PEJABAT DAN STOR KASTAM MELAKA
Transcription
PEJABAT DAN STOR KASTAM MELAKA
PROJEK RMK 10 PEJABAT DAN STOR KASTAM MELAKA 1 PENGENALAN Nama Projek : Pejabat dan Stor Kastam Melaka Pelanggan : Kementerian Kewangan Peruntukan Asal : RM 20 Juta Siling Kos Projek : RM 10 Juta Tarikh Mula Daftar Projek : 15.04.2011 Tarikh Jangka Tender : 2 September 2011 Kaedah Pelaksanaan : Konvensional Dalaman, IBS 2 PENGENALAN Floor Area : 2608.59 m² Mechanical Cost : RM 1,090,000.00 (Airconditioning system, Fire fighting system and pumps) Mechanical System : Air- Conditioning, Fire Fighting, Cold Water and Sanitary 3 4 Site Plan 5 Aras Bawah 6 Aras Satu 7 Aras Dua 8 Aras Bumbung 9 DESIGN CONCEPT Standards EPU Guideline 2008 Value Management & Value Engineering Green Technology Cost Limitation Maintainability Client’s need Functionality Architect Layout Design Sustainability MS 1525 : 2007 UBBL 1984 Mechanical System Design and Installation Guidelines 2011 Syarikat Air Melaka Bhd. Specification Bilik Kebal, dll. Safety 10 AIR-CONDITIONING QS – Cost Estimation RM 800,000.00 Architect – AHU room size, ceiling space requirement, Space for outdoor unit Structure – Loading for a/c units Electrical – Electrical loading / phase 11 AIR-CONDITIONING Cost Estimation for A/C System Option Cost Estimation (RM) Others a) Not alligned with EPU guideline Fully split unit system 650,000 Fully MSU (VRF/VRV)system 850,000 a) High cost (limited budget) Split ducted & Split unit system 650,000 a) No suitable area for placing outdoor for split unit Split ducted & MSU(VRF/VRV) system 700,000 Mini Chiller system 850,000 b) High maintenance (cost burden to client) a) Reasonable cost b) Outdoor unit can be located on the roof (max distance 150m) a) High cost (limited budget) 12 AIR-CONDITIONING Centralized system – Split Ducted Decentralized system – Multi Split (VRF) 13 AIR-CONDITIONING Approximate AHU Room Dimension and Ducting Requirement Maximum Total A/C Area PerZoning = 580m² 14 AIR-CONDITIONING A/C Zoning Aras Bawah 15 AIR-CONDITIONING A/C Zoning Aras Satu 16 AIR-CONDITIONING A/C Zoning Aras Satu 17 AIR-CONDITIONING Schematic Concept for Centralized System – Split Ducted 18 AIR-CONDITIONING Schematic Concept for Decentralized System – MSU Ducted 19 AIR-CONDITIONING Green Technology / Energy Efficiency Indoor air condition design based on MS 1525 Separate air distribution system Temperature control CO2 monitoring and control (CO2 sensors) Refrigerant pipe insulation (preinsulated refiregerant pipe and duct) Environmental friendly refrigerant gasses (R-410a) No painting usage for a/c pipes 20 FIRE FIGHTING QS – Cost Estimation RM 300,000.00 Architect – Hose Reel Compartment, Hose Reel Tank and Pump, MFAP Structure – Loading for Hose Reel Tank Electrical – Electrical loading / phase for pump 21 FIRE FIGHTING Fire Fighting System Selection 22 FIRE FIGHTING Schematic Concept for Hose Reel System 23 FIRE FIGHTING Clean Agent System 24 FIRE FIGHTING Green Technology / Energy Efficiency High efficiency motors/pump Usage of soft starter for motors Environmental friendly clean agent gas (Argonite, Pyroshield) 25 COLD WATER & SANITARY Architect – Space for Domestic Tank and Suction Tank Structure – Loading for Suction and Domestic Tank Electrical – Electrical loading / phase for pump Civil – Location for Inspection Chamber (IC) 26 COLD WATER & SANITARY Schematic for Cold Water system 27 COLD WATER & SANITARY Schematic for Cold Water system 28 COLD WATER & SANITARY Green Technology / Energy Efficiency High efficiency motors/pump Usage of soft starter for motors 29 30 Extinguishing system • Hose Reel System • Portable Extinguisher • Clean agent Fire Alarm system • Break Glass • Detectors (stor area) 31 Schematic 32 Design Concept SISTEM COLD WATER & SANITARY • Refer standard from Syarikat Air Melaka Berhad (SAMB) 33 Storage Tank capacity of 5000 gallon located on the roof Pump ( Hydropneumatic and Suction pump) Pipe (ABS and UPVC) 34 Design Concept Green Technology • System design according to MS 1525:2007 •Indoor condition based on MS 1525 •Dry bulb temperature between 23°C – 26°C •Relative humidity 55% - 70% •Air movement 0.15m/s – 0.50% •Environment friendly refrigerant gases and cleant agents •High efficiency motors •Central monitoring and management system 35 • Temperature control • CO2 Monitoring & Control (CO2 sensors) • Pipe Insulation(refrigerant pipe and duct) • Separate air distribution system 36 High Efficiency Pump System • Cold Water System Booster Pump Hydropneumatic Pump 37 High Efficiency Pump System • Pump system characteristic – High efficiency – Variable speed for precise control – Space saving ( vertical pump) – Soft starter (power utilization) 38 Central Monitoring and Management System Air-Conditioning Monitor and control indoor unit Zoning & grouping capabilities Scheduling option Fire Fighting Main fire alarm panel Cold water Pump control panel 39 Sustainability • Pre-insulated refrigerant pipe & Pre-fabricated duct • Zoning the air conditioning system according to day and night operation. • Minimise painting and adhesive usage 40 Functionality • Outdoor unit located on the roof top • Operation according to end user requirement • Independent operation system for non-simultaneous room (meeting room ,operation room) • Centralized controller system located at control room. • IC and Manhole location • Sizing of AHU rooms and Mechanical Room • Operation of systems during fire mode operation 41 Safety Out door located at roof top - Disediakan laluan khas melalui tangga ke kawasan bumbung dan pemasangan louvers fencing di sekeliling unit outdoor. High/Low pressure protection compressor Compressor & Motor current overload protection Fire rated duct, AHU doors. Hose reels located in prominent position at each floor level along escape routes/exit doors/staircase Central monitoring system 42 Maintainability • AHU - Ruang bilik yang mempunyai kelegaan sekeliling unit peralatan AHU (min 1m) dan pintu bilik AHU mudah untuk di access drp ruang lobi. • Out door located at roof top - access by staircase and double leaf door provided • Lokasi FCU ceiling conceal - Ditempatkan dalam siling pada kawasan yang tidak melibatkan laluan kerja atau ruang pejabat. 43