighting 17 N-PACK NPP Length L (mm) Type 50 116 91 91 D L N° and Lamp Type Type NPP NPP 115 470 315 NPP 118 620 470 NPP 130 925 605 NPP 136 1230 800 NPP 158 1530 800 NPP 218 620 470 NPP 236 1230 800 NPP 258 1530 800 Weight (kg) Version Class: I Fixing Holes D (mm) Pack Qty. Box Pallet Product Code IP 40 Luminaires for T8 fluorescent lamps for ceiling or trunking installation. Cover and attachments can be fitted quickly without tools, cutting installation and maintenance costs. Body and cover: bonderised cold rolled 5/10 mm sheet steel with white epoxypolyester powder paint finish. The cover is clip mounted to the body. Lampholder: polycarbonate, fitted to the body by a safety clip; complete with ring nuts as a further safety feature to guarantee IP40 and to prevent the lamp from fall; the “rotor” system enables continuous mount of luminaires. Starter: positioned to the side of the body, allowing routine maintenance operations without need to remove lamp or accessories. Control gear and electric circuit: 230V 50Hz wired with heat-resistant (HT 90°C), fireretardant cable in compliance with IEC 20-22/II, with explosion-proof capacitor and built-in discharge resistor in the HPF version, with power factor correction; terminal block with 2.5 mm2 clamping screws. Cable entry: using special hole in body through grommet or through knockouts at the end of the fittings. N° and Lamp Type Type NPP/X Class: I 230V 50Hz Weight (kg) Version Pack Qty. Box Pallet Product Code IP 40 230V 50Hz NPP 118 H 1 x F18 T8 HPF 1,30 1 234 7004225 NPP/X 118 H 1 x F18 T8 HPF 1,30 4 324 7004226 NPP 136 H 1 x F36 T8 HPF 2,10 1 144 7004233 NPP/X 136 H 1 x F36 T8 HPF 2,10 4 180 7004234 NPP 158 H 1 x F58 T8 HPF 2,70 1 144 7004238 NPP/X 158 H 1 x F58 T8 HPF 2,70 4 180 7004239 NPP 218 H 2 x F18 T8 HPF 1,40 1 156 7004240 NPP/X 218 H 2 x F18 T8 HPF 1,40 4 168 7004241 NPP 236 H 2 x F36 T8 HPF 3,10 1 96 7004244 NPP/X 236 H 2 x F36 T8 HPF 3,10 4 112 7004245 NPP 258 H 2 x F58 T8 HPF 4,30 1 96 7004249 NPP/X 258 H 2 x F58 T8 HPF 4,30 4 112 7004250 Single pack - Complete with /33 Cool White 4000K lamp. Fourpack - Without lamp. NPP EB NPP EES Electronic Class: I IP 40 Emergency 230V 50Hz Class: I IP 40 230V 50Hz NPP 136 EB 1 x F36 T8 HPF 1,85 1 144 32421 NPP 136 H EES 1 x F36 T8 HPF 2,55 1 144 7004232 NPP 158 EB 1 x F58 T8 HPF 2,20 1 144 33062 NPP 158 H EES 1 x F58 T8 HPF 3,25 1 144 7004237 NPP 236 EB 2 x F36 T8 HPF 2,40 1 96 30066 NPP 258 EB 2 x F58 T8 HPF 3,10 1 96 32189 NPP 258 H EES* 2 x F58 T8 HPF 4,75 1 96 7004248 With electronic ballast - Without lamp. g GE Lighting 18 With emergency battery - (*one lamp on emergency) - Without lamp. Note the resistance to chemical agents in construction materials. • HPF = with power factor correction N-PACK NPQ 50 91 91 Length L (mm) Type 116 L Version without cover specially designed for mounting on NAL trunking using a mechanical and electrical clip system that requires no tools. The electrical connection uses a NAL 1652 terminal socket accessory previously fitted to the NAL trucking. Body and cover: cold-rolled bonderised 5/10 mm sheet steel with a white epoxypolyester powder paint finish. Lampholder: polycarbonate, fitted to the body by a safety clip; complete with ring nuts to ensure IP 40 and provide a further safety measure against the falling lamp; the “rotor” system enables continuous mounting of luminaires. Starter: position on side of body, allowing routine maintenance operations without removing lamp or accessories. Control gear and electrical circuit: 230V 50Hz wired with heat-resistant (HT 90°C), fire-retardant cable in compliance with IEC 20-22/II, with explosion-proof capacitor and built-in discharge resistor (HPF version) with power factor fitting. Quick electric fitting: the system uses a terminal plug mounted in the body for quick electrical connection with the NAL 1652 terminal socket (not included) previously installed on trucking. Quick mechanical fitting: the system comprises a ring nut which forms an integral part of the body, a catch pin coaxial to the ring nut, and a spring clip which fastens to the trucking. Turn the right nut and pin to different positions to fit/release the luminaire or mount accessories. NPQ/X 118 620 NPQ/X 130 925 NPQ/X 136 1230 NPQ/X 158 1530 NPQ/X 218 620 NPQ/X 236 1230 NPQ/X 258 1530 Quick electric fitting NAL 1652 Quick mechanical fitting Type N° and Lamp Type NPQ/X Version Class: I Weight (kg) Pack Qty. Box Pallet Product Code IP 40 230V 50Hz NPQ/X 118 H 1 x F18 T8 HPF 1,20 4 324 7004251 NPQ/X 136 H 1 x F36 T8 HPF 1,80 4 180 7004252 NPQ/X 158 H 1 x F58 T8 HPF 2,30 4 180 7004253 NPQ/X 218 H 2 x F18 T8 HPF 1,30 4 168 30078 NPQ/X 236 H 2 x F36 T8 HPF 2,80 4 112 7004254 NPQ/X 258 H 2 x F58 T8 HPF 3,90 4 112 7004255 Multipack - Without lamp. Type NPQ EB N° and Lamp Type Electronic Weight (kg) Version Class: I Pack Qty. Box Pallet Product Code Type NPQ EES IP 40 N° and Lamp Type Emergency Version Class: I Weight (kg) Pack Qty. Box Pallet Product Code IP 40 230V 50Hz 230V 50Hz NPQ 136 EB 1 x F36 T8 HPF 1,60 1 180 32458 NPQ 136 H EES 1 x F36 T8 HPF 3,25 1 180 32471 NPQ 158 EB 1 x F58 T8 HPF 1,30 1 180 32461 NPQ 158 H EES 1 x F58 T8 HPF 2,75 1 180 32472 NPQ 236 EB 2 x F36 T8 HPF 2,10 1 112 30079 NPQ 258 EB 2 x F58 T8 HPF 2,70 1 112 32470 NPQ 258 H EES* 2 x F58 T8 HPF 4,65 1 112 7004322 With electronic ballast - Without lamp. Note the resistance to chemical agents in construction materials. • HPF = with power factor correction With emergency battery - (*one lamp on emergency) - Without lamp. Terminal block enclosed (no need for NAL 1652). g GE Lighting 19 N-PACK accessories NPT - Metal reflector 94 112 170 128 90° NPP 136 + NPT 4 0.0° 90.0° 270.0° γ° 180 270° 180.0° 0.0° 90.0° 270.0° γ° 120 105 105 180° C 0° 150 135 90° NPP 236 + NPT 24 180° C 180.0° for NPW - NPP - NPQ. Distributes light entirely downwards. Bonderised pressed 5/10 mm steel, with white epoxy-polyester powder paint finish. Possibility of continuous mounting with NPLT alignment clip. 180 0° Type 270° 150 135 With Luminaire Length (mm) Weight (kg) Pack Qty. Product Code 120 105 105 NPT 90 90 90 90 75 75 75 75 75 75 150 150 225 60 60 225 60 300 60 300 cd/klm 30 0 15 15 cd/klm 30 30 LOR 87,7% 0 15 15 30 LOR 82,1% NPT 2 1 x 18 620 0,40 6 32059 NPT 4 1 x 36 1230 0,80 6 7004205 NPT 5 1 x 58 1530 1,00 6 7004308 NPT 22 1/2 x 18 620 0,60 6 32061 NPT 24 1/2 x 36 1230 1,30 6 7004206 NPT 25 1/2 x 58 1530 1,60 6 7004309 NPR - Slotted metal reflector 112 112 170 90° NPP 136 + NPR 4 γ° 180.0° 0.0° 90.0° 270.0° 180 270° γ° 120 105 105 180° C 0° 150 135 90° NPP 236 + NPR 24 180° C 240 for NPW - NPP - NPQ. Shape and dimensions of reflector results high efficiency. Slots prevent “tunnel” effect and eyestrain when shifting vision from bright (work surface) to dim areas (ceiling). Bonderised cold-pressed 5/10 mm sheet steel with white epoxy-polyester paint finish. Possibility of continuous mounting with NPLT alignment clip. 180.0° 0.0° 90.0° 270.0° 180 0° 270° 150 135 120 105 105 Type 90 90 90 75 75 75 75 75 75 150 150 225 60 60 15 0 15 DLOR 83,1% 30 30 LOR 87,7% Weight (kg) Pack Qty. Product Code ULOR 5,7% 15 0 NPR 1/2 x 36 1230 1,30 6 7004203 NPR 5 1/2 x 58 1530 1,60 6 7004204 cd/klm NPR 24 2 x 36 1230 1,60 6 32070 LOR 84,9% NPR 25 2 x 58 1530 2,00 6 7004307 60 300 cd/klm 30 Length (mm) NPR 4 225 60 300 ULOR 4,6% With Luminaire 90 15 DLOR 79,2% 30 NPA - Asymmetric metal reflector 148 81 for NPW - NPP - NPQ. Special light distribution of reflector makes it particularly suitable for asymmetric lighting. Available in single-lamp version only, made of bonderised cold-pressed 5/10 mm sheet steel with white epoxy-polyester powder paint finish. Possibility of continuous mounting with NPLT alignment clip. With Luminaire Length (mm) Weight (kg) Pack Qty. NPA 4 1 x 36 1230 0,80 6 32072 NPA 5 1 x 58 1530 1,00 6 32073 Type Product Code NPA g GE Lighting 20 N-PACK accessories NPGR - Metal louvre Clip fits on NPT twin-lamp reflectors and NPR single-lamp reflectors on single and twinbatten luminaires. Two clip-fit end caps (supplied) close off ends. Bonderised pressed sheet steel with white epoxy-polyester powder paint finish. Combination of louvre and reflector provides effective lamp screening while maintaining light output. Possibility of continuous mounting of luminaires by NPLT alignment clip instead of clipfit end caps. 112 170 90° NPP 136 + NPR 4 + NPGR 24 0.0° 90.0° 270.0° γ° 180 270° 180.0° 0.0° 90.0° 270.0° γ° 120 105 105 90 180 0° 270° 150 135 120 105 105 90 90 75 75 90 75 75 75 75 150 150 225 60 180° C 0° 150 135 90° NPP 236 + NPT 24 + NPGR 24 180° C 180.0° 60 225 60 60 300 300 cd/klm cd/klm 30 0 15 ULOR 4,0% 15 30 30 DLOR 66,5% 15 0 15 With Luminaire Length (mm) Weight (kg) Pack Qty. Product Code NPGR NPGR 24 NPR 4 - NPT 24 1235 0,80 6 7004311 NPGR 25 NPR 5 - NPT 25 1535 1,00 6 7004312 30 LOR 68,2 % LOR 70,5% Type NPD - Methacrylate diffuser for NPP - NPQ Designed for single-lamp luminaires, features internal longitudinal prismatic reeding. Mount with two clip-fit end caps included in pack. 95 55 90° NPP 136 + NPD 4 180° C 180.0° 0.0° 90.0° 270.0° γ° 180 120 165 0° 270° 150 135 120 150 100 Type 105 105 50 90 90 75 45 30 15 0 15 30 Product Code NPP-NPQ 1 x 18 625 0,20 6 32075 NPD 4 NPP-NPQ 1 x 36 1235 0,35 6 32079 LOR 87,6% NPD 5 NPP-NPQ 1 x 58 1535 0,42 6 32088 60 DLOR 60,8% Pack Qty. cd/klm 150 ULOR 26,9% Weight (kg) NPD 2 100 60 Length (mm) NPD 50 75 With Luminaire 45 NPGT - Overtube with reeding interior finish for NPP - NPQ NPGTL - Overtube with smooth interior finish for NPP - NPQ NPGTW - Overtube with smooth interior finish for NPW Shatterproof self-extinguishing polycarbonate. Supplied complete with 2 ring nuts for mounting on lampholders. Replace universal starter (FSU) with Rapid safety starter (VIT 2) when using overtube. Type 90° NPP 136 + NPGT 4 270.0° 90.0° γ° 180 120 165 180.0° γ° 135 120 270.0° 180 120 0° 165 NPP-NPQ 1/2 x 18 620 0,13 12/1 32090 NPP-NPQ 1/2 x 36 1230 0,24 12/1 32093 NPGT 5 NPP-NPQ 1/2 x 58 1530 0,29 32095 NPGTL 2 NPP-NPQ 1/2 x 18 620 0,13 12/1 12/1 NPGTL 4 NPP-NPQ 1/2 x 36 1230 0,24 12/1 38436 NPGTL 5 NPP-NPQ 1/2 x 58 1530 0,29 12/1 38437 NPGTW 2 NPW 1/2 x 18 620 0,12 12/1 32099 cd/klm NPGTW 4 NPW 1/2 x 36 1230 0,22 12/1 32101 LOR 86,1% NPGTW 5 NPW 1/2 x 58 1530 0,27 12/1 32102 120 105 105 50 90 90 90 75 75 90 50 40 75 120 60 150 60 60 cd/klm ULOR 26,0% 15 0 15 DLOR 61,5% 30 45 LOR 87,5% 38434 75 100 80 30 Product Code NPGT 4 135 100 105 40 Pack Qty. 270° 150 150 80 105 45 Weight (kg) NPGT 2 0.0° 90.0° 270° 150 120 60 180° C 0° 0.0° Length (mm) NPGT / NPGTL / NPGTW 90° NPP 236 + NPGT 4 180° C 180.0° With Luminaire 45 ULOR 31,8% 30 15 0 15 DLOR 54,3% 30 45 g GE Lighting 21 N-PACK accessories NPS - Wire guard 110 65 110 128 Electrically welded steel wire with polished galvanised finish. Hinge opening for lamp changes. Available in two versions: NPS/P with nickel-plated brackets fitted to rear of NPP and NPW fittings. NPS/Q with nickel-plated steel brackets for mounting on NPQ and NPW luminaires by the ring nut of quick mechanical mount device. Type With Luminaire Length (mm) Weight (kg) Pack Qty. Product Code NPS/P - NPS/Q NPS/P 2 NPP-NPW 1 x 18 620 0,30 6 32110 NPS/P 4 NPP-NPW 1 x 36 1230 0,40 6 32112 NPS/P 5 NPP-NPW 1 x 58 1530 0,50 6 32113 NPS/P 22 NPP-NPW 2 x 18 620 0,40 6 32116 NPS/P 24 NPP-NPW 2 x 36 1230 0,60 6 32120 NPS/P 25 NPP-NPW 2 x 58 1530 0,70 6 32122 NPS/Q 2 NPQ-NPW 1 x 18 620 0,30 6 32124 NPS/Q 4 NPQ-NPW 1 x 36 1230 0,40 6 32125 NPS/Q 5 NPQ-NPW 1 x 58 1530 0,50 6 7004306 NPS/Q 22 NPQ-NPW 2 x 18 620 0,40 6 32128 NPS/Q 24 NPQ-NPW 2 x 36 1230 0,60 6 32133 NPS/Q 25 NPQ-NPW 2 x 58 1530 0,70 6 32124 TCGR - End cap Polycarbonate end cap for NPR 4 & 5 and NPT 24 & 25 reflectors. Type Pack Qty. Product Code TCGR TCGR 1 32135 NPLT - Alignment clip for NPT - NPR - NPA reflectors Click-fit polycarbonate alignment clip. Type Pack Qty. Product Code NPLT NPLT g GE Lighting 22 1 32136 N-PACK applications - designed by Europic software NPW NPP NPQ g GE Lighting 23 Trunking NAL Load bearing ceiling-mounted or suspended trunking system for lighting installations. Load-bearing body is made of bondarised 8/10 mm sheet steel with white epoxy-polyester powder paint finish. Various types of luminaires can be installed using the following accessories: • NAL 1652 terminal socket for rapid electrical fitting of NPQ series luminaires. • NAL 1023 suspension bracket for NPP, NPW, MARINER, MAC and other luminaires with mounting holes min. Ø 5 mm. Follow the instructions supplied in the pack. IP 40 NAL system Limit load conditions: Admissible deflection F = L/300 Maximum load q max = 6 kg/m Max. distance between suspension centres L max = 3000 mm 46 32 68 NAL 1030 NAL 1110 NAL 1003 NAL 1027 NAL 1023 NAL 1050/1100 NAL 1026 NAL 1004 NAL 1002 NAL 1025 NAL 1008 NAL 1004 NAL 1652 NAL 1014 NAL 1007 NAL 1001 g GE Lighting 24 NAL 1006 Trunking NAL 100 02 306 000 68 5 Weight Pack Product (kg) Qty. Code Type 180 0 12 Trunking section 46 250 1,380 4 32559 NAL 2000 2,760 4 7004209 NAL 3000 4,140 4 7004210 NAL 1001 20 44 78 68 NAL 1002 30 35 46 20/1 NAL 1003 0,250 30 32624 NAL 1023 NAL 1023 0,030 100/2 32621 100/1 32617 5/1 7004213 50/1 32615 Ø2 5 Ø6 6 7004316 Trunking suspension chain NAL 1025 75 NAL 1025 0,065 ma x 3000 NAL 1003 38 188 0,455 End cap 40 Code Ø 5 mm suspension bracket for light fittings 44 NAL 1002 38 Product Qty. NAL 1001 NAL 1000 Straight joint 15 Pack (kg) White self-extinguishing PVC cover strip NAL 66 Weight Type 49 0,020 100/1 32566 Power supply set 188 NAL 1030 Suspension bracket for hanger or NAL 1025 44 NAL 1030 0,750 NAL 1004 66 NAL 1004 0,040 50/1 Terminal socket for NPQ 7004317 78 78 55 298 NAL 1652 42 Die cast aluminium “L” joint 188 NAL 1652 NAL 1006 NAL 1006 44 0,450 10/1 32570 White steel hanger Die cast aluminium “T” joint 66 NAL 1007 298 0,590 10/1 30 32576 Die cast aluminium “X” joint 75 530 1030 NAL 1008 NAL 1008 NAL 1050 - NAL 1100 Ø6 6 NAL 1007 78 78 0,003 32 0,730 5/1 32580 NAL 1050 0,340 12/1 7004214 NAL 1100 0,560 12/1 7004319 1000 White steel hanger extension 44 NAL 1110 Die cast aluminium “up/down” joint 66 78 78 70 130 NAL 1014 5/1 32586 0,035 100/1 7004318 0,003 100/1 32589 20/1 31753 Ø2 5 NAL 1026 130 NAL 1026 66 30 65 Wire clip 20 38 0,250 0,560 Ceiling bracket 44 38 NAL 1110 NAL 1014 43 10 NAL 1027 NAL 1027 g GE Lighting 25 MEGA Mega is a modular lighting system developed to provide quick and easy installation possibilities for large industrial and commercial areas. Owing to the direct mechanical connection, the 4-pin connecting modules and the low number of joints, the installation is very quick. The product family includes single- and twin-lamp modules of max. 3m length, and steel and aluminium reflectors with louvres. Body: bonderised cold rolled 6/10mm sheet-steel with white epoxy-polyester powder paint finish. Lampholder: polycarbonate with IP 40 protection, which can be improved with MGGT covertube. Covertube: Ø 29mm shatterproof self-extinguishing polycarbonate accessory. Metal reflector: bonderised cold-pressed sheet steel with white epoxy-polyester powder paint finish. Aluminium reflector: cold pressed polished aluminium formed for optimum light output. Aluminium louvre: anodised anti-iridescent anti reflection aluminium featuring parabolic longitudinal reflectors for wide and symmetrical Batwing light distribution and optimum light output. Control gear and electric circuit: 230V 50Hz; starter; wired with Ø 0.50 mm2 section heat-resistant (HT 90°C) cable and with Ø 1.50 mm2 cable for power supply (2 phases + neutral). Lampholders complete with cathode cover to guarantee IP 40 and to prevent the lamp to fall. Installation of modules: suspended with accessory SAC MGG or directly on the ceiling. IP 40 L I D A 86 Dimensions (mm) Type A I L D MG 136 220 1232 1256 900 MG 136 + 136 220 2460 2484 2120 MG 158 220 1532 1556 1200 MG 158 + 158 220 3060 3084 2720 MG 236 220 1232 1256 900 MG 236 + 236 220 2460 2484 2120 MG 258 220 1532 1556 1200 MG 258 + 258 220 3060 3084 2720 Type With Module Weight (kg) Pack Qty. Product Code MGR White steel sheet reflector MGR 4 MG 136/236/136+136*/236+236* 0,80 1 37281 MGR 5 MG 158/258/158+158*/258+258* 1,00 1 37283 * Two reflectors/module. MGR AL Polished aluminium reflector MGR 4 AL MG 136/236/136+136*/236+236* 0,50 1 37282 MGR 5 AL MG 136/236/136+136*/236+236* 0,70 1 37284 * Two reflectors/module. MGO Parabolic aluminium louvre MGO 4/12 EC MG 136/236/136+136*/236+236* 0,50 1 37285 MGO 5/12 EC MG 136/236/136+136*/236+236* 0,70 1 37286 * Two louvres/module. g GE Lighting 26 MEGA N° and Lamp Type Type MEGA Single-lamp Weight (kg) Version Class: I Pack Qty. Box Product Code IP 40 230V 50Hz N° and Lamp Type Type MEGA EB Electronic Weight (kg) Version Class: I Pack Qty. Box Product Code MG 136 1 x F36 T8 HPF 5,50 1 37239 MG 136 + 136 2 x F36 T8 HPF 11,00 1 37247 MG 158 1 x F36 T8 HPF 7,00 1 37240 MG 158 + 158 2 x F36 T8 HPF 14,00 1 37249 Wired modules with power factor correction - Without reflectors - Without lamp. MEGA EES Emergency IP 40 Class: I IP 40 230V 50Hz 230V 50Hz EB 1 x F36 T8 HPF 5,30 1 37241 MG 136 HPF 5,90 1 37244 MG 136 + 136 EB 2 x F36 T8 HPF 10,60 1 37251 MG 136 + 136 EES*2 x F36 T8 HPF 11,40 1 37254 MG 158 EB 1 x F36 T8 HPF 6,60 1 37243 MG 158 HPF 7,40 1 37245 MG 158 + 158 EB 2 x F36 T8 HPF 13,20 1 37253 MG 158 + 158 EES*2 x F36 T8 HPF 14,40 1 37255 MG 136 EES EES 1 x F36 T8 1 x F36 T8 Wired modules with power factor correction and emergency battery - Without reflectors - Without lamp. * One lamp on emergency. Wired modules with power factor correction and electronic ballast - Without reflectors - Without lamp. N° and Lamp Type Type MEGA Twin-lamp Weight (kg) Version Class: I Pack Qty. Box Product Code IP 40 230V 50Hz N° and Lamp Type Type MEGA EB Electronic Weight (kg) Version Class: I Pack Qty. Box Product Code IP 40 MG 236 2 x F36 T8 HPF 6,00 1 37256 MG 236 + 236 4 x F36 T8 HPF 12,00 1 37265 MG 258 2 x F36 T8 HPF 7,60 1 37257 MG 258 + 258 4 x F36 T8 HPF 14,60 1 37266 Wired modules with power factor correction - Without reflectors - Without lamp. MEGA EES Emergency 230V 50Hz MG 236 Class: I IP 40 230V 50Hz EB 2 x F36 T8 HPF 5,60 1 37261 MG 236 EES 2 x F36 T8 HPF 6,40 1 37263 MG 236 + 236 EB 4 x F36 T8 HPF 11,20 1 37267 MG 236 + 236 EES 4 x F36 T8 HPF 12,40 1 37269 MG 258 EB 2 x F36 T8 HPF 7,10 1 37262 MG 258 EES 2 x F36 T8 HPF 8,00 1 37264 MG 258 + 258 EB 4 x F36 T8 HPF 14,20 1 37268 MG 258 + 258 EES 4 x F36 T8 HPF 14,90 1 37270 Wired modules with power factor correction and electronic ballast - Without reflectors - Without lamp. Wired modules with power factor correction and emergency battery - Without reflectors - Without lamp. One lamp on emergency. HPF = with power factor correction MEGA accessories Type Pack Product Qty. Code Pack Product Qty. Code “T” joint Smooth polycarbonate covertube* MGC MGGT MGGT 4 1 37387 MGGT 5 1 37386 * May be used only with Rapidstart safety starter (VIT 2). MGC 1 37275 2 pcs of suspension chain hook, with toothed washer for micrometric adjustment SAC MGG Polycarbonate end cap SAC MGG MGTE MGTE Type 1 37271 1 37272 Suspension set containing two nylon ceiling roses and 2.5m long steel wire SAC MGS Empty steel sheet structural module with cover SAC MGS MG ST Power supply set MG 1232 ST 1 37277 NAL 1030 MG 1532 ST 1 37278 NAL 1030 1 37273 1 7004213 g GE Lighting 27 Photometric data NPP 136 NPP 136 + NPR 4 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.261 DLOR 32 0.684 60 82 LOR 0.945 72 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° 94 C 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 1.95 ULOR SHR MAX TR 2.56 180.0° 0.0° 90.0° 270.0° γ° 165 180 120 150 100 105 50 90 50 75 100 150 60 cd/klm 45 30 LOR 0.878 78 95 94 87 1.81 SHR MAX TR 2.30 SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.411 0.340 0.288 0.374 0.314 0.269 0.340 0.288 0.249 0.422 0.346 0.291 0.383 0.318 0.270 1.00 0.480 0.408 0.352 0.435 0.374 0.327 0.393 0.342 0.301 0.496 0.417 0.358 0.447 0.381 0.330 UTILISATION FACTOR – UF (Floor) γ° 1.50 0.584 0.517 0.463 0.529 0.474 0.428 0.477 0.432 0.393 0.609 0.534 0.475 0.546 0.485 0.436 ROOM INDEX 2.00 3.00 0.645 0.718 0.584 0.667 0.533 0.622 0.585 0.652 0.535 0.610 0.492 0.573 0.528 0.599 0.487 0.555 0.451 0.525 0.677 0.759 0.608 0.700 0.551 0.649 0.606 0.679 0.550 0.632 0.503 0.590 4.00 0.759 0.715 0.676 0.690 0.654 0.622 0.625 0.596 0.570 0.806 0.755 0.710 0.721 0.680 0.644 5.00 0.786 0.748 0.713 0.716 0.685 0.656 0.649 0.624 0.601 0.838 0.793 0.753 0.749 0.714 0.681 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.482 0.421 0.376 0.466 0.412 0.371 0.452 0.403 0.366 0.495 0.428 0.380 0.477 0.417 0.374 1.00 0.554 0.493 0.446 0.535 0.481 0.440 0.517 0.470 0.433 0.572 0.504 0.454 0.549 0.490 0.445 1.50 0.660 0.607 0.565 0.637 0.592 0.555 0.616 0.577 0.544 0.688 0.627 0.580 0.658 0.607 0.565 ROOM INDEX 2.00 3.00 0.717 0.781 0.672 0.745 0.634 0.714 0.693 0.754 0.654 0.724 0.620 0.697 0.670 0.731 0.637 0.704 0.608 0.681 0.752 0.826 0.699 0.782 0.654 0.745 0.718 0.786 0.673 0.750 0.635 0.718 4.00 0.814 0.785 0.759 0.787 0.762 0.740 0.761 0.741 0.722 0.865 0.829 0.797 0.822 0.793 0.767 5.00 0.836 0.811 0.788 0.808 0.788 0.768 0.782 0.764 0.748 0.891 0.860 0.832 0.846 0.820 0.798 NPP 236 + NPR 4 NPP 236 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.331 DLOR 35 0.577 63 85 LOR 0.908 63 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° 90 C 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 1.79 ULOR SHR MAX TR 2.18 180.0° 0.0° 90.0° 270.0° γ° 150 165 180 120 150 100 105 50 90 50 75 100 150 60 cd/klm 45 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.397 0.332 0.285 0.354 0.301 0.261 0.315 0.270 0.237 0.408 0.338 0.288 0.362 0.305 0.263 1.00 0.462 0.397 0.347 0.411 0.357 0.315 0.362 0.319 0.284 0.478 0.406 0.353 0.422 0.363 0.319 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 0.0° CIE FLUX CODE ROOM INDEX 2.00 3.00 0.616 0.683 0.562 0.639 0.517 0.600 0.547 0.607 0.504 0.572 0.467 0.541 0.482 0.548 0.447 0.508 0.418 0.483 0.646 0.723 0.585 0.671 0.534 0.626 0.567 0.633 0.519 0.593 0.477 0.557 4.00 0.721 0.683 0.650 0.641 0.612 0.585 0.567 0.544 0.522 0.766 0.722 0.683 0.670 0.636 0.606 5.00 0.745 0.713 0.683 0.664 0.639 0.615 0.588 0.567 0.548 0.795 0.756 0.721 0.695 0.666 0.639 SHR NOM 120 135 150 90 75 75 150 225 60 300 cd/klm 30 15 0.000 DLOR 43 0.877 77 94 LOR 0.877 SHR NOM γ° 150 180 90 75 75 150 225 60 300 cd/klm 100 1.75 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 270.0° 1.78 ULOR 90° SHR MAX TR 2.11 180.0° 0.0° 90.0° 270.0° 0.75 0.489 0.427 0.382 0.478 0.422 0.380 0.468 0.417 0.378 0.503 0.435 0.385 0.489 0.427 0.382 1.00 0.560 0.498 0.451 0.546 0.491 0.448 0.533 0.484 0.445 0.579 0.510 0.458 0.561 0.500 0.453 1.50 0.666 0.613 0.570 0.650 0.603 0.565 0.635 0.594 0.559 0.695 0.633 0.584 0.671 0.618 0.575 ROOM INDEX 2.00 3.00 0.725 0.790 0.678 0.754 0.639 0.721 0.707 0.771 0.667 0.739 0.632 0.712 0.690 0.754 0.656 0.727 0.625 0.702 0.761 0.836 0.706 0.791 0.660 0.753 0.733 0.803 0.686 0.766 0.647 0.733 CIE FLUX CODE 5.00 0.847 0.822 0.798 0.827 0.806 0.786 0.809 0.791 0.773 0.903 0.871 0.843 0.866 0.839 0.816 SHR NOM 120 135 1.65 SHR MAX TR 1.88 0.10 0.10 0.20 0.20 0.75 0.480 0.422 0.381 0.464 0.413 0.375 0.449 0.404 0.369 0.493 0.430 0.385 0.474 0.419 0.378 1.00 0.546 0.489 0.446 0.526 0.477 0.438 0.508 0.465 0.430 0.564 0.501 0.453 0.540 0.485 0.443 1.50 0.643 0.594 0.555 0.620 0.578 0.543 0.598 0.562 0.532 0.671 0.614 0.569 0.640 0.592 0.553 ROOM INDEX 2.00 3.00 0.696 0.756 0.654 0.722 0.618 0.693 0.671 0.728 0.635 0.700 0.604 0.675 0.647 0.705 0.617 0.679 0.590 0.658 0.731 0.800 0.680 0.758 0.639 0.723 0.696 0.759 0.654 0.725 0.618 0.696 4.00 0.787 0.760 0.735 0.759 0.736 0.715 0.732 0.713 0.696 0.836 0.802 0.772 0.793 0.765 0.741 5.00 0.807 0.784 0.763 0.778 0.759 0.741 0.751 0.735 0.720 0.861 0.832 0.806 0.815 0.791 0.770 75 75 150 225 60 300 cd/klm 30 γ° 180 90 75 75 150 225 300 cd/klm 15 0.051 43 DLOR 0.842 LOR 0.893 76 94 94 89 1.75 SHR MAX 1.75 SHR MAX TR 2.09 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.487 0.424 0.378 0.470 0.414 0.373 0.455 0.405 0.367 0.500 0.431 0.381 0.481 0.420 0.375 1.00 0.558 0.495 0.447 0.538 0.483 0.440 0.519 0.471 0.432 0.576 0.507 0.454 0.552 0.491 0.445 1.50 0.664 0.610 0.566 0.640 0.593 0.555 0.618 0.577 0.544 0.693 0.630 0.580 0.661 0.608 0.565 ROOM INDEX 2.00 3.00 0.722 0.789 0.675 0.751 0.635 0.719 0.697 0.761 0.656 0.729 0.621 0.701 0.673 0.737 0.638 0.708 0.608 0.684 0.758 0.834 0.702 0.789 0.656 0.750 0.722 0.792 0.676 0.755 0.636 0.722 4.00 0.824 0.793 0.766 0.795 0.769 0.746 0.768 0.747 0.727 0.875 0.837 0.804 0.830 0.800 0.772 5.00 0.846 0.820 0.796 0.817 0.796 0.775 0.789 0.771 0.754 0.902 0.870 0.841 0.855 0.829 0.805 0.000 DLOR 46 0.821 79 95 LOR 0.821 100 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 1.50 SHR MAX 1.65 ULOR 90° 82 SHR MAX TR 1.83 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.053 47 DLOR 0.691 LOR 0.744 80 95 92 74 1.68 SHR MAX TR 1.90 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 270° 105 60 180 90 SPACING – HEIGHT RATIO SHR NOM 150 150 105 C 0° g GE Lighting 84 UTILISATION FACTOR – UF (Floor) γ° 4.00 0.825 0.795 0.768 0.805 0.780 0.756 0.787 0.766 0.746 0.876 0.839 0.806 0.841 0.811 0.783 UTILISATION FACTOR – UF (Floor) 30 93 SPACING – HEIGHT RATIO 0° 270° 180° 135 CIE FLUX CODE 180° 270° 120 95 NPP 236 + NPR 4 + NPGT 4 POLAR DIAGRAM OF OUTPUT 90.0° Floor 0.10 CIE FLUX CODE 87 NPP 236 + NPT 24 0.0° 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 (cd/1000 lm) SPACING – HEIGHT RATIO 105 C 79 SHR MAX NORMAL EFFICIENCY UTILISATION FACTOR – UF (Floor) 180.0° 1.50 POLAR DIAGRAM OF OUTPUT 270° 30 180 105 C 0° 135 0.849 UTILISATION FACTOR – UF (Floor) 180° 270.0° 120 LOR NPP 236 + NPR 24 POLAR DIAGRAM OF OUTPUT C 0.792 SPACING – HEIGHT RATIO 0° γ° 1.50 0.559 0.499 0.451 0.496 0.448 0.408 0.437 0.398 0.366 0.583 0.516 0.463 0.513 0.459 0.415 NPP 136 + NPT 4 180.0° 46 DLOR 270° UTILISATION FACTOR – UF (Floor) 135 CIE FLUX CODE 0.057 180° 270° 90.0° 0.831 270° UTILISATION FACTOR – UF (Floor) 150 44 DLOR 180° 270° 135 CIE FLUX CODE 0.046 0 28 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.477 0.421 0.381 0.467 0.417 0.379 0.458 0.412 0.377 0.490 0.429 0.384 0.477 0.422 0.382 1.00 0.542 0.487 0.444 0.530 0.480 0.442 0.518 0.474 0.439 0.560 0.498 0.451 0.543 0.489 0.447 1.50 0.638 0.591 0.552 0.624 0.582 0.548 0.609 0.573 0.542 0.666 0.610 0.567 0.644 0.596 0.557 ROOM INDEX 2.00 3.00 0.691 0.749 0.649 0.716 0.614 0.688 0.674 0.731 0.639 0.703 0.608 0.679 0.659 0.715 0.628 0.691 0.601 0.670 0.725 0.792 0.675 0.752 0.635 0.717 0.699 0.761 0.657 0.728 0.622 0.699 UTILISATION FACTOR – UF (Floor) γ° 4.00 0.779 0.752 0.729 0.761 0.738 0.718 0.744 0.725 0.708 0.828 0.794 0.765 0.795 0.768 0.744 5.00 0.799 0.776 0.755 0.780 0.762 0.744 0.763 0.747 0.732 0.851 0.823 0.798 0.817 0.793 0.772 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.424 0.375 0.339 0.410 0.366 0.334 0.397 0.358 0.328 0.436 0.381 0.342 0.419 0.371 0.336 1.00 0.482 0.433 0.396 0.465 0.422 0.389 0.449 0.411 0.382 0.498 0.443 0.402 0.477 0.430 0.393 1.50 0.566 0.524 0.490 0.546 0.510 0.480 0.526 0.495 0.469 0.591 0.541 0.503 0.564 0.522 0.488 ROOM INDEX 2.00 3.00 0.612 0.664 0.576 0.635 0.545 0.610 0.590 0.639 0.559 0.615 0.532 0.593 0.569 0.618 0.542 0.596 0.519 0.578 0.643 0.702 0.599 0.666 0.563 0.636 0.612 0.666 0.575 0.637 0.544 0.611 4.00 0.691 0.667 0.646 0.665 0.646 0.628 0.641 0.625 0.610 0.734 0.704 0.679 0.695 0.671 0.650 5.00 0.708 0.688 0.670 0.682 0.666 0.650 0.658 0.644 0.631 0.755 0.730 0.707 0.714 0.693 0.675 Photometric data MG136 + MG0 4/12 NPP 236 + NPT 24 + NPGR 24 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.000 DLOR 51 0.682 82 95 LOR 0.682 100 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 68 C 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 1.55 SHR MAX TR 1.79 180.0° 0.0° 90.0° 270.0° γ° 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.424 0.382 0.350 0.416 0.378 0.349 0.409 0.374 0.347 0.436 0.388 0.354 0.426 0.383 0.351 1.00 0.475 0.433 0.401 0.466 0.428 0.399 0.456 0.423 0.396 0.491 0.443 0.407 0.478 0.436 0.403 1.50 0.549 0.513 0.484 0.537 0.506 0.480 0.526 0.498 0.475 0.573 0.530 0.496 0.555 0.518 0.488 ROOM INDEX 2.00 3.00 0.588 0.632 0.557 0.608 0.531 0.586 0.576 0.618 0.549 0.597 0.525 0.578 0.564 0.605 0.540 0.587 0.520 0.571 0.618 0.669 0.580 0.638 0.548 0.611 0.597 0.644 0.565 0.618 0.537 0.596 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 0.0° 90.0° 270.0° SHR NOM 5.00 0.670 0.653 0.637 0.655 0.641 0.627 0.641 0.629 0.617 0.714 0.692 0.673 0.686 0.667 0.651 120 135 150 90 75 75 150 225 60 300 cd/klm 30 CIE FLUX CODE 0.269 DLOR 31 0.608 59 81 LOR 0.876 15 SHR NOM 165 180 150 100 105 50 90 50 75 100 150 60 cd/klm 69 ULOR 90° 87 1.75 SHR MAX 1.96 SHR MAX TR 2.71 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.375 0.309 0.261 0.338 0.282 0.241 0.303 0.257 0.221 0.385 0.314 0.264 0.345 0.286 0.243 1.00 0.438 0.371 0.319 0.393 0.337 0.293 0.351 0.304 0.267 0.452 0.379 0.325 0.403 0.343 0.297 1.50 0.532 0.470 0.420 0.478 0.426 0.384 0.426 0.384 0.349 0.555 0.485 0.430 0.493 0.437 0.391 ROOM INDEX 2.00 3.00 0.588 0.655 0.531 0.607 0.483 0.565 0.528 0.589 0.482 0.550 0.442 0.516 0.472 0.537 0.434 0.495 0.401 0.467 0.617 0.692 0.553 0.637 0.500 0.590 0.547 0.613 0.496 0.570 0.452 0.531 180.0° 0.0° 90.0° 270.0° NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 270.0° 5.00 0.718 0.682 0.649 0.648 0.619 0.592 0.582 0.558 0.536 0.765 0.723 0.686 0.678 0.645 0.615 120 SHR NOM 135 CIE FLUX CODE 75 150 225 60 300 cd/klm 30 0.260 DLOR 31 0.615 59 81 LOR 0.875 SHR NOM 165 180 120 80 105 40 90 40 75 80 120 60 cd/klm 70 15 1.75 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 270.0° CIE FLUX CODE 59 1.25 1.98 SHR MAX TR 2.76 0.75 0.373 0.307 0.259 0.337 0.281 0.239 0.303 0.256 0.220 0.383 0.312 0.261 0.345 0.285 0.241 1.00 0.437 0.369 0.318 0.393 0.336 0.292 0.352 0.305 0.267 0.451 0.378 0.323 0.403 0.342 0.296 0.0° ROOM INDEX 2.00 3.00 0.649 0.681 0.626 0.663 0.607 0.648 0.637 0.668 0.618 0.653 0.601 0.640 0.626 0.656 0.609 0.643 0.595 0.631 0.681 0.721 0.651 0.696 0.627 0.676 0.660 0.696 0.636 0.676 0.615 0.659 4.00 0.698 0.684 0.671 0.684 0.672 0.661 0.671 0.661 0.652 0.742 0.722 0.705 0.715 0.699 0.685 5.00 0.708 0.696 0.685 0.694 0.684 0.674 0.680 0.672 0.664 0.755 0.738 0.723 0.726 0.712 0.700 DLOR 0.640 LOR 0.643 90 98 99 64 1.35 SHR MAX TR 1.47 SHR MAX 165 180 150 100 105 50 90 50 75 100 150 cd/klm 15 1.00 0.467 0.431 0.403 0.458 0.426 0.400 0.450 0.421 0.398 0.483 0.441 0.409 0.470 0.433 0.405 0.10 0.10 0.20 0.20 1.50 0.535 0.504 0.479 0.524 0.497 0.475 0.513 0.490 0.470 0.558 0.520 0.491 0.541 0.509 0.483 ROOM INDEX 2.00 3.00 0.570 0.609 0.544 0.588 0.522 0.571 0.558 0.595 0.536 0.578 0.516 0.563 0.547 0.583 0.528 0.569 0.511 0.555 0.598 0.644 0.566 0.618 0.539 0.595 0.579 0.620 0.551 0.599 0.528 0.580 4.00 0.628 0.612 0.597 0.614 0.601 0.588 0.602 0.590 0.580 0.667 0.646 0.627 0.642 0.624 0.609 5.00 0.640 0.626 0.614 0.626 0.615 0.604 0.613 0.603 0.594 0.682 0.664 0.648 0.655 0.640 0.627 90.0° 270.0° CIE FLUX CODE 0.006 52 DLOR 0.654 LOR 0.661 86 97 99 66 1.65 SHR MAX TR 1.85 SPACING – HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX UTILISATION FACTOR – UF (Floor) ROOM INDEX 2.00 3.00 0.589 0.656 0.531 0.608 0.484 0.566 0.530 0.592 0.483 0.553 0.443 0.518 0.475 0.540 0.436 0.499 0.403 0.471 0.617 0.694 0.553 0.638 0.500 0.591 0.549 0.616 0.497 0.572 0.453 0.534 4.00 0.694 0.653 0.617 0.627 0.594 0.564 0.564 0.537 0.512 0.738 0.690 0.648 0.655 0.617 0.584 5.00 0.720 0.684 0.651 0.651 0.622 0.595 0.587 0.563 0.541 0.767 0.725 0.687 0.681 0.648 0.618 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.465 0.425 0.395 0.455 0.419 0.392 0.445 0.414 0.389 0.480 0.435 0.401 0.467 0.427 0.396 0.10 0.10 0.20 0.20 1.50 0.538 0.505 0.478 0.526 0.497 0.473 0.515 0.489 0.468 0.561 0.521 0.490 0.543 0.509 0.481 ROOM INDEX 2.00 3.00 0.577 0.618 0.548 0.596 0.524 0.576 0.563 0.604 0.539 0.584 0.518 0.568 0.551 0.590 0.530 0.574 0.511 0.560 0.605 0.654 0.570 0.625 0.541 0.601 0.584 0.628 0.555 0.605 0.530 0.585 4.00 0.639 0.621 0.605 0.624 0.609 0.595 0.610 0.598 0.586 0.679 0.656 0.635 0.652 0.633 0.616 5.00 0.653 0.637 0.623 0.637 0.625 0.613 0.623 0.613 0.602 0.696 0.676 0.658 0.667 0.651 0.637 0.318 DLOR 36 0.543 65 86 LOR 0.860 63 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 1.50 SHR MAX 1.74 ULOR 90° 86 SHR MAX TR 2.18 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.003 60 DLOR 0.516 LOR 92 98 99 0.520 51 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 1.84 SHR MAX TR 2.18 270° γ° 60 Floor 0.10 180° γ° 1.50 0.532 0.469 0.419 0.479 0.427 0.385 0.428 0.386 0.351 0.555 0.485 0.430 0.494 0.438 0.391 SPACING – HEIGHT RATIO SHR NOM 120 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 ULOR 90° 180.0° C 0° 30 0.003 CIE FLUX CODE UTILISATION FACTOR – UF (Floor) 45 0.20 (cd/1000 lm) 180° 150 0.20 NORMAL EFFICIENCY 270° 135 0.10 1.50 0.618 0.591 0.569 0.607 0.584 0.565 0.597 0.577 0.560 0.644 0.610 0.584 0.627 0.598 0.575 MG236 + MG0 4/12 POLAR DIAGRAM OF OUTPUT 90.0° 0 87 NPP 236 + NPGT 4 0.0° 1.00 0.560 0.528 0.503 0.551 0.523 0.501 0.543 0.518 0.498 0.578 0.540 0.511 0.566 0.532 0.506 270° 120 C 2.23 0.10 POLAR DIAGRAM OF OUTPUT C γ° 180.0° 180 75 UTILISATION FACTOR – UF (Floor) 30 150 90 SPACING – HEIGHT RATIO 0° 45 SHR MAX TR UTILISATION FACTOR – UF (Floor) 105 180° 150 1.99 SPACING – HEIGHT RATIO 0° 270° 135 70 MG236 + MGR POLAR DIAGRAM OF OUTPUT 90.0° CIE FLUX CODE 180° γ° 4.00 0.693 0.652 0.615 0.624 0.591 0.561 0.559 0.533 0.508 0.736 0.688 0.646 0.652 0.614 0.581 NPP 136 + NPGT 4 0.0° 99 270° 120 C 98 Floor 0.10 CIE FLUX CODE C γ° 180.0° 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 (cd/1000 lm) UTILISATION FACTOR – UF (Floor) 30 92 SHR MAX NORMAL EFFICIENCY SPACING – HEIGHT RATIO 0° 45 1.75 POLAR DIAGRAM OF OUTPUT 180° 150 180 105 270° 135 0.700 MG236 + MGR AL POLAR DIAGRAM OF OUTPUT C LOR UTILISATION FACTOR – UF (Floor) γ° 4.00 0.655 0.635 0.617 0.640 0.623 0.608 0.627 0.613 0.599 0.696 0.670 0.648 0.669 0.648 0.630 NPP 136 + NPD 4 180.0° 0.698 270° UTILISATION FACTOR – UF (Floor) 135 60 DLOR SPACING – HEIGHT RATIO 0° 270° 120 CIE FLUX CODE 180° 0.002 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.382 0.322 0.278 0.341 0.291 0.254 0.303 0.262 0.231 0.392 0.327 0.280 0.349 0.295 0.256 1.00 0.445 0.384 0.337 0.396 0.345 0.307 0.349 0.309 0.277 0.459 0.393 0.343 0.406 0.352 0.310 1.50 0.536 0.481 0.437 0.477 0.432 0.395 0.420 0.385 0.355 0.559 0.497 0.448 0.492 0.443 0.402 ROOM INDEX 2.00 3.00 0.590 0.652 0.540 0.611 0.498 0.576 0.524 0.580 0.485 0.548 0.450 0.519 0.462 0.523 0.430 0.486 0.403 0.463 0.619 0.690 0.562 0.642 0.515 0.601 0.543 0.604 0.499 0.567 0.461 0.535 UTILISATION FACTOR – UF (Floor) γ° 4.00 0.687 0.653 0.622 0.611 0.584 0.560 0.540 0.519 0.499 0.730 0.689 0.653 0.639 0.607 0.580 5.00 0.709 0.680 0.653 0.632 0.609 0.587 0.559 0.540 0.523 0.756 0.721 0.689 0.661 0.634 0.610 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 1.00 0.413 0.389 0.371 0.407 0.385 0.369 0.400 0.381 0.366 0.427 0.398 0.377 0.417 0.392 0.373 1.50 0.457 0.436 0.420 0.449 0.431 0.417 0.441 0.425 0.413 0.476 0.451 0.431 0.463 0.441 0.424 ROOM INDEX 2.00 3.00 0.480 0.504 0.463 0.491 0.449 0.479 0.471 0.494 0.456 0.483 0.444 0.473 0.463 0.485 0.450 0.475 0.439 0.467 0.504 0.534 0.482 0.515 0.463 0.500 0.488 0.515 0.470 0.500 0.454 0.487 4.00 0.517 0.506 0.497 0.506 0.497 0.489 0.496 0.489 0.482 0.549 0.534 0.522 0.529 0.517 0.506 g GE Lighting 5.00 0.525 0.516 0.507 0.514 0.506 0.499 0.503 0.497 0.491 0.559 0.547 0.535 0.538 0.527 0.518 29 SERIES 5000 - Optical accessories 90° C 180.0° 0.0° 90.0° 270.0° 180° 0° 270° 120 135 150 180 150 135 120 105 105 90 90 75 75 60 60 30 120 15 135 150 0 180 15 150 135 30 120 105 105 90 90 75 75 60 60 30 120 15 135 150 0 15 30 180 150 135 120 105 105 90 90 75 75 60 60 30 120 15 135 150 0 15 30 180 150 135 120 105 105 90 90 75 75 60 60 30 120 15 135 150 0 180 15 150 135 120 105 90 90 75 75 60 60 g GE Lighting 30 15 0 15 POLISHED ALUMINIUM LOUVRE - Reference/6 Louvre with broad symmetrical light distribution, featuring longitudinal reflectors, in aluminium with polished finish (99.85%), satin-finished extruded aluminium transverse blades. SATIN FINISH ALUMINIUM LOUVRE - Reference /12 Louvre with broad symmetrical light distribution, featuring parabolic longitudinal reflectors in anodised anti-iridescent satinfinished 99.90% pure aluminium; resistant to fingerprints. Satin-finished, extruded aluminium transverse blades. MIRROR-FINISH ALUMINIUM LOUVRE - Reference /16 Ideal for work environments with video display terminals. Louvre with broad symmetrical Batwing light distribution, featuring longitudinal reflectors and double parabolic transverse blades, in anodised anti-iridescent 99.90% pure aluminium with mirror finish. Direct longitudinal and transverse luminance less than 200 cd/m2 for vertical angles over 60°. 30 105 30 WHITE ALUMINIUM LOUVRE - Reference /5 Louvre with broad symmetrical light distribution, featuring longitudinal reflectors and straight transverse blades, in aluminium with gloss white painted finish. 30 METHACRYLATE DIFFUSER - Reference/51 Acrylic diffuser with prismatic interior mounted on aluminium frame. Series 5500 Series 5500 L2 92 A L1 Dimensions (mm) L1 L2 Type A 5500/218 292 592 622 5500/236 292 1192 1232 5500/318 592 592 622 5500/418 592 592 622 5500/436 592 1192 1232 5500/334/2L 592 592 622 Type N° and Lamp Type 5500/218 Weight (kg) Class: I Pack Qty. Box Pallet Recessed luminaires for mounting on exposed 24 mm T sections of 600mm x 600mm suspended ceilings. Body: press-bent 6/10 mm sheet steel (7.5/10 mm for 4x36 models) with white powder paint finish. Optical accessories: see page 30. Control gear and electric circuit: 230V 50Hz; with starter, HT 90°C heat-resistant hard wires, complete with built-in 2A fuse. Lampholder with covers for IP 40 protection level. SPECIAL VERSIONS: see page 37. Product Code IP 40 230V 50Hz 5500/218/5 H 2 x F18 T8 4,00 1 60 30096 5500/218/6 H 2 x F18 T8 4,00 1 60 31540 5500/218/12 H 2 x F18 T8 4,00 1 60 31435 5500/218/16 H 2 x F18 T8 4,00 1 60 31437 5500/218/51 H 2 x F18 T8 4,00 1 60 31438 H = with power factor correction - Without lamp. 5500/236 Class: I IP 40 Type N° and Lamp Type 5500/418 Weight (kg) Class: I 230V 50Hz Pack Qty. Box Pallet Product Code IP 40 230V 50Hz 5500/236/5 H 2 x F36 T8 6,50 1 40 31442 5500/418/5 H 4 x F18 T8 5,50 1 20 31461 5500/236/6 H 2 x F36 T8 6,50 1 40 30106 5500/418/6 H 4 x F18 T8 5,50 1 20 36898 5500/236/12 H 2 x F36 T8 6,50 1 40 31439 5500/418/12 H 4 x F18 T8 5,50 1 20 36901 5500/236/16 H 2 x F36 T8 6,50 1 40 31440 5500/418/16 H 4 x F18 T8 5,50 1 20 36900 5500/236/51 H 2 x F36 T8 6,50 1 40 31441 5500/418/51 H 4 x F18 T8 5,50 1 20 31460 H = with power factor correction - Without lamp. 5500/318 Class: I H = with power factor correction - Without lamp. IP 40 5500/436 Class: I 230V 50Hz IP 40 230V 50Hz 5500/318/5 H 3 x F18 T8 5,00 1 20 30111 5500/436/5 H 4 x F36 T8 12,00 1 10 30117 5500/318/6 H 3 x F18 T8 5,00 1 20 30113 5500/436/6 H 4 x F36 T8 12,00 1 10 30118 5500/318/12 H 3 x F18 T8 5,00 1 20 31445 5500/436/12 H 4 x F36 T8 12,00 1 10 31464 5500/318/16 H 3 x F18 T8 5,00 1 20 31447 5500/436/16 H 4 x F36 T8 12,00 1 10 31465 5500/318/51 H 3 x F18 T8 5,00 1 20 31547 5500/436/51 H 4 x F36 T8 12,00 1 10 31468 H = with power factor correction - Without lamp. H = with power factor correction - Without lamp. g GE Lighting 31 Series 5501 Series 5501 L2 92 A L1 Dimensions (mm) L1 L2 Type A 5501/418 599 599 622 5501/436 599 1199 1232 5501/334/2L 599 599 622 Luminaires for hidden structure 600mm x 600mm suspended ceilings, complete with micrometric adjustment mounting clips. Body: press-bent 6/10 mm sheet steel (7.5/10 mm for 4x36 models) with white powder paint finish. Optical accessories: see page 30. Control gear and electric circuit: 230V 50Hz; with starter, HT 90°C heat-resistant hard wires, complete with built-in 2A fuse. Lampholder with cathode covers for IP 40 protection level. SPECIAL VERSIONS: see page 37. Type N° and Lamp Type 5501/418 Weight (kg) Class: I Pack Qty. Box Pallet Product Code IP 40 230V 50Hz 5501/418/5 H 4 x F18 T8 5,80 1 20 7004130 5501/418/6 H 4 x F18 T8 5,80 1 20 30131 5501/418/12 H 4 x F18 T8 5,80 1 20 31475 5501/418/16 H 4 x F18 T8 5,80 1 20 31476 5501/418/51 H 4 x F18 T8 5,80 1 20 31477 H = with power factor correction - Without lamp. g GE Lighting 32 Series 5502 for indirect lighting 5502/234/C H 5502/255/C EB 5502/234/L H 5502/255/L EB Series 5502 for indirect lighting 145 C A D L1 Type A 5502 596 Dimensions (mm) C L1 596 D 557 557 Luminaires for mounting on exposed 24 mm T sections of 600 mm x 600 mm suspended ceilings (mounting clips enclosed). Body: press-bent 6/10 mm sheet steel with white powder paint finish. Optical accessories: perforated sheet steel for version /C (with one central lamp) and version /L (with one lamp on both sides). Models for two 34W Biax™ L compact fluorescent lamps (with magnetic ballast) and for two 55W Biax™ L compact fluorescent lamps (with electronic ballast) are available. Control gear and electric circuit: 230V 50Hz; with starter (magnetic ballast), HT 90 °C heat-resistant hard wires, complete with built-in 2A fuse. Lampholder with cathode covers for IP 40 protection level. Type N° and Lamp Type 5502 Weight (kg) Class: I Pack Qty. Box Pallet Product Code IP 40 230V 50Hz 5502/234/C H 2 x F34 BX 8,80 1 20 38414 5502/234/L H 2 x F34 BX 8,80 1 20 38420 5502/255/C EB 2 x F55 BX 8,20 1 20 38423 5502/255/L EB 2 x F55 BX 8,20 1 20 38424 H = with power factor correction - EB = Electronic ballast - Without lamp. CLIPS for micrometric adjustment of Series 5000 Accessories SAC CLIPS 5000 90° 5502/234/C γ° 0.0° 90.0° 270.0° 180 90° 5502/234/L 180° C 180.0° 180° C 0° 270° 150 135 γ° 120 105 105 90 0.0° 90.0° 270.0° 180 0° 270° 150 135 120 105 90 75 75 90 40 30 75 75 80 60 120 60 180.0° 105 90 60 90 60 160 60 120 cd/klm 30 15 0 7003612 15 30 LOR 45,4% cd/klm 30 15 0 15 30 LOR 40,4% g GE Lighting 33 Series 5503 Series 5503 I L2 A1 92 L1 A Type Dimensions (mm) L1 L2 I A A1 5503/118 225 165 685 622 690 5503/136 225 165 1295 1232 1300 5503/158 225 165 1595 1532 1600 5503/218 325 265 685 622 690 5503/236 325 265 1295 1232 1300 5503/258 325 265 1595 1532 1600 5503/418 625 560 625 622 690 Type N° and Lamp Type 5503/118 Weight (kg) Class: I Pack Qty. Box Pallet Product Code IP 40 Luminaires for all types of suspended ceiling (excepting mineral fibre panels) complete with micrometric adjustment mounting clips. Body: 6/10 mm press-bent sheet with white powder paint finish. Optical accessories: see page 30. Control gear and electric circuit: 230V 50Hz; with starter, HT 90 °C heat-resistant hard wires, explosion-proof power factor correction capacitor with built-in discharge resistance; terminal block with 2.5 mm2 clamping screws complete with built-in 2A fuse. Lampholder with cathode covers for IP 40 protection level. SPECIAL VERSIONS: see page 37. Type N° and Lamp Type 5503/218 Weight (kg) Class: I Pack Qty. Box Pallet Product Code IP 40 230V 50Hz 5503/218/5 H 2 x F18 T8 3,70 1 40 30158 5503/218/6 H 2 x F18 T8 3,70 1 40 30565 5503/218/12 H 2 x F18 T8 3,70 1 40 31495 5503/218/16 H 2 x F18 T8 3,70 1 40 31498 5503/218/51 H 2 x F18 T8 3,70 1 40 31499 H = with power factor correction - Without lamp. 5503/236 Class: I 230V 50Hz IP 40 230V 50Hz 5503/118/5 H 1 x F18 T8 3,30 1 80 30136 5503/236/5 H 2 x F36 T8 7,70 1 30 30159 5503/118/6 H 1 x F18 T8 3,30 1 80 30139 5503/236/6 H 2 x F36 T8 7,70 1 30 30160 5503/118/12 H 1 x F18 T8 3,30 1 80 31480 5503/236/12 H 2 x F36 T8 7,70 1 30 31500 5503/118/16 H 1 x F18 T8 3,30 1 80 31562 5503/236/16 H 2 x F36 T8 7,70 1 30 31502 5503/118/51 H 1 x F18 T8 3,30 1 80 31564 5503/236/51 H 2 x F36 T8 7,70 1 30 31503 H = with power factor correction - Without lamp. 5503/136 Class: I H = with power factor correction - Without lamp. IP 40 5503/258 Class: I 230V 50Hz IP 40 230V 50Hz 5503/136/5 H 1 x F36 T8 4,90 1 50 30148 5503/258/5 H 2 x F58 T8 9,50 1 30 30161 5503/136/6 H 1 x F36 T8 4,90 1 50 30153 5503/258/6 H 2 x F58 T8 9,50 1 30 30163 5503/136/12 H 1 x F36 T8 4,90 1 50 31481 5503/258/12 H 2 x F58 T8 9,50 1 30 31567 5503/136/16 H 1 x F36 T8 4,90 1 50 31482 5503/258/16 H 2 x F58 T8 9,50 1 30 31569 5503/136/51 H 1 x F36 T8 4,90 1 50 31484 5503/258/51 H 2 x F58 T8 9,50 1 30 31570 H = with power factor correction - Without lamp. 5503/158 Class: I H = with power factor correction - Without lamp. IP 40 5503/418 Class: I 230V 50Hz IP 40 230V 50Hz 5503/158/5 H 1 x F58 T8 6,10 1 50 30155 5503/418/5 H 4 x F18 T8 7,80 1 20 30165 5503/158/6 H 1 x F58 T8 6,10 1 50 30156 5503/418/6 H 4 x F18 T8 7,80 1 20 30168 5503/158/12 H 1 x F58 T8 6,10 1 50 31486 5503/418/12 H 4 x F18 T8 7,80 1 20 31505 5503/158/16 H 1 x F58 T8 6,10 1 50 31487 5503/418/16 H 4 x F18 T8 7,80 1 20 31506 5503/158/51 H 1 x F58 T8 6,10 1 50 31494 5503/418/51 H 4 x F18 T8 7,80 1 20 31507 H = with power factor correction - Without lamp. g GE Lighting 34 H = with power factor correction - Without lamp. Series 5504 Series 5504 I L2 92 A L1 Dimensions (mm) Type A L2 L1 I 5504/118 186 648 622 675 5504/136 186 1258 1232 1285 5504/158 186 1558 1532 1585 5504/218 286 648 622 675 5504/236 286 1258 1232 1285 5504/258 286 1558 1532 1585 N° and Lamp Type Weight (kg) Pack Qty. Box Pallet Type 5504/118 Class: I Product Code Luminaires with rounded edges for stave-type suspended ceilings with a modular distance of 100 mm, complete with micrometric adjustment mounting clips. Body: 6/10 press-bent sheet steel with stoved white powder paint finish. Optical accessories: see page 30. Control gear and electric circuit: 230V 50Hz; with starter, HT 90 °C heat-resistant hard wires, explosion-proof power factor correction capacitor with built-in discharge resistance; terminal block with 2.5 mm2 clamping screws complete with built-in 2A fuse. Lampholder with cathode covers for IP 40 protection level. SPECIAL VERSIONS: see page 37. Type N° and Lamp Type 5504/218 IP 40 Weight (kg) Class: I Pack Qty. Box Pallet Product Code IP 40 230V 50Hz 230V 50Hz 5504/118/5 H 1 x F18 T8 3,30 1 80 30170 5504/218/5 H 2 x F18 T8 3,70 1 40 30175 5504/118/6 H 1 x F18 T8 3,30 1 80 30171 5504/218/6 H 2 x F18 T8 3,70 1 40 31586 5504/118/12 H 1 x F18 T8 3,30 1 80 31571 5504/218/12 H 2 x F18 T8 3,70 1 40 31525 5504/118/16 H 1 x F18 T8 3,30 1 80 31512 5504/218/16 H 2 x F18 T8 3,70 1 40 31583 5504/118/51 H 1 x F18 T8 3,30 1 80 31572 5504/218/51 H 2 x F18 T8 3,70 1 40 31528 H = with power factor correction - Without lamp. H = with power factor correction - Without lamp. 5504/136 Class: I 5504/236 IP 40 Class: I IP 40 230V 50Hz 230V 50Hz 5504/136/5 H 1 x F36 T8 4,90 1 50 30172 5504/236/5 H 2 x F36 T8 7,70 1 30 30177 5504/136/6 H 1 x F36 T8 4,90 1 50 31574 5504/236/6 H 2 x F36 T8 7,70 1 30 31589 5504/136/12 H 1 x F36 T8 4,90 1 50 31513 5504/236/12 H 2 x F36 T8 7,70 1 30 31530 5504/136/16 H 1 x F36 T8 4,90 1 50 31514 5504/236/16 H 2 x F36 T8 7,70 1 30 31531 5504/136/51 H 1 x F36 T8 4,90 1 50 31520 5504/236/51 H 2 x F36 T8 7,70 1 30 31588 H = with power factor correction - Without lamp. H = with power factor correction - Without lamp. 5504/158 Class: I IP 40 5504/258 Class: I 230V 50Hz IP 40 230V 50Hz 5504/158/5 H 1 x F58 T8 6,10 1 50 30173 5504/258/5 H 4 x F18 T8 9,50 1 30 30179 5504/158/6 H 1 x F58 T8 6,10 1 50 30174 5504/258/6 H 4 x F18 T8 9,50 1 30 30180 5504/158/12 H 1 x F58 T8 6,10 1 50 31575 5504/258/12 H 4 x F18 T8 9,50 1 30 31536 5504/158/16 H 1 x F58 T8 6,10 1 50 31576 5504/258/16 H 4 x F18 T8 9,50 1 30 31537 5504/158/51 H 1 x F58 T8 6,10 1 50 31578 5504/258/51 H 4 x F18 T8 9,50 1 30 31591 H = with power factor correction - Without lamp. H = with power factor correction - Without lamp. g GE Lighting 35 Series 5506 Series 5506 D Ceiling mount luminaires. Body: 6/10 mm cold-rolled sheet steel with white paint powder finish. End caps: white polycarbonate. Optical accessories: see page 30. Control gear and electric circuit: 230V 50Hz; with starter, HT 90°C heat-resistant hard wires, explosion-proof power factor correction capacitor, built-in discharge resistance; terminal block with 2.5 mm2 clamping screws complete with built-in 3.15A fuse. Lampholder with cathode covers for IP 40 protection level. SPECIAL VERSIONS: see page 37. 90 A L Dimensions (mm) L Type A D 5506/118 174 655 400 5506/136 174 1265 900 5506/158 174 1565 1200 5506/218 296 655 400 5506/236 296 1265 900 5506/258 296 1565 1200 Type N° and Lamp Type 5506/218 Weight (kg) Class: I Pack Qty. Box Pallet Product Code IP 40 230V 50Hz Type N° and Lamp Type 5506/118 Weight (kg) Class: I Pack Qty. Box Pallet Product Code IP 40 230V 50Hz 5506/218/5 H 2 x F18 T8 3,90 1 40 7004138 5506/218/6 H 2 x F18 T8 3,90 1 40 7004139 5506/218/12 H 2 x F18 T8 3,90 1 40 30197 5506/218/16 H 2 x F18 T8 3,90 1 40 30200 5506/218/51 H 2 x F18 T8 3,90 1 40 30201 H = with power factor correction - Without lamp. 5506/118/5 H 1 x F18 T8 3,50 1 80 7004132 5506/118/6 H 1 x F18 T8 3,50 1 80 7004133 5506/236 Class: I IP 40 230V 50Hz 5506/118/12 H 1 x F18 T8 3,50 1 80 30181 5506/118/16 H 1 x F18 T8 3,50 1 80 30183 5506/236/5 H 2 x F36 T8 6,50 1 30 7004140 5506/118/51 H 1 x F18 T8 3,50 1 80 30184 5506/236/6 H 2 x F36 T8 6,50 1 30 7004141 5506/236/12 H 2 x F36 T8 6,50 1 30 7004282 5506/236/16 H 2 x F36 T8 6,50 1 30 7004283 5506/236/51 H 2 x F36 T8 6,50 1 30 30217 H = with power factor correction - Without lamp. 5506/136 Class: I IP 40 230V 50Hz H = with power factor correction - Without lamp. 5506/136/5 H 1 x F36 T8 5,50 1 50 7004134 5506/136/6 H 1 x F36 T8 5,50 1 50 7004135 5506/258 Class: I IP 40 230V 50Hz 5506/136/12 H 1 x F36 T8 5,50 1 50 7004279 5506/136/16 H 1 x F36 T8 5,50 1 50 7004280 5506/258/5 H 2 x F58 T8 8,80 1 30 7004142 5506/136/51 H 1 x F36 T8 5,50 1 50 30185 5506/258/6 H 2 x F58 T8 8,80 1 30 7004143 H = with power factor correction - Without lamp. 5506/258/12 H 2 x F58 T8 8,80 1 30 7004285 5506/158 5506/258/16 H 2 x F58 T8 8,80 1 30 7004286 5506/258/51 H 2 x F58 T8 8,80 1 30 30221 Class: I IP 40 230V 50Hz H = with power factor correction - Without lamp. 5506/158/5 H 1 x F58 T8 7,10 1 50 7004136 5506/158/6 H 1 x F58 T8 7,10 1 50 7004137 5506/158/12 H 1 x F58 T8 7,10 1 50 7004281 5506/158/16 H 1 x F58 T8 7,10 1 50 30190 5506/418/6 H 4 x F18 T8 5,50 1 30 33600 5506/158/51 H 1 x F58 T8 7,10 1 50 30196 5506/418/16 H 4 x F18 T8 5,50 1 30 32199 H = with power factor correction - Without lamp. g GE Lighting 36 5506/418 Class: I IP 40 230V 50Hz H = with power factor correction - Without lamp. Series 5000 - Special versions EB EES with electronic ballast Version with autonomous emergency group Version Luminaire EB – Luminaires equipped with electronic ballast (cos ϕ = 0,97) Luminaire EES – Luminaires equipped with autonomous emergency group (1 lamp on emergency) 118 EB 5503 5504 5506 118 EES 5503 5504 5506 136 EB 5503 5504 5506 136 EES 5503 5504 5506 158 EB 5503 5504 5506 158 EES 5503 5504 5506 5506 218 EB 5500 5503 5504 5506 218 EES 5500 5503 5504 236 EB 5500 5503 5504 5506 236 EES 5500 5503 5504 5506 5503 5504 5506 258 EES 5503 5504 5506 5503 5504 5506 418 EES 5503 5504 5506 258 EB 418 EB 5500 5501 EBD 5500 5501 Check the feasibility and delivery conditions with our Customer Service. Check the feasibility and delivery conditions with our Customer Service. with dimmable electronic ballast Version Luminaire EBD with DIMMABLE electronic ballast (cosϕ = 0,97) 118 EBD 5503 5504 5506 136 EBD 5503 5504 5506 158 EBD 5503 5504 5506 5506 218 EBD 5500 5503 5504 236 EBD 5500 5503 5504 5506 5503 5504 5506 5503 5504 5506 258 EBD 418 EBD 5500 5501 Check the feasibility and delivery conditions with our Customer Service. Clips Luminaires 5501 – 5503 – 5504 are supplied complete with micrometric adjustment plastic mounting clips for quick and easy installation. Clip levers can be set to three different positions for adaptation to specific needs. Clip mounting system has been specially designed to allow the luminaires to be mounted from inside without having to remove any adjacent suspended ceiling elements. CLIPS for micrometric adjustment of Series 5000 Accessories SAC CLIPS 5000 7003612 Fuse All 5000 series luminaires are supplied with a terminal block featuring a built-in 2A fuse (3.15A for 5506 version) that isolates units with failures for rapid identification, further enhancing electrical system safety standards. g GE Lighting 37 NUPLEX Hidden mounted luminaires with prismatic diffusers for optimal light distribution, a high level of protection against the entry of solid foreign objects and total protection against any form of accidental contact with parts under voltage. Luminaires can be mounted directly on the ceiling or suspended. Body: bonderised cold-pressed sheet steel with epoxy-polyester powder paint finish. Diffuser: injection-moulded acrylic with prismatic reeding. Control gear and electric circuit: wired for 230V 50Hz using heat-resistant cables; explosion-proof capacitor with built-in discharge resistance; terminal block with 2.5 mm2 clamping screws. D H L A Dimensions (mm) Type A H L D NUA 118 108 86 650 400 NUA 136 NUA 158 108 108 86 86 1250 1550 800 1000 NUA 218 190 67 650 400 NUA 236 190 67 1250 800 NUA 258 190 67 1550 1000 NUA 418 680 80 680 450 N° and Lamp Type Type NUPLEX Weight (kg) Class: I 230V 50Hz 90° 1 x F18 T8 2,40 1 84 38425 2 x F36 T8 3,70 1 63 7004168 NUA 158 H 1 x F58 T8 4,90 1 63 30222 NUA 218 H 2 x F18 T8 2,80 1 66 7004169 NUA 236 H 2 x F36 T8 4,70 1 44 7004170 NUA 258 H 2 x F58 T8 7,80 1 44 7004171 NUA 418 H 4 x F18 T8 7,50 1 22 7004172 180.0° 0.0° 90.0° 270.0° γ° 180 120 165 270° 150 γ° 135 120 225 150 180.0° 0.0° 90.0° 270.0° 180 90° NUA 418 180° C 0° 180° C 0° 270° 150 135 γ° 120 105 105 90 90 180.0° 0.0° 90.0° 270.0° 180 0° 270° 150 135 120 105 105 90 90 105 105 75 40 75 75 75 90 90 75 75 80 150 75 75 75 120 60 60 225 60 60 150 160 225 60 300 60 cd/klm cd/klm 45 30 ULOR 29,3% g GE Lighting 15 0 15 DLOR 52,3% 38 30 45 LOR 81,6% 30 ULOR 14,1% 15 0 15 DLOR 59,1% 30 LOR 73,3% IP 40 CEI 34.21 / EN 60598-1 NUA 136 H 90° NUA 236 180° C Product Code NUA 118 H H = with power factor correction - Without lamp. NUA 136 Pack Qty. Box Pallet cd/klm 30 ULOR 19,8% 15 0 15 DLOR 60.72% 30 LOR 80,5% FLAT - STRIPLIGHT Flat Ultra-slim luminaire for T5 fluorescent lamps Dimensions (mm) A D Type L H FLAT 108 324 70 260 32 FLAT 113 552 70 450 32 H D L A Type N° and Lamp Type FLAT Weight (kg) Pack Qty. Box Pallet Product Code IP 40 Class: I 230V 50Hz CEI 34.21 / EN 60598-1 FLAT 108 L 1 x F8 T5 0,64 6/1 660 7004128 FLAT 113 L 1 x F13 T5 0,64 6/1 462 7004129 The ultra-slim (only 32 mm) fitting family for 8W and 13W T5 fluorescent lamps particularly suited for domestic applications, such as on shelves, in the kitchen, benches, windows, bookcases, notice boards, etc. Body: white self-extinguishing polycarbonate. Diffuser: polycarbonate with internal prismatic reeding. Snap fits to base. Starter: inside the fitting. Replaceable. Control gear and electric circuit: 230V 50Hz without power factor correction, silicon sleeves. All luminaires are fitted with switch and terminal block with 2.5 mm2 clamping screws. Cable entry: through special lateral holes in body with grommet. Fittings are supplied with /33 COOL WHITE 4000 K fluorescent lamps. L = without power factor correction - Complete with lamp. Type N° and Lamp Type Electronic FLAT Weight (kg) Pack Qty. Box Pallet M IP 40 Class: 230V 50Hz Product Code M CEI 34.21 / EN 60598-1 FLAT 108 EB L 1 x F8 T5 0,35 6/1 660 39391 FLAT 113 EB L 1 x F13 T5 0,40 6/1 462 39392 L = without power factor correction - Complete with lamp. Electronic FLAT Electronic version features the following advantages: • Instant lamp starting. • Energy saving up to 20% compared to the standard one, thanks to the lower installed power. • Lower heat emission. • No light flicker or stroboscopic effect, thereby enhancing eyes comfort. • No magnetic fields. • Silent operation. Striplight Indoor luminaires for 35-100W TUNGSRALIN incandescent striplight lamps with 2xS14s cap. Body: steel sheet with white enamel coating. Lampholder: aminoplast resin. Installation and connection: – Position the luminaire on the ceiling or on the wall and mark the two drilling points. – Drill the two holes in the wall and fit the two plugs. – Connect the supply cable into the terminal block. – Position the luminaire against the wall and tighten the expansion screws fully. – Carefully put the lamp into the lampholder. Dimensions (mm) Type STRIPLIGHT 11 Pack Qty. Box Lamp ÖVE Class: 230V 50Hz Product Code IP 40 EN 60598-1 & 2 STRIP E1/60-35 TU 35W S14S 30 cm 10/1 512617 STRIP E1/60-60 TU 60W S14S 30 cm 10/1 512618 STRIP E2/100-60 TU 60W S14S 50 cm 10/1 512619 STRIP E2/100-100 TU 100W S14S 50 cm 10/1 512620 Complete with lamp. g GE Lighting 39 STYLO Ultra-slim fluorescent luminaire family specially designed for home lighting and commercial applications (shelving, display cabinets, vending machines, etc.). All luminaires are fitted with diffuser and switch. In addition to versions with standard wiring, the range includes versions with electronic, too. Body and cover: cold-pressed 5/10 mm sheet steel stove enamelled with white or black epoxy-polyester powder paint following phosphate bonderisation. The cover snap fits into the body. Diffuser: impact resistant polycarbonate with clear finish and internal prismatic reeding. Click fits into base. Lampholder, end caps and end cap covers: impact resistant polycarbonate. End caps are pressure-fit in sheet metal body; lampholder and end cap covers clip-fit on the end caps to ensure IP 40. Starter: housed in the luminaire. Control gear and electric circuit: 230V 50Hz, wires with silicon sleeves. All luminaires are fitted with a switch and a terminal block with 2.5mm2 clamping screws. Cable entry: through hole in body with grommet or push through perforations in end caps. The luminaires are supplied complete with /33 COOL WHITE 4000K fluorescent lamps. H A D L Dimensions (mm) A D Type L H Type STY 108 336 37 STY 113 563 37 320 54 550 54 STYLO STY 115 485 STY 118 637 37 330 64 37 475 64 STY 130 942 37 500 64 STY 136 1246 37 800 64 STY 158 1546 37 800 64 Electronic STYLO Electronic version features the following advantages: • Instant lamp starting. • Energy saving up to 20% compared to the standard one, thanks to the lower installed power. • Lower heat emission. • Fittings are power factor corrected (no extra expense for correction parts). • No light flicker or stroboscopic effect, thereby enhancing eyes comfort. • No magnetic fields. • Silent operation. N° and Lamp Type Class: I 230V 50Hz 40 Pack Qty. Box Pallet Product Code IP 40 CEI 34.21 / EN 60598-1 STY 108 WH L 1 x F8 T5 0,70 6/1 1 x F8 T5 0,70 6/1 1044 1044 7004265 STY 108 BK L STY 113 WH L 1 x F13 T5 0,90 6/1 720 7004267 STY 113 BK L 1 x F13 T5 0,90 6/1 720 7004268 STY 115 WH L 1 x F15 T8 1,10 6/1 540 7004269 STY 115 BK L 1 x F15 T8 1,10 6/1 540 7004270 STY 118 WH L 1 x F18 T8 1,30 6/1 540 7004271 STY 118 BK L 1 x F18 T8 1,30 6/1 540 7004272 STY 130 WH L 1 x F30 T8 1,60 6/1 270 7004273 STY 130 BK L 1 x F30 T8 1,60 6/1 270 7004274 STY 136 WH L 1 x F36 T8 1,90 6/1 270 7004275 STY 136 BK L 1 x F36 T8 1,90 6/1 270 7004276 STY 158 WH L 1 x F58 T8 2,60 6/1 270 7004277 STY 158 BK L 1 x F58 T8 2,60 6/1 270 7004278 7004266 L = without power factor correction - Complete with lamp - WH = white BK = black Type N° and Lamp Type Electronic STYLO Weight (kg) Class: I 230V 50Hz Pack Qty. Box Pallet Product Code IP 40 CEI 34.21 / EN 60598-1 STY 118 EB WH 1 x F18 T8 1,10 6/1 540 37394 STY 130 EB WH 1 x F30 T8 1,40 6/1 270 37395 STY 136 EB WH 1 x F36 T8 1,50 6/1 270 37396 STY 158 EB WH 1 x F58 T8 2,10 6/1 270 37397 Complete with lamp - WH = white g GE Lighting Weight (kg) EUROSTYLO POLYLUX XL Enhanced colour rendering Fluorescent luminaire family of reduced section, particularly suitable for both domestic and general lighting (shelves, shop-windows, automatic distributors, etc.). Available range in 7 versions as for length and power. Body and cover: 5/10 mm thick, cold-profiled, previously phosphated pressed sheet steel with black or white stoved epoxy-polyester powder paint finish. The cover is attached to the body with a lock. Diffuser: opal polycarbonate. Clip-fits on body. Lampholder, end caps and end cap covers: polycarbonate. End caps are pressure-fit in sheet metal body; lampholder and end cap covers clip-fit on the end caps to ensure IP 40. Starter: housed in the luminaire. Control gear and electric circuit: 230V 50Hz, wires with silicon sleeves. All luminaires are fitted with a switch and a terminal block with 2,5mm2 clamping screws. Cable entry: through special hole in body with grommet or push-through perforations in end caps. The luminaires are supplied complete with long-life, enhanced colour rendering POLYLUX-XL fluorescent lamps. H A D L Domensions (mm) A D Type L H Type EST 108 336 37 EST 113 563 37 320 54 550 54 EUROSTYLO EST 115 485 EST 118 637 37 330 64 37 475 64 EST 130 942 37 500 64 EST 136 1246 37 800 64 EST 158 1546 37 800 64 N° and Lamp Type Weight (kg) Class: I 230V 50Hz Pack Qty. Box Pallet Product Code IP 40 CEI 34.21 / EN 60598-1 EST 108 WH L 1 x F8 T5 0,70 6/1 1 x F8 T5 0,70 6/1 1044 1044 7002975 EST 108 BK L EST 113 WH L 1 x F13 T5 0,90 6/1 720 7002977 EST 113 BK L 1 x F13 T5 0,90 6/1 720 7002978 EST 115 WH L 1 x F15 T8 1,10 6/1 540 7002979 EST 115 BK L 1 x F15 T8 1,10 6/1 540 7002980 EST 118 WH L 1 x F18 T8 1,30 6/1 540 7002981 EST 118 BK L 1 x F18 T8 1,30 6/1 540 7002982 EST 130 WH L 1 x F30 T8 1,60 6/1 270 7002983 EST 130 BK L 1 x F30 T8 1,60 6/1 270 7002984 EST 136 WH L 1 x F36 T8 1,90 6/1 270 7002985 EST 136 BK L 1 x F36 T8 1,90 6/1 270 7002986 EST 158 WH L 1 x F58 T8 2,60 6/1 270 7002987 EST 158 BK L 1 x F58 T8 2,60 6/1 270 7002988 7002976 L = without power factor correction - Complete with lamp - WH = white BK = black Electronic EUROSTYLO Electronic version features the following advantages: • Instant lamp starting. • Energy saving up to 20% compared to the standard one, thanks to the lower installed power. • Lower heat emission. • Fittings are power factor corrected (no extra expense for correction parts). • No light flicker or stroboscopic effect, thereby enhancing eyes comfort. • No magnetic fields. • Silent operation. Type N° and Lamp Type Electronic EUROSTYLO Weight (kg) Class: I 230V 50Hz Pack Qty. Box Pallet Product Code IP 40 CEI 34.21 / EN 60598-1 EST 118 EB WH 1 x F18 T8 1,10 6/1 540 38446 EST 130 EB WH 1 x F30 T8 1,40 6/1 270 38447 EST 136 EB WH 1 x F36 T8 1,70 6/1 270 38448 EST 158 EB WH 1 x F58 T8 2,40 6/1 270 38449 Complete with lamp - WH = white g GE Lighting 41 Photometric data 5500/236/5 5500/418/5 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.000 DLOR 56 0.588 87 96 LOR 0.588 100 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° 58 C 180° SPACING - HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 1.63 ULOR SHR MAX TR 180.0° 0.0° 90.0° 270.0° 1.91 γ° 150 180 105 90 75 75 150 225 60 300 cd/klm 30 0.564 LOR 87 96 98 0.572 57 SHR NOM 1.50 SHR MAX 1.63 SHR MAX TR 1.90 270° UTILISATION FACTOR – UF (Floor) 135 56 DLOR SPACING - HEIGHT RATIO 0° 270° 120 CIE FLUX CODE 180° 0.008 0 15 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.428 0.394 0.369 0.420 0.390 0.367 0.412 0.386 0.365 0.442 0.404 0.375 0.431 0.397 0.371 0.10 0.10 0.20 0.20 UTILISATION FACTOR – UF (Floor) γ° 1.50 0.488 0.459 0.436 0.478 0.453 0.433 0.469 0.447 0.429 0.509 0.474 0.448 0.494 0.464 0.440 ROOM INDEX 2.00 3.00 0.519 0.554 0.495 0.535 0.474 0.518 0.509 0.542 0.488 0.525 0.469 0.511 0.499 0.531 0.481 0.517 0.465 0.505 0.545 0.586 0.515 0.561 0.490 0.540 0.527 0.565 0.502 0.544 0.480 0.527 4.00 0.572 0.556 0.542 0.559 0.546 0.534 0.548 0.537 0.527 0.608 0.587 0.569 0.585 0.568 0.553 5.00 0.583 0.570 0.558 0.571 0.560 0.549 0.559 0.550 0.541 0.622 0.605 0.589 0.597 0.583 0.570 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.417 0.385 0.360 0.408 0.380 0.357 0.400 0.375 0.355 0.430 0.393 0.366 0.419 0.386 0.361 0.10 0.10 0.20 0.20 1.50 0.474 0.446 0.424 0.463 0.440 0.420 0.453 0.433 0.415 0.494 0.461 0.435 0.478 0.450 0.428 ROOM INDEX 2.00 3.00 0.504 0.537 0.480 0.518 0.461 0.502 0.492 0.524 0.472 0.508 0.455 0.495 0.482 0.513 0.464 0.499 0.449 0.487 0.529 0.568 0.500 0.544 0.476 0.524 0.510 0.546 0.486 0.527 0.465 0.510 4.00 0.554 0.539 0.525 0.541 0.528 0.517 0.528 0.518 0.508 0.589 0.569 0.552 0.565 0.549 0.535 5.00 0.565 0.552 0.540 0.551 0.541 0.531 0.539 0.530 0.521 0.602 0.586 0.571 0.577 0.563 0.551 5500/236/6 5500/418/6 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.000 DLOR 61 0.717 91 98 LOR 0.717 100 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° 71 C 180° SPACING - HEIGHT RATIO 0° SHR NOM 1.25 SHR MAX 1.40 ULOR SHR MAX TR 180.0° 0.0° 90.0° 270.0° 1.56 SHR NOM 270° UTILISATION FACTOR – UF (Floor) γ° 135 150 180 105 90 100 75 200 300 60 400 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.530 0.490 0.459 0.520 0.485 0.457 0.511 0.480 0.455 0.547 0.501 0.467 0.534 0.493 0.462 0.10 0.10 0.20 0.20 1.50 0.602 0.569 0.542 0.591 0.562 0.538 0.580 0.554 0.533 0.628 0.588 0.556 0.610 0.575 0.547 ROOM INDEX 2.00 3.00 0.641 0.682 0.612 0.660 0.589 0.641 0.628 0.668 0.604 0.649 0.583 0.633 0.616 0.655 0.595 0.640 0.577 0.625 0.673 0.722 0.637 0.693 0.608 0.669 0.651 0.696 0.621 0.673 0.596 0.652 5.00 0.717 0.702 0.688 0.701 0.689 0.677 0.688 0.677 0.667 0.764 0.744 0.726 0.734 0.718 0.704 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 0.0° 90.0° 270.0° 135 100 75 200 300 60 400 cd/klm CIE FLUX CODE 0.000 DLOR 55 0.655 90 97 LOR 0.655 SHR NOM 135 150 180 75 150 225 60 300 cd/klm 100 1.50 SHR MAX 1.59 ULOR 90° 65 SHR MAX TR 180.0° 0.0° 90.0° 270.0° 2.32 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.477 0.440 0.411 0.468 0.435 0.409 0.460 0.430 0.407 0.493 0.450 0.418 0.480 0.443 0.414 0.10 0.10 0.20 0.20 1.50 0.547 0.516 0.491 0.536 0.509 0.487 0.526 0.502 0.483 0.570 0.533 0.503 0.553 0.521 0.495 ROOM INDEX 2.00 3.00 0.583 0.621 0.556 0.600 0.534 0.582 0.571 0.608 0.548 0.590 0.529 0.575 0.560 0.596 0.540 0.581 0.523 0.568 0.611 0.657 0.579 0.630 0.552 0.608 0.592 0.633 0.564 0.611 0.541 0.592 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 5.00 0.653 0.639 0.626 0.639 0.627 0.616 0.626 0.616 0.607 0.696 0.677 0.661 0.669 0.653 0.640 1.31 SHR MAX TR 1.55 1.00 0.454 0.423 0.399 0.445 0.418 0.396 0.437 0.413 0.394 0.469 0.433 0.406 0.457 0.425 0.401 0.10 0.10 0.20 0.20 1.50 0.510 0.484 0.463 0.499 0.477 0.458 0.489 0.470 0.453 0.532 0.499 0.474 0.515 0.488 0.466 ROOM INDEX 2.00 3.00 0.539 0.571 0.517 0.554 0.498 0.539 0.528 0.558 0.509 0.543 0.492 0.531 0.517 0.547 0.500 0.534 0.486 0.523 0.566 0.604 0.538 0.581 0.514 0.562 0.547 0.581 0.523 0.563 0.503 0.547 4.00 0.588 0.574 0.561 0.574 0.562 0.552 0.562 0.552 0.543 0.624 0.606 0.589 0.600 0.585 0.571 5.00 0.598 0.586 0.575 0.584 0.574 0.565 0.571 0.563 0.555 0.637 0.621 0.607 0.611 0.598 0.587 0.008 60 DLOR 0.583 LOR 0.591 92 98 98 59 SHR NOM 1.75 SHR MAX 1.95 SHR MAX TR 2.11 UTILISATION FACTOR – UF (Floor) 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 CIE FLUX CODE 0.000 DLOR 65 0.654 96 99 LOR 0.654 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.471 0.444 0.424 0.463 0.440 0.421 0.456 0.435 0.418 0.487 0.455 0.430 0.475 0.447 0.426 0.10 0.10 0.20 0.20 100 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° SPACING - HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 1.59 ULOR 65 C 180° SHR MAX TR 180.0° 0.0° 90.0° 270.0° 2.01 1.50 0.519 0.496 0.478 0.509 0.490 0.473 0.500 0.483 0.469 0.541 0.513 0.490 0.526 0.502 0.482 ROOM INDEX 2.00 3.00 0.545 0.572 0.526 0.557 0.509 0.544 0.534 0.560 0.518 0.547 0.503 0.536 0.524 0.548 0.510 0.537 0.497 0.528 0.572 0.605 0.547 0.584 0.526 0.567 0.554 0.583 0.533 0.566 0.515 0.552 4.00 0.586 0.574 0.563 0.573 0.563 0.553 0.561 0.553 0.545 0.623 0.606 0.591 0.599 0.585 0.573 5.00 0.595 0.584 0.574 0.581 0.573 0.565 0.569 0.562 0.555 0.634 0.620 0.607 0.608 0.597 0.586 γ° 135 150 180 105 90 75 75 150 225 60 300 cd/klm 15 0 42 CIE FLUX CODE 0.000 62 DLOR 0.630 LOR 0.630 96 98 100 63 180° SPACING - HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 1.59 SHR MAX TR 2.01 270° UTILISATION FACTOR – UF (Floor) g GE Lighting 59 SPACING - HEIGHT RATIO 0° 270° 30 98 5500/236/16 POLAR DIAGRAM OF OUTPUT 120 CIE FLUX CODE 180° γ° 4.00 0.640 0.624 0.609 0.627 0.613 0.600 0.614 0.603 0.592 0.680 0.658 0.639 0.655 0.637 0.621 5500/418/16 270.0° 98 270° 75 90.0° 92 Floor 0.10 CIE FLUX CODE SPACING - HEIGHT RATIO 0° 90 0.0° 0 15 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 (cd/1000 lm) C γ° C 0.599 SHR MAX NORMAL EFFICIENCY 180° 105 180.0° 1.25 POLAR DIAGRAM OF OUTPUT UTILISATION FACTOR – UF (Floor) 30 180 90 270° 120 150 105 30 LOR 5500/236/12 5500/418/12 180.0° 120 0.591 UTILISATION FACTOR – UF (Floor) γ° 4.00 0.704 0.686 0.670 0.689 0.674 0.660 0.675 0.663 0.652 0.747 0.724 0.704 0.720 0.701 0.684 65 DLOR SPACING - HEIGHT RATIO 0° 270° 120 CIE FLUX CODE 180° 0.008 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 1.00 0.522 0.492 0.469 0.514 0.487 0.466 0.507 0.483 0.464 0.539 0.503 0.476 0.527 0.496 0.472 1.50 0.580 0.555 0.535 0.571 0.549 0.531 0.561 0.543 0.527 0.605 0.574 0.549 0.589 0.562 0.541 ROOM INDEX 2.00 3.00 0.609 0.639 0.588 0.623 0.571 0.609 0.598 0.627 0.581 0.613 0.565 0.602 0.588 0.616 0.573 0.605 0.560 0.594 0.639 0.676 0.612 0.654 0.590 0.635 0.620 0.653 0.598 0.635 0.578 0.620 UTILISATION FACTOR – UF (Floor) γ° 4.00 0.654 0.641 0.630 0.641 0.631 0.621 0.630 0.621 0.613 0.695 0.677 0.661 0.670 0.656 0.643 5.00 0.664 0.653 0.643 0.651 0.642 0.633 0.639 0.631 0.624 0.708 0.693 0.679 0.681 0.669 0.658 120 135 150 180 105 90 100 75 200 300 60 400 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 1.00 0.551 0.530 0.513 0.545 0.526 0.511 0.539 0.522 0.508 0.569 0.542 0.521 0.559 0.535 0.517 1.50 0.587 0.569 0.554 0.579 0.563 0.550 0.571 0.557 0.546 0.613 0.588 0.568 0.598 0.577 0.560 ROOM INDEX 2.00 3.00 0.609 0.631 0.594 0.619 0.581 0.608 0.600 0.620 0.587 0.609 0.575 0.601 0.591 0.610 0.580 0.601 0.570 0.593 0.639 0.667 0.618 0.649 0.600 0.634 0.622 0.645 0.604 0.631 0.589 0.619 4.00 0.642 0.632 0.623 0.630 0.622 0.614 0.619 0.612 0.606 0.682 0.667 0.654 0.658 0.646 0.636 5.00 0.648 0.640 0.632 0.636 0.630 0.623 0.625 0.619 0.614 0.691 0.679 0.668 0.666 0.656 0.647 Photometric data 5502 / 234 / C POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.000 52 DLOR 0.454 LOR 0.454 84 97 100 45 1.58 SHR MAX TR 1.79 180° SPACING - HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 270° UTILISATION FACTOR – UF (Floor) γ° 120 135 150 180 105 90 40 75 80 120 60 160 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.313 0.286 0.265 0.307 0.283 0.264 0.301 0.279 0.262 0.323 0.293 0.270 0.315 0.288 0.267 0.10 0.10 0.20 0.20 1.50 0.362 0.339 0.321 0.354 0.334 0.318 0.347 0.330 0.315 0.377 0.350 0.329 0.366 0.342 0.324 ROOM INDEX 2.00 3.00 0.388 0.416 0.368 0.401 0.352 0.387 0.379 0.407 0.363 0.394 0.348 0.382 0.372 0.398 0.357 0.387 0.344 0.377 0.407 0.440 0.383 0.420 0.363 0.404 0.393 0.424 0.373 0.408 0.356 0.394 4.00 0.430 0.418 0.407 0.421 0.411 0.401 0.412 0.404 0.396 0.457 0.441 0.428 0.440 0.427 0.416 5.00 0.440 0.429 0.420 0.430 0.422 0.413 0.421 0.414 0.407 0.469 0.455 0.443 0.450 0.439 0.429 5502 / 234 / L POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.000 43 DLOR 0.404 LOR 0.404 75 94 100 40 1.65 SHR MAX TR 1.98 180° SPACING - HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 270° UTILISATION FACTOR – UF (Floor) γ° 120 135 150 180 105 90 30 75 60 90 60 120 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 1.00 0.250 0.222 0.201 0.244 0.219 0.199 0.238 0.216 0.198 0.258 0.227 0.204 0.250 0.223 0.202 0.10 0.10 0.20 0.20 1.50 0.298 0.273 0.254 0.291 0.269 0.251 0.283 0.265 0.249 0.311 0.282 0.260 0.300 0.276 0.256 ROOM INDEX 2.00 3.00 0.324 0.355 0.303 0.338 0.285 0.323 0.316 0.346 0.298 0.332 0.282 0.319 0.309 0.338 0.293 0.326 0.279 0.315 0.340 0.375 0.315 0.355 0.295 0.337 0.328 0.360 0.307 0.344 0.289 0.329 4.00 0.371 0.357 0.345 0.362 0.350 0.340 0.354 0.344 0.335 0.394 0.377 0.362 0.378 0.364 0.352 5.00 0.381 0.370 0.359 0.372 0.363 0.353 0.364 0.356 0.348 0.406 0.392 0.379 0.389 0.378 0.367 NUA 136 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 180° 0.293 44 DLOR 0.523 LOR 0.816 70 87 64 81 SPACING - HEIGHT RATIO 0° SHR NOM 1.50 SHR MAX 1.70 SHR MAX TR 2.04 270° UTILISATION FACTOR – UF (Floor) γ° 135 150 165 180 120 225 150 105 75 90 75 75 150 225 60 cd/klm 45 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.395 0.341 0.303 0.358 0.314 0.281 0.323 0.287 0.260 0.406 0.347 0.306 0.366 0.318 0.283 1.00 0.451 0.398 0.357 0.406 0.362 0.328 0.364 0.329 0.301 0.466 0.407 0.362 0.417 0.369 0.332 1.50 0.531 0.482 0.443 0.476 0.437 0.405 0.424 0.393 0.368 0.554 0.498 0.455 0.492 0.448 0.412 ROOM INDEX 2.00 3.00 0.578 0.632 0.534 0.596 0.497 0.564 0.517 0.565 0.483 0.537 0.453 0.512 0.460 0.513 0.433 0.480 0.409 0.460 0.606 0.668 0.556 0.626 0.514 0.589 0.536 0.589 0.497 0.556 0.463 0.527 4.00 0.662 0.632 0.605 0.592 0.568 0.547 0.527 0.508 0.491 0.704 0.667 0.635 0.619 0.591 0.566 5.00 0.682 0.656 0.631 0.610 0.590 0.570 0.543 0.526 0.511 0.727 0.695 0.667 0.639 0.615 0.592 NUA 236 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 180° 0.141 44 DLOR 0.591 LOR 0.733 73 88 80 73 SPACING - HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 1.79 SHR MAX TR 2.22 270° UTILISATION FACTOR – UF (Floor) γ° 120 135 150 180 105 90 40 75 80 120 60 160 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.384 0.335 0.299 0.362 0.319 0.288 0.341 0.304 0.276 0.394 0.341 0.302 0.370 0.324 0.290 1.00 0.437 0.387 0.349 0.410 0.368 0.335 0.384 0.349 0.320 0.451 0.396 0.355 0.420 0.374 0.339 1.50 0.511 0.467 0.431 0.479 0.441 0.410 0.447 0.416 0.390 0.533 0.482 0.442 0.494 0.452 0.417 ROOM INDEX 2.00 3.00 0.554 0.603 0.513 0.570 0.480 0.541 0.518 0.563 0.484 0.536 0.456 0.512 0.483 0.531 0.456 0.503 0.432 0.483 0.581 0.638 0.534 0.598 0.496 0.564 0.536 0.587 0.498 0.555 0.466 0.527 4.00 0.631 0.602 0.577 0.589 0.566 0.545 0.550 0.531 0.514 0.670 0.636 0.606 0.615 0.588 0.564 5.00 0.649 0.624 0.602 0.606 0.586 0.567 0.566 0.550 0.534 0.692 0.662 0.635 0.634 0.611 0.589 g GE Lighting 43 MULTILITE System 8000 MULTILITE System 8000 MULTILITE System 8000 is an extremely compact single and twin lamp lighting system, specially created to facilitate the design of modern interior lighting schemes. Made of aluminium, modules and joints all have the same section, bringing continuity to the entire installation. The modular design of the system and wide variety of light sources available offer an infinite variety of application solutions that are ideal for meeting the varied demands of offices, banks, shops, libraries, etc. The new connecting module Cat. No. 3179 can connect System 8000 and System 3000 elements while the new louvre (Cat. No. 3004) of System 3000 is ideal for work environments with video display terminals. Cat. No. 8190 Cat. No. 8189 Cat. No. 3179 Cat. No. 8187 Cat. No. 8171 Cat. No. 3179 Cat. No. 8170 Cat. No. 6169 Cat. No. 8185 Cat. No. 6169 Cat. No. 8172 Cat. No. 8176 Cat. No. 8186 Cat. No. 8184 Cat. No. 8174 Cat. No. 8180 Cat. No. 8188 Cat. No. 8175 Cat. No. 8178 Cat. No. 8173 WHITE: RED: BLACK: g GE Lighting 44 RAL 3000 RAL 9005 (code WH) (code RD) (code BK) MULTILITE System 8000 Technical Characteristics Modules: extruded aluminium with stoved painted finish in 3 standard colours. End cap and joints: die-cast aluminium, complete with internal connectors, with stoved painted finish in 3 standard colours. Internal reflectors: polished aluminium with polyester protection film. Diffusers: methacrylate with prismatic internal reeding. Louvre: polycarbonate. Compliance with standards: IEC 34.21- EN 60598-1. Type Length (mm) Weight (kg) Pack Qty. Product Code Wired module with power factor correction for one T8 fluorescent lamp. Cat. No. 8001 Class: I 230V 50Hz IP 20 IP 40 with diffuser Cat. No. 8151 90° 8001.136 180° C 180.0° 0.0° 90.0° 270.0° γ° 180 0° 270° 150 135 8001 118 WH 1100 2,20 1 38083 8001 118 RD 1100 2,20 1 38084 8001 118 BK 1100 2,20 1 38085 8001 136 WH 1650 2,90 1 38086 8001 136 RD 1650 2,90 1 38087 8001 136 BK 1650 2,90 1 38088 8001 158 WH 2200 4,20 1 38089 8001 158 RD 2200 4,20 1 38090 8001 158 BK 2200 4,20 1 38091 120 105 105 90 90 50 75 75 100 150 60 40 60 200 cd/klm 30 120 15 ULOR 4,6% 0 15 DLOR 85,0% 30 LOR 89,6% Without lamp. Wired module with power factor correction for twoT8 fluorescent lamps. Cat. No. 8002 8002.236 180° C γ° 180.0° 0.0° 90.0° 270.0° 180 0° 270° 150 135 105 90 90 75 75 75 150 225 60 40 60 300 cd/klm 30 ULOR 4,3% 15 0 15 DLOR 84,4% IP 20 IP 40 with diffuser Cat. No. 8151 8002 218 WH 1100 2,80 1 38093 8002 218 RD 1100 2,80 1 38094 8002 218 BK 1100 2,80 1 38095 8002 236 WH 1650 3,50 1 38096 8002 236 RD 1650 3,50 1 38097 8002 236 BK 1650 3,50 1 38098 8002 258 WH 2200 6,00 1 38099 8002 258 RD 2200 6,00 1 38101 8002 258 BK 2200 6,00 1 38102 120 105 120 Class: I 230V 50Hz 90° 30 LOR 88,7% Without lamp. Wired module with power factor correction and electronic supply unit for T8 fluorescent lamps. Cat. No. 8025 Electronic Class: I IP 20 230V 50Hz 8025 136 WH EB 1650 2,65 1 38022 8025 136 RD EB 1650 2,65 1 38023 8025 136 BK EB 1650 2,65 1 38024 8025 158 WH EB 2200 3,70 1 38027 8025 158 RD EB 2200 3,70 1 38029 8025 158 BK EB 2200 3,70 1 38030 8025 236 WH EB 1650 2,80 1 38036 8025 236 RD EB 1650 2,80 1 38037 8025 236 BK EB 1650 2,80 1 38038 8025 258 WH EB 2200 4,80 1 38041 8025 258 RD EB 2200 4,80 1 38042 8025 258 BK EB 2200 4,80 1 38043 Without lamp. WH = white RD = red BK = black g GE Lighting 45 MULTILITE System 8000 Length (mm) Type Weight (kg) Pack Qty. Product Code Emergency lighting module for fluorescent lamp with EES unit for permanent illumination (duration 1 h), Cat. No. 8030 emergency Class: I 230V 50Hz 40 120 IP 20 IP 40 with diffuser Cat. No. 8151 8030 218 WH EES 1100 3,20 1 38112 8030 218 RD EES 1100 3,20 1 38113 8030 218 BK EES 1100 3,20 1 38116 8030 236 WH EES 1650 4,00 1 38117 8030 236 RD EES 1650 4,00 1 38118 8030 236 BK EES 1650 4,00 1 38119 8030 258 WH EES 2200 6,50 1 38120 8030 258 RD EES 2200 6,50 1 38122 8030 258 BK EES 2200 6,50 1 38125 Without lamp. Module for 3 fixed Ø 50 mm dichroic mirror 35W 12V halogen lamps. Complete with die-cast aluminium ring nuts and 230V 50Hz electromagnetic transformer with heat protection. Cat. No. 8015 Class: I IP 20 230V 50Hz 40 120 8015 WH 1100 2,20 1 38103 8015 RD 1100 2,20 1 38104 8015 BK 1100 2,20 1 38105 Without lamp. Module with 3 swivelling Ø 35 mm dichroic mirror 35W 12V halogen lamps. With 230V 50Hz electromagnetic transformer with heat protection. Cat. No. 8016 Class: I IP 20 230V 50Hz 40 120 8016 WH 1100 2,20 1 38106 8016 RD 1100 2,20 1 38107 8016 BK 1100 2,20 1 38108 Without lamp. Module with 230V electrified track for Guzzini, Erco, Staff, Hoffmeister, Nokia spotlights with adapters (without spotlights and lamps). Cat. No. 8018 Class: I 230V 50Hz 40 120 8018 WH 1100 3,80 1 38126 8018 RD 1100 3,80 1 38127 8018 BK 1100 3,80 1 38128 Module for R7s cap linear halogen lamp. Complete with protective front cover glass Cat. No. 8166. Cat. No. 8022 Class: I 230V 50Hz 40 120 8022 WH 550 1,00 1 38109 8022 RD 550 1,00 1 38110 8022 BK 550 1,00 1 38111 Without lamp. g GE Lighting 46 WH = white RD = rred BK = black MULTILITE System 8000 Length (mm) Type Weight (kg) Pack Qty. Product Code Structural compensation module (can be opened for inspection). Cat. No. 8100 40 120 8100 275 WH 275 0,40 1 38129 8100 275 RD 275 0,40 1 38130 8100 275 BK 275 0,40 1 38131 8100 550 WH 550 0,80 1 38132 8100 550 RD 550 0,80 1 38133 8100 550 BK 550 0,80 1 38134 8100 1100 WH 1100 1,50 1 38135 8100 1100 RD 1100 1,50 1 38136 8100 1100 BK 1100 1,50 1 38137 8100 1650 WH 1650 2,20 1 38138 8100 1650 RD 1650 2,20 1 38139 8100 1650 BK 1650 2,20 1 38140 8100 2200 WH 2200 3,00 1 38141 8100 2200 RD 2200 3,00 1 38142 8100 2200 BK 2200 3,00 1 38143 Module with 1W/4 OHM loudspeaker. Cat. No. 8140 40 120 8140 WH 550 0,90 1 38144 8140 RD 550 0,90 1 38145 8140 BK 550 0,90 1 38146 Module for switches and plugs box. Cat. No. 8141 40 120 WH = white RD = rred BK = black 8141 WH 550 0,80 1 38147 8141 RD 550 0,80 1 38150 8141 BK 550 0,80 1 38149 g GE Lighting 47 MULTILITE System 8000 Type With Pack Product Luminaire Qty. Code Type Clip-fit polycarbonate louvre with metal finish. 40 120 12/1 38151 8149 4 1-2 x 36 7/1 38152 8149 5 1-2 x 36 5/1 38153 160 Cat. No. 8150 40 120 1-2 x 18 38158 8150 4 1-2 x 36 7/1 38160 8150 5 1-2 x 36 5/1 38161 160 Clip-fit metacrylate diffuser, Protection level increase from IP 20 to IP 40. 120 10/1 38180 8174 RD 10/1 38186 8174 BK 10/1 38188 8175 WH 7/1 38189 8175 RD 7/1 38190 8175 BK 7/1 38191 90° ÷ 270° adjustable horizontal joint complete with internal connectors. 140 Cat. No. 8151 40 8174 WH Cat. No. 8175 160 12/1 Code “X” joint complete with internal connectors. Clip-fit opal polycarbonate louvre. 8150 2 Product Qty. Cat. No. 8174 140 1-2 x 18 Pack “T” joint complete with internal connectors. Cat. No. 8149 8149 2 With Luminaire Cat. No. 8176 8151 2 1-2 x 18 4/1 38162 8176 WH 7/1 38192 8151 4 1-2 x 36 4/1 38163 8176 RD 7/1 38193 8151 5 1-2 x 36 4/1 38164 8176 BK 7/1 38194 90°÷ 270° Adjustable flaps for Cat. No. 8022 - 8300 - 8400. Cat. No. 8165 8165 1 38165 Front cover glass for Cat. No. 8022 - 8300 - 8400. Straight internal connector for connecting modules. Cat. No. 8166 Cat. No. 8178 8166 1 38166 8178 Cat. No. 8170 120 18 Cat. No. 8180 8170 WH 25/1 38167 8170 RD 25/1 38168 8170 BK 25/1 38169 40 215 120 End cap complete with cable entry and internal connectors. 120 25/1 38170 8171 RD 25/1 38171 8171 BK 25/1 38172 360° 40 80 120 40 360° 38198 8180 BK 5/1 38221 8184 WH 12/1 38236 8184 RD 12/1 38237 8184 BK 12/1 38238 End cap complete with internal connectors and wall/ceiling mounting bracket. Cat. No. 8185 Cat. No. 8172 120 38195 5/1 Cat. No. 8184 8171 WH Rotating straight joint with internal connectors. 40 5/1 8180 RD 40 40 18 8180 WH Rotating straight joint complete with end caps with internal connectors and wall/ceiling mounting bracket. Cat. No. 8171 50 38222 90° ÷ 270° adjustable vertical bellows joint complete with end caps and internal connectors. End cap complete with internal connectors. 40 50/1 8172 WH 15/1 38173 8172 RD 15/1 38174 8172 BK 15/1 38175 360° 80 40 32 120 8185 WH 12/1 38223 8185 RD 12/1 38224 8185 BK 12/1 38225 Ø 50 Ceiling suspension set complete with 2m steel cable, mounting pin and ceiling rose. Horizontal 90° joint complete with internal connectors. 2000 Cat. No. 8173 140 g GE Lighting 48 Cat. No. 8186 8173 WH 12/1 38177 8186 WH 40/1 38226 8173 RD 12/1 38178 8186 RD 40/1 38227 8173 BK 12/1 38179 8186 BK 40/1 38228 WH = white RD = rred BK = black MULTILITE System 8000 Type With Pack Product Luminaire Qty. Code Type With Pack Product Luminaire Qty. Code 3 x 1,5 mm 2 power supply cable, which can be extended to 2m. Cat. No. 8190 2000 Ø 40 30 Adjustable static ceiling mounting. 8190 WH 12/1 38081 Cat. No. 8187 8190 RD 12/1 38239 8190 BK 12/1 38082 8187 40/1 38230 Straight joint for connecting System 6000 to System 8000, complete with internal connectors. Cat. No. 6169 360° Ø 40 5 Equaliser for modules. Cat. No. 8188 8188 Ø 75 2000 Ø 60 40 37 100/1 38231 120 6169 WH 10/1 38316 6169 RD 10/1 38317 6169 BK 10/1 38318 Power supply set complete with mounting pin, terminal block, large ceiling rose and 3 x 1,5 mm 2 power supply cable, extending to 2m. Straight joint for connecting System 3000 to System 8000. Cat. No. 8189 Cat. No. 3179 8189 WH 10/1 38233 3179 WH 10/1 38046 8189 RD 10/1 38234 3179 RD 10/1 38048 8189 BK 10/1 38235 3179 BK 10/1 38049 Electrical connection All pre-wired modules feature a four-pole terminal block at both ends suitable for hard wire or flexible cables with a section of up to 2.5 mm2. L1 = module power supply through line. L2 = through line for separate switching only. N = neutral through line. Control gear: 230V 50Hz, heat-resistant 1.5 mm2 cables. Mechanical connection Straight extruded aluminium modules are connected to one another using accessory Cat. No. 8178. WH = white RD = rred BK = black g GE Lighting 49 MULTILITE System 8000 FREE-STANDING – WALL-MOUNTED UPLIGHT FREE-STANDING UPLIGHT Cat. No. 8300 Free-standing uplight luminaires for linear halogen lamp (included) (max. 300W) complete with protective front cover glass Cat. No. 8166 and dimmer. Body: extruded aluminium body with cast iron base, both with a stoved painted finish. Accessories: adjustable flaps Cat. No. 8165. Weight (kg) Type Pack Qty. Product Code 1900 Cat. No. 8300 IP 20 230V 50Hz Ø 50 CEI 34.21 / EN 60598-1 8300 WH 7,00 1 38366 8300 RD 7,00 1 38367 8300 BK 7,00 1 38254 Complete with lamp. WALL-MOUNTED UPLIGHT Cat. No. 8400 Wall-mounted uplight luminaires for linear halogen lamp (included) (max. 300W) complete with protective front cover glass Cat. No. 8166. Body: extruded aluminium with stoved paint finish. Accessories: adjustable flaps Cat. No. 8165. 40 250 120 Cat. No. 8400 IP 20 230V 50Hz 0,60 1 38368 8400 RD 0,60 1 38369 8400 BK 0,60 1 38370 Complete with lamp. g GE Lighting 50 CEI 34.21 / EN 60598-1 8400 WH WH = white RD = red BK = black Photometric data 8002.236 8001.136 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° C 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 0.046 DLOR 37 0.850 67 87 LOR 0.896 94 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 90° 89 C 180° SPACING – HEIGHT RATIO 0° SHR NOM 1.75 SHR MAX 1.85 ULOR SHR MAX TR 180.0° 0.0° 90.0° 270.0° 2.39 γ° 150 180 105 90 50 75 100 150 60 200 cd/klm 30 0 15 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.452 0.384 0.334 0.435 0.375 0.329 0.420 0.366 0.324 0.464 0.391 0.338 0.445 0.380 0.332 1.00 0.520 0.451 0.398 0.500 0.439 0.392 0.481 0.427 0.385 0.537 0.462 0.405 0.513 0.447 0.396 1.50 0.623 0.561 0.510 0.599 0.545 0.500 0.576 0.529 0.489 0.651 0.579 0.524 0.619 0.558 0.509 ROOM INDEX 2.00 3.00 0.683 0.752 0.626 0.705 0.579 0.664 0.656 0.723 0.607 0.683 0.566 0.648 0.631 0.698 0.589 0.662 0.553 0.631 0.716 0.795 0.651 0.740 0.598 0.693 0.680 0.753 0.625 0.707 0.579 0.667 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 0.0° 90.0° 270.0° CIE FLUX CODE 5.00 0.816 0.782 0.750 0.786 0.757 0.730 0.758 0.733 0.710 0.870 0.829 0.792 0.823 0.788 0.758 SHR NOM SHR NOM 150 180 90 40 75 80 120 60 160 cd/klm 0.032 DLOR 40 0.542 71 89 LOR 0.573 94 1.75 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° 90.0° 270.0° 75 150 225 60 300 cd/klm 30 15 CIE FLUX CODE 1.83 ULOR 90° SHR MAX TR 2.41 180.0° 0.0° SHR NOM 150 180 90 50 75 100 150 60 200 cd/klm 0.75 0.301 0.259 0.228 0.290 0.253 0.225 0.280 0.247 0.221 0.309 0.263 0.230 0.296 0.256 0.226 1.00 0.344 0.302 0.270 0.331 0.294 0.265 0.319 0.286 0.260 0.356 0.309 0.274 0.340 0.299 0.268 1.50 0.410 0.372 0.342 0.395 0.362 0.335 0.380 0.352 0.328 0.428 0.385 0.351 0.408 0.371 0.341 ROOM INDEX 2.00 3.00 0.448 0.491 0.414 0.463 0.385 0.439 0.431 0.473 0.402 0.449 0.377 0.428 0.415 0.457 0.390 0.436 0.368 0.418 0.470 0.519 0.431 0.486 0.398 0.458 0.446 0.492 0.414 0.465 0.386 0.441 4.00 0.515 0.492 0.471 0.496 0.476 0.458 0.478 0.462 0.447 0.547 0.519 0.495 0.518 0.495 0.475 5.00 0.530 0.510 0.492 0.511 0.494 0.479 0.493 0.479 0.466 0.565 0.541 0.520 0.535 0.515 0.497 0.043 DLOR 39 0.692 70 89 LOR 0.735 94 90.0° 270.0° 1.75 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE ULOR 90° CIE FLUX CODE 120 SHR NOM 135 150 75 75 150 225 60 300 cd/klm 30 0.10 0.10 0.20 0.20 0.032 48 1.50 0.75 0.497 0.436 0.391 0.481 0.427 0.386 0.467 0.419 0.381 0.510 0.443 0.395 0.492 0.433 0.389 1.00 0.562 0.501 0.453 0.543 0.489 0.447 0.526 0.478 0.440 0.580 0.512 0.461 0.557 0.498 0.452 1.50 0.659 0.604 0.560 0.636 0.589 0.550 0.615 0.574 0.540 0.687 0.624 0.574 0.657 0.603 0.560 ROOM INDEX 2.00 3.00 0.713 0.776 0.665 0.737 0.624 0.702 0.689 0.750 0.647 0.716 0.611 0.686 0.665 0.726 0.630 0.696 0.599 0.670 0.748 0.821 0.692 0.774 0.644 0.733 0.714 0.780 0.666 0.741 0.625 0.707 4.00 0.811 0.778 0.748 0.783 0.755 0.730 0.757 0.734 0.712 0.861 0.821 0.786 0.818 0.785 0.756 5.00 0.833 0.805 0.779 0.805 0.781 0.759 0.778 0.758 0.740 0.888 0.854 0.822 0.842 0.814 0.788 DLOR 0.665 LOR 0.697 78 93 95 69 SHR MAX 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 1.85 ULOR 90° SHR MAX TR 2.38 0.75 0.380 0.325 0.286 0.366 0.318 0.281 0.353 0.310 0.277 0.390 0.331 0.289 0.374 0.322 0.283 1.00 0.436 0.381 0.339 0.419 0.370 0.333 0.403 0.360 0.326 0.450 0.390 0.344 0.430 0.377 0.336 1.50 0.520 0.471 0.431 0.500 0.457 0.422 0.481 0.444 0.413 0.543 0.486 0.442 0.516 0.468 0.429 ROOM INDEX 2.00 3.00 0.569 0.625 0.524 0.588 0.487 0.557 0.546 0.601 0.508 0.569 0.475 0.542 0.525 0.579 0.493 0.552 0.464 0.528 0.597 0.661 0.545 0.618 0.503 0.581 0.566 0.625 0.523 0.590 0.487 0.559 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 180° 1.53 SHR MAX TR 1.69 0.75 0.407 0.361 0.328 0.396 0.355 0.325 0.385 0.349 0.321 0.418 0.368 0.331 0.405 0.360 0.327 1.00 0.459 0.413 0.378 0.445 0.404 0.373 0.431 0.396 0.368 0.474 0.423 0.384 0.456 0.411 0.377 1.50 0.534 0.494 0.461 0.517 0.482 0.453 0.501 0.471 0.446 0.557 0.510 0.473 0.533 0.494 0.462 ROOM INDEX 2.00 3.00 0.575 0.622 0.540 0.594 0.510 0.569 0.557 0.602 0.526 0.578 0.500 0.557 0.539 0.584 0.513 0.563 0.491 0.544 0.604 0.658 0.562 0.623 0.527 0.594 0.577 0.627 0.542 0.598 0.512 0.574 4.00 0.648 0.624 0.603 0.626 0.607 0.589 0.607 0.590 0.575 0.688 0.659 0.633 0.655 0.631 0.610 5.00 0.664 0.644 0.625 0.642 0.626 0.610 0.623 0.608 0.595 0.708 0.683 0.660 0.672 0.652 0.634 5.00 0.676 0.649 0.625 0.650 0.629 0.608 0.627 0.608 0.590 0.720 0.689 0.660 0.681 0.655 0.631 120 SHR NOM 135 46 DLOR 0.766 LOR 0.815 75 91 94 81 1.50 SHR MAX 1.55 SHR MAX TR 1.74 UTILISATION FACTOR – UF (Floor) 150 180 105 90 75 75 150 225 60 300 cd/klm 30 0.049 SPACING – HEIGHT RATIO 0° γ° 4.00 0.656 0.625 0.598 0.630 0.605 0.581 0.607 0.586 0.566 0.697 0.660 0.628 0.659 0.629 0.602 SHR NOM 150 0 15 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.462 0.406 0.366 0.447 0.398 0.361 0.433 0.389 0.356 0.474 0.414 0.370 0.457 0.403 0.364 1.00 0.521 0.466 0.423 0.503 0.454 0.417 0.486 0.443 0.410 0.538 0.477 0.430 0.516 0.462 0.422 1.50 0.608 0.560 0.520 0.587 0.545 0.510 0.566 0.530 0.499 0.635 0.578 0.533 0.606 0.558 0.519 ROOM INDEX 2.00 3.00 0.658 0.714 0.614 0.679 0.578 0.648 0.634 0.688 0.597 0.658 0.565 0.632 0.611 0.666 0.580 0.639 0.552 0.616 0.690 0.755 0.639 0.713 0.597 0.676 0.657 0.717 0.614 0.682 0.578 0.651 4.00 0.745 0.715 0.689 0.718 0.693 0.671 0.693 0.672 0.653 0.791 0.755 0.724 0.750 0.721 0.695 5.00 0.765 0.740 0.716 0.737 0.717 0.697 0.712 0.694 0.677 0.815 0.784 0.756 0.772 0.746 0.723 180 90 50 75 100 150 200 cd/klm 15 DLOR 41 0.770 71 89 LOR 0.861 89 POLAR DIAGRAM OF OUTPUT NORMAL EFFICIENCY (cd/1000 lm) CIE FLUX CODE 1.50 SHR MAX 1.67 ULOR 90° 86 SHR MAX TR 2.00 180.0° 0.0° 90.0° 270.0° CIE FLUX CODE 180° 0.058 47 DLOR 0.696 LOR 0.754 76 92 92 75 SPACING – HEIGHT RATIO 0° SHR NOM 1.25 SHR MAX 1.47 SHR MAX TR 1.62 270° 105 60 0.091 UTILISATION FACTOR – UF (Floor) γ° 30 180 90 SPACING – HEIGHT RATIO 0° 135 CIE FLUX CODE 105 C 180° 270° 120 1.67 8002.236 + 8151.4 POLAR DIAGRAM OF OUTPUT 270.0° SHR MAX TR UTILISATION FACTOR – UF (Floor) 73 8001.136 + 8151.4 90.0° 1.53 SPACING – HEIGHT RATIO 0° 270° γ° 0.0° 88 180° γ° SPACING – HEIGHT RATIO 105 C Floor 0.10 CIE FLUX CODE UTILISATION FACTOR – UF (Floor) 180.0° 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 (cd/1000 lm) C 0° 30 95 SHR MAX NORMAL EFFICIENCY 180° 135 1.50 POLAR DIAGRAM OF OUTPUT 270° 120 91 8002.236 + 8150.4 POLAR DIAGRAM OF OUTPUT 0.0° 180 57 8001.136 + 8150.4 C 74 270° 105 180.0° 150 75 UTILISATION FACTOR – UF (Floor) γ° 30 135 90 SPACING – HEIGHT RATIO 0° 135 120 105 C 180° 270° 120 0.888 8002.236 + 8149.4 POLAR DIAGRAM OF OUTPUT C LOR UTILISATION FACTOR – UF (Floor) γ° 4.00 0.790 0.751 0.715 0.761 0.727 0.696 0.733 0.705 0.678 0.840 0.793 0.751 0.795 0.756 0.721 8001.136 + 8149.4 180.0° 0.844 270° UTILISATION FACTOR – UF (Floor) 135 45 DLOR SPACING – HEIGHT RATIO 0° 270° 120 CIE FLUX CODE 180° 0.043 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.451 0.390 0.345 0.431 0.378 0.337 0.413 0.366 0.329 0.463 0.397 0.349 0.441 0.383 0.340 1.00 0.515 0.454 0.407 0.491 0.438 0.396 0.469 0.422 0.385 0.532 0.464 0.413 0.504 0.446 0.401 1.50 0.611 0.556 0.511 0.582 0.535 0.496 0.555 0.515 0.481 0.638 0.574 0.525 0.601 0.548 0.505 ROOM INDEX 2.00 3.00 0.665 0.728 0.616 0.688 0.575 0.653 0.634 0.694 0.592 0.660 0.556 0.630 0.604 0.665 0.569 0.633 0.538 0.608 0.698 0.770 0.641 0.722 0.594 0.681 0.657 0.722 0.609 0.683 0.569 0.649 UTILISATION FACTOR – UF (Floor) γ° 4.00 0.763 0.729 0.699 0.727 0.699 0.673 0.693 0.670 0.648 0.810 0.770 0.734 0.759 0.726 0.697 5.00 0.785 0.756 0.729 0.749 0.725 0.702 0.715 0.694 0.675 0.837 0.802 0.770 0.784 0.755 0.729 120 135 150 180 105 90 75 75 150 225 60 300 cd/klm 30 15 0 REFLECTION FACTOR Ceiling Walls 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 0.30 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.50 0.30 0.10 Floor 0.10 0.10 0.10 0.20 0.20 0.75 0.403 0.349 0.310 0.387 0.340 0.305 0.374 0.331 0.299 0.414 0.355 0.313 0.396 0.345 0.307 1.00 0.471 0.419 0.380 0.453 0.408 0.372 0.436 0.396 0.365 0.487 0.429 0.386 0.465 0.415 0.376 1.50 0.553 0.507 0.469 0.531 0.491 0.458 0.510 0.476 0.447 0.577 0.523 0.481 0.548 0.503 0.466 ROOM INDEX 2.00 3.00 0.600 0.655 0.559 0.621 0.525 0.592 0.576 0.628 0.541 0.600 0.511 0.575 0.553 0.606 0.524 0.580 0.498 0.559 0.630 0.692 0.582 0.652 0.542 0.618 0.597 0.654 0.557 0.621 0.523 0.593 4.00 0.684 0.656 0.632 0.657 0.634 0.613 0.631 0.612 0.594 0.727 0.693 0.664 0.686 0.659 0.635 g GE Lighting 5.00 0.703 0.679 0.657 0.675 0.655 0.637 0.649 0.632 0.617 0.749 0.720 0.694 0.706 0.683 0.661 51 MULTILITE System 6000 MULTILITE System 6000 is an extremely cost-effective single lamp (Ø 60 mm) lighting system specially made to facilitate the design of modern lighting schemes. Manufactured of aluminium, modules and joints of the same section, bringing continuity to the entire installation. The modular design of the system and wide variety of light sources available make it possible to create an infinite variety of application solutions that are ideal for meeting the varied demands of offices, banks, shops, libraries, etc. Cat. No. 8190 Cat. No. 8189 Cat. No. 6187 Cat. No. 6171 Cat. No. 6170 Cat. No. 6169 Cat. No. 6183 Cat. No. 8186 Cat. No. 6169 Cat. No. 6184 Cat. No. 6176 Cat. No. 6172 Cat. No. 6174 Cat. No. 6175 Cat. No. 6178 Cat. No. 6173 WHITE: RED: BLACK: g GE Lighting 52 RAL 3000 RAL 9005 (code WH) (code RD) (code BK) MULTILITE Systema 6000 Technical Characteristics Modules: extruded aluminium with stoved paint finish in three standard colours. End caps and joints: die cast aluminium with internal connectors; stoved paint finish in three standard colours. Internal reflectors: mirror-finish pre-anodised 99.99% pure aluminium. Diffusers: methacrylate diffuser with internal longitudinal prismatic reeding. Louvre: polycarbonate. Compliance with standards: IEC 34.21 – EN 60598-1. Type Length (mm) Weight (kg) Pack Qty. Product Code Wired module with power factor correction for one T8 fluorescent lamp. Cat. No. 6001 Class: I 230V 50Hz Ø 60 IP 20 IP 40 with diffuser Cat. No. 6151 6001 118 WH 1200 1,50 1 38255 6001 118 RD 1200 1,50 1 38256 6001 118 BK 1200 1,50 1 38257 6001 136 WH 1800 2,00 1 38258 6001 136 RD 1800 2,00 1 38260 6001 136 BK 1800 2,00 1 38261 6001 158 WH 2100 3,00 1 38263 6001 158 RD 2100 3,00 1 38264 6001 158 BK 2100 3,00 1 38265 Without lamp. Module for 2x50W 12V halogen lamps with GY6.35 cap, complete with 230V 50Hz electromagnetic transformer. Cat. No. 6015 Class: I IP 40 230V 50Hz Ø 60 6015 250 WH 600 1,30 1 38371 6015 250 RD 600 1,30 1 38372 6015 250 BK 600 1,30 1 38373 Without lamp. Module of 230V electrified track for Guzzini, Erco, Staff, Hoffmeister and Nokia luminaires (not included). Cat. No. 6018 Class: I 230V 50Hz Ø 60 6018 WH 1500 2,60 1 38266 6018 RD 1500 2,60 1 38267 6018 BK 1500 2,60 1 38268 Module for linear halogen lamps with R7s cap. Complete with protective front glass Cat. No. 6166. Cat. No. 6022 Class: I IP 40 230V 50Hz Ø 60 6022 WH 300 0,50 1 38272 6022 RD 300 0,50 1 38273 6022 BK 300 0,50 1 38274 Without lamp. Emergency lighting module for fluorescent lamp with EES unit for permanent illumination (duration 1 h). Cat. No. 6030 Class: I 230V 50Hz Ø 60 IP 40 with diffuser Cat. No. 6151 6030 118 WH 1500 1,00 1 38276 6030 118 RD 1500 1,00 1 38280 6030 118 BK 1500 1,00 1 38281 Without lamp. WH = white RD = red BK = black g GE Lighting 53 MULTILITE Systema 6000 Length (mm) Type Weight (kg) Pack Qty. Product Code Structural compensation module (can be opened for inspection), complete with reduction rings for ends. Cat. No. 6100 Ø 60 6100 300 WH 300 0,40 1 38283 6100 300 RD 300 0,40 1 38284 6100 300 BK 300 0,40 1 38285 6100 600 WH 600 0,70 1 38286 6100 600 RD 600 0,70 1 38287 6100 600 BK 600 0,70 1 38289 6100 1200 WH 1200 1,20 1 38290 6100 1200 RD 1200 1,20 1 38291 6100 1200 BK 1200 1,20 1 38292 6100 1800 WH 1800 1,70 1 38293 6100 1800 RD 1800 1,70 1 38294 6100 1800 BK 1800 1,70 1 38295 6100 2100 WH 2100 2,00 1 38296 6100 2100 RD 2100 2,00 1 38297 6100 2100 BK 2100 2,00 1 38298 1 38299 Reduction ring for ends (necessary when cutting structural modules), Cat. No. 6101 6101 Ø 60 Type With Pack Product Luminaire Qty. Code Type Clip-fit metallized polycarbonate louvre. 360° Ø 60 40 37 120 g GE Lighting Cat. No. 6170 24/1 38302 6170 WH 25/1 38320 6149 4 1 x 36 12/1 38305 6170 RD 25/1 38322 6149 5 1 x 36 10/1 38307 6170 BK 25/1 38323 Ø 60 17 End cap complete with terminal block and power supply cable clamp. Cat. No. 6171 8150 2 1 x 18 24/1 38308 8150 4 1 x 36 12/1 38309 8150 5 1 x 36 10/1 38310 70 17 Ø 60 6171 WH 25/1 38324 6171 RD 25/1 38325 6171 BK 25/1 38326 6172 WH 15/1 38327 6172 RD 15/1 38328 6172 BK 15/1 38329 6173 WH 10/1 38330 6173 RD 10/1 38331 6173 BK 10/1 38332 Clip-fit metacrylate diffuser, increases protection level from IP 20 to IP 40. Rotating straight joint. Cat. No. 6151 Cat. No. 6172 6151 2 1 x 18 8/1 38312 8151 4 1 x 36 8/1 38313 8151 5 1 x 36 8/1 38314 70 Ø 60 36 Straight joint for connecting System 6000 to System 8000, complete with internal connectors. Horizontal/vertical 90° joint. Cat. No. 6169 Cat. No. 6173 6169 WH 10/1 38316 6169 RD 10/1 38317 6169 BK 10/1 38318 80 Ø 60 WH = white RD = red BK = black 54 Code 1 x 18 Cat. No. 6150 Ø 60 Product Qty. 6149 2 Clip-fit opal polycarbonate louvre. Ø 60 Pack End cap. Cat. No. 6149 Ø 60 With Luminaire MULTILITE System 6000 Type With Pack Product Luminaire Qty. Code Type With Pack Product Luminaire Qty. Code 50/1 38345 Horizontal/vertical “T” joint. 80 Cat. No. 6174 100 Ø 60 30 60 6174 WH 6/1 38333 6174 RD 6/1 38334 6174 BK 6/1 38335 Wall-mounting bracket. Cat. No. 6184 100 6184 Ø 50 Ceiling suspension set complete with 2m steel cable, mounting pin and ceiling rose. Horizontal/vertical “X” joint. 100 2000 Cat. No. 6175 100 Ø 60 Cat. No. 8186 6175 WH 5/1 38337 8186 WH 40/1 38226 6175 RD 5/1 38338 8186 RD 40/1 38227 6175 BK 5/1 38339 8186 BK 40/1 38228 90° ÷ 270° adjustable horizontal/vertical joint. Cat. No. 6176 80 80 90°÷ 270° Ø 60 6176 WH 10/1 38340 6176 RD 10/1 38341 6176 BK 10/1 38342 Static ceiling mounting spacer. Cat. No. 6187 Ø 50 Ø 75 Ø 42 8187 40/1 38346 Power supply set complete with mounting pin, terminal block, large ceiling rose and 3 x 1,5 mm 2 power supply cable extendible to 2m. 2000 60 30 Cat. No. 8189 Internal straight joint for connecting modules. 8189 WH 10/1 38233 Cat. No. 6178 8189 RD 10/1 38234 8189 BK 10/1 38235 6178 30/1 38343 3 x 1,5 mm 2 power supply cable extendible to 2m. 2000 Ø 50 Cat. No. 8190 Mid-suspension bracket (excluding cable). 8190 WH 12/1 38081 Cat. No. 6183 8190 RD 12/1 38239 8190 BK 12/1 38082 6183 60/1 38344 Electrical connection All ready-wired modules feature a four-pole terminal block at both ends suitable for hard wire or flexible cables with a section of up to 2.5 mm2. L1 = module power supply through line. L2 = through line for separate switching only. N = neutral through line. Control gear: 230V 50Hz, heat-resistant cables with section of 1.5 mm2. Mechanical connection Straight extruded aluminium modules are connected to one another using accessory Cat. No. 6178. WH = white RD = red BK = black g GE Lighting 55 MULTILITE System 3000 MULTILITE System 3000 has been specially designed for innovative lighting solutions; unlike conventional systems, it is able to form continuous installations without a break between one fluorescent lamp and the next, as well as offering the possibility of combining direct and indirect lighting in the same module. Manufactured entirely of aluminium, the modular design and wide choice of light sources available offer an infinite variety of application solutions, perfect for offices, banks and shops, etc. End caps, joints and suspension fittings are the same as those used in System 6000. All 3 systems – 3000, 6000 and 8000 ñ can be combined in a single installation. Cat. No. 8190 Cat. No. 8189 Cat. No. 6171 Cat. No. 6187 Cat. No. 6170 Cat. No. 3170 Cat. No. 6169 Cat. No. 3169 Cat. No. 6183 Cat. No. 8186 Cat. No. 6169 Cat. No. 6184 Cat. No. 6176 Cat. No. 6172 Cat. No. 6174 Cat. No. 6178 Cat. No. 6175 Cat. No. 3178 Cat. No. 3180 Cat. No. 6173 WHITE: BLACK: g GE Lighting 56 RAL 9005 (code WH) (code BK) MULTILITE System 3000 Technical Characteristics Modules: extruded aluminium with stoved paint finish. End caps and joints: die cast aluminium complete with internal connectors with paint finish. Cat. No. 3170 in plastic. Internal reflectors: 99.99% pure pre-anodised aluminium with mirror-finish. Diffusers: methacrylate with internal longitudinal prismatic reeding. Louvre: polycarbonate. Compliance with standards: IEC 34.21 – EN 60598-1. Type Length (mm) Weight (kg) Pack Qty. Product Code Wired module with power factor correction for direct lighting with one T8 fluorescent lamp. Cat. No. 3001 Clase: I 230V 50Hz 100 120 IP 20 IP 40 with diffuser Cat. No. 3151 3001 118 WH 610 1 38374 3001 118 BK 610 1 38347 3001 136 WH 1220 1 38375 3001 136 BK 1220 1 38348 3001 158 WH 1520 1 38376 3001 158 BK 1520 1 38349 Without lamp. Wired module with power factor correction for direct lighting with two T8 fluorescent lamps. Cat. No. 3002 Class: I 230V 50Hz 100 120 IP 20 IP 40 with diffuser Cat. No. 3151 3002 218 WH 610 1 38377 3002 218 BK 610 1 38350 3002 236 WH 1220 1 38378 3002 236 BK 1220 1 38351 3002 258 WH 1520 1 38379 3002 258 BK 1520 1 38352 Without lamp. Wired module with power factor correction and louvre (illuminance < 200 cd/m2 for vertical angles above 60°) for one T8 fluorescent lamp. 100 120 Cat. No. 3004 Class: I 230V 50Hz IP 20 IP 40 with diffuser Cat. No. 3151 3004 136 WH 1650 1 38380 3004 136 BK 1650 1 38381 3022 WH 1 38382 3022 BK 1 38383 Without lamp. Module for one 300W linear halogen lamp with R7s cap. 100 Cat. No. 3022 Class: I IP 20 230V 50Hz 120 Without lamp. Wired module with power factor correction for two fluorescent lamps, complete with EES on one lamp for permanent lighting (duration 1 h). 100 120 Cat. No. 3030 Class: I IP 20 230V 50Hz 3030 236 WH 1220 1 38384 3030 236 BK 1220 1 38353 Without lamp. Structual compensation module (can be opened for inspection), complete with reduction pieces for ends. Cat. No. 3100 100 120 3100 300 WH 300 1 38385 3100 300 BK 300 1 38354 3100 610 WH 610 1 38387 3100 610 BK 610 1 38355 1 38356 Reduction piece for ends (necessary when cutting structural modules), Cat. No. 3101 3101 WH = white BK = black g GE Lighting 57 MULTILITE System 3000 Type 100 With Pack Product Luminaire Qty. Code Modular clip-fit polycarbonate louvre L 304 mm with metal finish. Number of louvres per fitting: 1 - 2 x 18W: 2 pcs; 1 - 2 x 36W: 4 pcs; 1 - 2 x 58W: 5 pcs. 3149 100 20/1 100 38357 Modular clip-fit opal polycarbonate louvre L 304 mm. Number of louvres per fitting: 1 - 2 x 18W: 2 pcs; 1 - 2 x 36W: 4 pcs; 1 - 2 x 58W: 5 pcs. 8150 2 40 38358 Code 3170 WH 30/1 38390 3170 BK 30/1 38363 20 Cat. No. 3170 Straight internal joint for connecting modules without breaks. 3178 40/1 38364 Clip-fit plastic joint-cover fins for use with accessories Cat. No. 6173. Cat. No. 3151 120 Product Qty. Cat. No. 3178 20/1 Clip-fit methacrylate diffuser, increases protection level from IP 20 to IP 40. 100 120 3 Cat. No. 3150 120 Pack Plastic end cap. Cat. No. 3149 120 With Luminaire Type 8151 2 1-2 x 18W 4/1 38359 Cat. No. 3180 8151 4 1-2 x 36W 4/1 38360 3180 WH 15/1 38391 8151 5 1-2 x 36W 4/1 38361 3180 BK 15/1 38365 Straight joint for connecting System 8000 to System 3000. Cat. No. 3179 Die-cast end cap for joints. 100 18 120 Cat. No. 3169 3179 WH 38046 3169 WH 15/1 38388 3179 RD 38048 3169 BK 15/1 38362 3179 BK 38049 Electrical connection All ready-wired modules are fitted with 5-pole terminal blocks at both ends suitable for hard or flexible cables with a section of up to 2.5 mm2. L1 = module power supply through line. L2 = through line for separate switching only. L3 = through line for separate switching only. N = neutral through line. Control gear: 230V 50Hz, heat-resistant cables with section of 1.5 mm2. Mechanical connection Straight extruded aluminium modules are mechanically inter-connected by accessory Cat. No. 3178. The straight modules are mechanically connected to the accessories (curved, T and X joints) by accessory Cat. No. 3169 (joint end cap). NB: Accessories are the same as those in System 6000 (6170 – 6171 – 6172 – 6173 – 6174 – 6175 – 6176 – 6178 – 6183 – 6184 – 6187) and System 8000 (8186 – 8189 – 8190). g GE Lighting 58 WH = white BK = black Applications of MULTILITE, designed by Europic software System 8000 System 6000 System 3000 g GE Lighting 59
Similar documents
2D Compact Fluorescent Lamps
Autonomous luminaire for emergency lighting for permanent operation, with built-in recharge unit, sealed batteries and low-loss ballast. The fitting is powered by mains and operated by a remote swi...
More informationGE Lighting GE Lighting
maintenance costs. Body and cover: bonderised cold rolled 5/10 mm sheet steel with white epoxy-polyester powder paint finish. The cover is clipmounted to the body. Lampholder: polycarbonate, fitted...
More informationCATALOGUS DEEL 1
Candle - twisted Lamps E14 Clear Philips Cat. no. Cat. no. Voltage
More information