A. HOW TO USE THESE INSTRUCTIONS A. INSTALLATION INSTRUCTIONS VITREOUS CHINA TOUCHLESS
Transcription
A. HOW TO USE THESE INSTRUCTIONS A. INSTALLATION INSTRUCTIONS VITREOUS CHINA TOUCHLESS
INSTALLATION INSTRUCTIONS VITREOUS CHINA TOUCHLESS A. HOW TO USE THESE INSTRUCTIONS A. · Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. · All information in these instructions is based upon the latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. · These instructions contain important care, cleaning, and warranty information - please leave instructions for the consumer. · B. NOTES B. · · · · · · · · TM URINAL K-4915T · · Observe all local plumbing and building codes. Urinal flushes efficiently with less than 0.8 gallon of water. Stop Valve has a 1/2" NPT inlet supply conection. Fixture dimensions are nominal and conform to tolerances by ANSI Standard A112.19.2M. C. REQUIRED TOOLS AND MATERIALS C. · · · · · · · · · · · · Open end/adjustable wrenches Supply piping and connectors Tape measure Thread sealant tape Basin Wrench Screwdriver D. ROUGHING-IN 3 1/2" NPT A112.19.2M / D. Turn off cold water supplies. Install or relocate supply tubing and waste pipe to conform to roughing-in dimensions. See Fig. #1 for roughing-in dimension requirements. 1 * Urinal complies with ADA requirement when rim is mounted no highter than 17" from finished floor. * 432mm 528137 85788-T01-A -1- 2004 ã ã Copyright Kohler China Ltd., 2004 146 1/2" N.P.S. INLET FOR STOP VALVE 2"N.P.S. TAP 20mm 12mm 362mm 464mm 305mm 22-32mm 70mm 603mm 10mm 0 610mm + 1029mm TO FLOOR 838mm 152mm OUTLET DETAILS 76mm 533mm 2"N.P.S. TAP *610mm Fig. #1 1 NOTE: Roughing-in dimension requirements for supply tubing as shown. Supply tubing is 22-32mm out of the wall. Otherwise, stop valve can not be installed and adjusted properly. : 22-32mm INSTALLATION A. MOUNT URINAL Hangers See Fig. #2 Install hangers per roughing-in illustration. Apply sealant tape to pipe threads and install female collar on waste pipe. Place washer on female collar with beveled surface facing away form collar. Collar Install Urinal. Secure urinal to female collar with screws and washers. Apply Sealant Tape CAUTION: Risk of chipping or breaking urinal. Do not overtighten screws. Washer NOTE: Do not caulk top surface of urinal. Caulk may prevent tank cover from seating properly. A. Fig. #2 2 2 : 85788-T01-A -2- B. CONNECT SUPPLY See Fig. #3 Apply sealant tube to pipe thread and install stop valve assembly and tighten connection. Clamp Nut Stop Valve Control Unit NOTE: Supply stop outlet should face left side of tank when tighten. It is recommended that a temporary rubber or plastic hose is attached to the stop valve, and the water supply line should be flushed clean of dirt and debris. Plug seal ring into inlet hole of urinal. Remove the nuts for fixing the bezel and the two clamps. NOTE: While removing the nuts, avoid dropping bezel, which may break urinal. Sensor Window Put the sensor window into the bezel, fix sensor window with the clamp and the nuts. NOTE: Tighten the nuts slightly to provent sensor window from breaking. (Do not over tighten the nuts.) Place the control units connected with sensor window in the positions as shown. Bezel Fig. #3 3 B. 3 : : : 85788-T01-A -3- See Fig. #4 Connect the inlet of valve assembly to inlet pipe with the washer and G1/2" nut. Inlet Pipe Valve Ass. Connect the outlet of valve assembly to outlet pipe 1 with the washer and the nut. Connect outlet pipe 1 to outlet pipe 2 with the washer and the nut. For adjusting, do not tighten its. Outlet Pipe 2 2 Outlet Pipe 1 1 4 G1/2" Fig. #4 4 1 1 2 See Fig. #5 Put the valve assembly and the pipes into the tank of urinal. Plug the other end of outlet pipe 2 into the sealing washer. Adjust the distance of outlet pipe 1 and outlet pipe 2, then connect the other end of inlet pipe to stop Valve with the washer and G1/2" nut and then tighten them. Adjust the nuts, make sure that pipes, valve assembly and stop valve are in the correct position, then tighten all nuts. 5 2 1 2 Fig. #5 5 G1/2" See Fig. #6 Turn on stop valve, Inspect pipes for leakage in not flushing. Connect control unit lead to valve assembly lead. Remove the battery lid from back of control unit. (Do not lose the screws.) Put alkaline batteries into the battery holder, then cover the lid and tighten screws, otherwise the batteries may be affected by dampness. NOTE: Observe battery polarity markings on battery holder assembly. 6 Connector ( ) Fig. #6 6 ( ) : 85788-T01-A -4- The state of distance adjustment has been last about 8 minutes after close the electric circuit, no flushing in this situation. Sensor light of control unit will not flush when no user, If it flashing continuously, this indicates that the room is too small or there are fixtures nearby. Adjust the induction distance referring to "Adjust the Induction Distance". The sensor will begin working normally after about 8 minutes if flushing water volume is not enough, reset the flushing time referring to "Operation State Setting" in order to changhing the flushing water volume. If flushing water volume is too small, remove restrictor from valve assembly. (Ensure that all joints are watertight.) C. INSTALL TANK COVER See Fig. #7 Open tank cover lock package and remove contents. Place tank cover upside down on a protected surface to prevent damage to tank cover finish. Place hooks inside tank cover. Hook NOTE: If necessary, engage the hooks facing opposite the direction illustrated. Using a 5/8" wrench, assemble and tighten nut, washer and lock nut on both sides of urinal. Screw CAUTION: Risk of chipping or reaking urinal. Do not overtighten screws on urinal. Nut Place tank cover on urinal. Using supplied locking tool, install and tighten locking bolts. Check that tank cover is properly locked. Washer Sleeve C. Fig. #7 7 7 5/8" : 85788-T01-A -5- USING A. BATTERIES CHANGE A. When the batteries are nearly exhausted, the battery indicator lamp will flash continuously if somebody uses the urinal (The maximum times of glisten are 20 times), means that it need to change the batteries. And the batteries are exhausted, the battery indicator lamp will flash every 2 seconds, the sensor stop working, until the new batteries are changed. Take off the lid, then change the batteries. Pay attention to the pole of the batteries and do not use the new and old batteries at the same time. Needn't reprogram after changing the new batteries. ( 20 ) 2 B. CLEANING THE FILTER B. If flushing water volume is reduced, the filter must be cleaned. Remove the nut and take out of the filter. Put it back after cleaning. NOTE: Turn off the stop valve before cleaning. : C. ADJUST THE INDUCTION DISTANCE C. See Fig. #8 The induction distance is set to maximum and usually will not require adjustment. If the toilet is small or there are other fixtures nearby, under these circumstances, it may need adjustment. Take out the stopper from the control unit; adjust the distance potential screw as shown. After setting, plug the stopper tightly. 8 NOTE: For easy distance adjustment, during the initial 10 minutes that batteries are inserted, the unit is set to operate in adjustment mode and will not flush, but the lamp will flash when a user is detected. If adjustment takes longer than 10 minutes, remove and reinsert batteries. : NOTE: The scope of the screwdriver which is used to adjust the induction distance should not be larger than 3.5 70mm, so as not to damage the potenpiometer. : 3.5 (Increase) (Decrease) Fig. #8 8 85788-T01-A -6- 70mm D. OPERATION STATE SETTING D. See Fig. #9 Operation state can be set by using the switch, According to the demand, set the state following the table, After setting, plug the stopper tightly. Flush State to Set Sw1 Sw1 ON OFF 1 . Flush Yes No st 9 SW1 SW1 Detection Duration to Set Sw2 Sw2 Detection Duration ON OFF ON OFF SW2 ON OFF 4-6sec. 1-3sec. SW2 4-6 2nd. Flush Duration to Set Sw3, Sw4 Sw3 Sw4 OFF OFF ON 1-3 SW3, SW4 2nd. Flush Duration SW3 SW4 3 sec. OFF OFF 3 OFF 6 sec. ON OFF 6 OFF ON 9 sec. OFF ON 9 ON ON 12 sec. ON ON 12 NOTE: This product has 1st. Flush function. The nd detection duration is about 5 sec. 2 . Flush duration has been set by normal flushing water volume required. : ON 1 2 3 4 Fig. #9 9 85788-T01-A -7- 5 SENSOR SPECIFICATION Power Supply 4 no.s of AA sized alkaline batteries Power Consumption The batteries can be used about two years (4000 times a month) Induction Control Mode 4 5 ( 70cm From the sensor window (adjustable), by 30 30cm2 white paper being the reflector 30 Detection Duration Approx 5 seconds (adjustable to 2 seconds) 5 4000 ) 30cm2 70cm ( 2 1st. Flush (adjustable to no 1st. flush) ( 2nd. Flush (flushing duration adjustable) ( Flushing Water Volume Not more than 3L 3L Deodorization Flushing One forced flushing will be conducted if the urinal is being used continuously for 2 minutes. 2 Starting Pressure 0.05-0.7MPa. 0.05-0.7MPa. Operation Temperature Ambient (water) temperature of 1 -55 1 Recommended water supply pressure (dynamic pressure at inlet): 0.1-0.55MPa. 85788-T01-A 4) Infrared reflective Fuzzy power-saving control Induction Distance Flushing Mode (LR6 ( -8- ( ) ) ) ) -55 ( ): 0.1-0.55MPa 1 -55 ) TROUBLESHOOTING Make sure to complete the prcedures following before asking for repair: SYMPTOMS PROBABLE CAUSES No flushing (indicator lamp fails to work) 1. No batteries or batteries reversed. 2. There are other objects are being detected. CORRECTIVE ACTION 3. Dirty sensor window. 1. Check the batteries. 2. Remove objects or adjust the induction distance. 3. Clean the sensor window. Indicator lamp flashing but little or no water when user or object detected 1. Initial 8 minutes. 2. Stop Valve is not opened. 3. Low water pressure. 4. Dirty filter. 1. Wait 8 minutes. 2. Turn on the Stop Valve. 3. Increase water supply pressure. 4. Clean the filter or remove restrictor. Water does not stop indicator lamp does not flash The valve is clogged. Clean fliter and cause unit to flush several times. If filter clogs again, turn off stop valve and flush water supply line clean of Replace the batteries. Battery indicator lamp flashing Batteries are exhausted. continuously and no water After the check above, the problem still exist, contact us through Dealer. ( ) ( ( ) 1. 2. 1. 2. 3. 3. 1. 2. 3. 4. 1. 2. 3. 4. ) CONSUMER RESPONSIBILITIES 1. Urinal is designed for use with potable water. Avoid water that includes a lot of contaminants or with acid/alkali water and impure water. 2. If you live in a hard water area, make certain that the holed in the toilet rim are kept clean to ensure proper bowl flushing, Toilet bowl cleaners should be used at least once a week. Use a long-handled brush to clean the rim holes, and to clean as far into the trap as possible to prevent mineral deposits from forming. 3. Most toilet bowl cleaners are not harmful to the surface of the urinal, Please follow the bowl cleaner manufacture's instructions carefully. 4. Do not use abrasive cleaners for china surface. 5. Do not directly flush the wire connector of sensor with water. 6. Do not make Sensor Window near strong ultraviolet and electromagnetism. 7. Keep the sensor window clean. Do not attack the sensor. The sensor cover can be cleaned by the soft rag. (with neutral liquid detergent). Do not use the eradicator, abrasive powder or the oil, acid or alkali liquid detergent. Do not sprit the air freshener, disinfectant or the other kinds of odious smell remove, clean organic liquid to the sensor directly. 85788-T01-A 1. 2. 3. 4. 5. 6. 7. -9- 8 LIMITED ONE-YEAR WARRANTY Plumbing Fixtures and Fittings Limited One-year Warranty Kohler plumbing fixtures and fittings are warranted to be free of manufacturing defects. This product is warranted for one year from date of purchase. Kohler China will be responsible for any problems caused by manufacturing defects provided with the invoice. Kohler China will, at its election, repair, replace or make appropriate adjustment where Kohler China inspection discloses any such defects occurring in normal usage within one year after purchase. Implied warranties including that of merchantability and fitness for a particular purpose are expressly limited in duration to the duration of this warranty, Kohler China disclaims any liability for special, incidental or consequential damages. Damages to the product caused by misuse, abuse and installation that is not in accordance with the owner's manual are not covered by this warranty. To obtain quick warranty service, please contact your dealer, or write to Kohler China. (Original sales receipt must be provided as the proof of purchase.) ( ( Kohler China Investment Company Ltd. Central Customer Service Center 19/F, Shanghai Square, 138 Huai Hai Road, Luwan District, Shanghai, PRC Zip Code: 200021 ) 138 19 200021 This is our exclusive written warranty. 85788-T01-A ) -10- SERVICE PARTS PAGE TM VITREOUS CHINA TOUCHLESS Nut Filter Nut Outlet Pipe 1 1 URINAL K-4915T 82372** Cover Washer Nut G1/2" O-Ring O Nut G1/2" Restrictor Nut Washer Inlet Pipe Washer Screw Washer Outlet Pipe 2 Stop Valve Ass. 2 Valve Ass. Connector Sealing Washer Cover Sensor Window 97553-FK SENSOR 21251 Washer Stopper 76636 Nut Connector Screw Control Unit 74250 Clamp 32935 Nut 75412 Stud 74250 Clamp 51537 Wrench 51571** Sleeve 51588 Washer 51570 Nut 51540** Screw 51572 Washer 28648 Screw 49932 Washer 73975** Tube 64512 Hanger 51676 Hook 73203** Bezel 51543** Washer 53405 Collar 53407** Screw 53149-S Beehive 53410 Washer 53370** Cross Bar ** ** Color code must be specified when ordering. 85788-T01-A -11- 53407** Screw